Leica Leica VT1200S manual Installation, Standard Scope of Delivery for the VT1200

Page 14

4.

Installation

 

4.1 Standard Scope of Delivery for the VT1200

 

 

VT1200 basic instrument

0481 42065

 

1 control panel

0481 43395

 

1 toolset:

 

 

- 1 Allen key, size 3.0

0194 04764

 

- 1 Allen key, size 6.0

0222 04141

 

- 1 cryo-manipulator

0462 28930

 

- 1 replacement fuse T 1A

6943 01000

 

1 set of power cables:

 

 

- 1 power cable "D"

0411 13558

 

- 1 power cable "USA-C-J"

0411 13559

 

- 1 power cable "UK" ST/BU F-5A

0411 27822

 

1 dust cover (basic instrument), small

0212 43742

 

1 bottle of cyanoacrylate adhesive, contents 10 gr

0371 27414

 

1 Operating Manual for Leica VT1200/VT1200S

0702 37107

 

VT1200 configuration

912000001

 

The above scope of delivery,

 

 

plus:

 

 

Ice bath, complete

0481 42010

 

Buffer tray, (metal) complete

0481 42084

 

VT blades (10x10 Gillette)

0205 42056

When ordering additional accessories, compare the parts received with the parts ordered. If the parts received do not match your order, contact the sales company responsible for your order imme- diately.

14

Operating Manual V1.1 – 05/2007

Image 14
Contents Leica VT1200 Leica VT1200S Page Nussloch Germany Contents Intended Use/Improper Use Symbols in the Text and their MeaningsImportant Notes Qualification of PersonnelSafety General Safety NotesTransport, Unpacking and Setting up Proper handlingElectrical data Instrument CharacteristicsTechnical Data for the VT1200 Dimensions Instrument CharacteristicsTechnical Data for the VT1200S Ambient conditionsGeneral Overview of the VT1200/VT1200S MicroscopeAttachments on dovetail receptacle Blades for the blade holderVT1200 Control Panel LED for feed rate1 VT1200S Control Panel Window edge is set Moves the specimen Upwards as long asInstallation Standard Scope of Delivery for the VT120091200S001 Standard Scope of Delivery for the VT1200S0481 Packing and Setting up the Instrument Packing the instrumentBefore Commissioning the Instrument Working with the Instrument Description of the Typical ApplicationControl Elements on the VT1200 Control Panel Moving the Specimen Receptacle VerticallyBlade Method Blade Forward backSelecting the Sectioning Parameters Starts the sectioning processBlade feed rate Speed LED illumination is switched onControl Element on the Control Panel of the VT1200S Selected amplitude Ampl Saved section thicknessToggling from Auto Toggling from MAN to An audible warning signal soundsWhen these keys are pressed ModeAutomatic mode max μm Adjusting the amplitude fromKey/setting dial Mm in 0.05 mm increments Not possibleWorking with the Instrument Blade forward and Blade Window edge key until the LED Key lights upWard key. Press the 1st cutting Ward key and press 2nd cuttingΜm display is then reset to ProcessAutomatic section thickness Or 100μm by max μm using rotary knobUsing predefined step sizes 1 Stroke Single can be selected MAN with rotary knob 1 forStroke type CUT only single With rotary knob 1. If continuous5 mm/s in 0.5 mm/s increments Installing the Accessories Installing the Ice Bath and Buffer TrayInstalling the Double-walled Buffer Tray Preparing a SpecimenInstalling and Removing the Blade Holder Inserting the Blade Adjusting the Clearance Angle Now return the blade holder to the cutting positionWorking with the Instrument Using the VibroCheck with the VT1200 Operating the VibroCheckNormal operating status is now restored Using the VibroCheck with the VT1200S Operating the VibroCheck Error/INF No Troubleshooting Remark Malfunctions Meanings and TroubleshootingError Messages and Troubleshooting Harm the instrumentReached Panel and keyboard Software updatedInF C2 have differentVibroCheck VibroCheck was Collides with Dirty. CleanDown during installa BladeInstrument is Plug connections are Blocked when RUN is activeNot accepted Negative values Values of more than 1000μm Replacing the Main Fuse Clean using an alcohol-based solution or acetone Cleaning and MaintenanceCleaning the Instrument Blade Buffer traySpecimen plate DisplayExtension Accessories for Standard Specimens Buffer TraySpecimen Plate Lid for covering the buffer trayVibroCheck Blades Microscope, Complete Magnifier, CompleteInstalling the Magnifier Support or Microscope Support 240 V, 50/60 Hz Fiber-optic Illumination, Cold Light Source230-240 V, 50/60 Hz Voltage variant 230V/50/60Hz EC Declaration of Conformity Leica VT1200/VT1200S Microtome with vibrating bladeWarranty and Service WarrantyOperating Manual V1.1 05/2007