Emerson 6081-P instruction manual Hart PollAddress

Page 5

Quick Start

Menu

English Francais

Espanol >>

Deutsch Italiano Portuguese >>

Measure? pH

Redox ORP

Use Preamp in?

Xmtr Sensor

Diagnostics?

On Off

Measure update

rate: 1min

Temperature in?

°C°F

Setup Wireless Network? Yes No

Wireless Network

HART PollAddress

Network ID:

00000

Network Join Key 1 of 4: 00000000

Network Join Key

2 of 4: 00000000

Network Join Key 3 of 4: 00000000

Network Join Key 4 of 4: 00000000

Wireless Network

HART PollAddress

HART Polling

Address: 00

E

Image 5
Contents Model 6081-P Essential Instructions Shipping considerations for wireless products Power ModulesAbout This Document Quick Start Guide Hart PollAddress Menu Tree for Model 6081 pH Wireless Transmitter Model 6081-P pH/ORP Table of Contents CONT’D Iii List of FiguresNumber Title This page left blank intentionally Specifications General Section Description and SpecificationsFeatures and Applications Functional Specifications Specifications WirelessMeasurement update rate 1/sec. to 1/10 min PH Range 0 toFCC and IC Hart CommunicationsTelecommunication Compliance Asset Management Solutions Unpacking and Inspection Section InstallationConsiderations Temperature Element PRE-INSTALLATION SetupReference Electrode Impedance Preamplifier LocationSection Mounting on a Flat Surface Pipe Mounting Installing the Power Module Power Module InstallationSection This page left blank intentionally General Information Section Sensor WiringSensor Wiring This page left blank intentionally This page left blank intentionally Section Intrinsically Safe InstallationThis page left blank intentionally Network Communications Device Network ConfigurationSection Commissioning Verify Operation Display Section Display and OperationScreen a Screen C Screen BInformation Screen Messages KeypadHow the Security Code Works SecurityThis page left blank intentionally Section Operation with Model Off-line and On-line Operation Making Hart related settings from the keypadGeneral Changing START-UP SettingsSection Programming the Transmitter Definitions Choosing and Configuring the Analytical MeasurementPurpose Choose Soln Temp Corr or Sensor Isoptntl Choose MeasurementPurpose Choose Calib or Config Setting a Security CodeProcedure Setting a security code Resetting Factory Calibration and Factory Default Settings Making Hart Related SettingsProcedure Installing default settings Choose ResetTransmitterProcedure Choosing a display screen Selecting a Default Screen and Screen ContrastChoose Default Display Procedure Changing screen contrastProcedure Programming the display timeout Choosing a Display TimeoutIntroduction Section Calibration TemperatureCalibrating Temperature Procedure Calibration pH and ORP SectionCalibration Slope and Offset Choose BufferCal Procedure Auto Buffer CalibrationProcedure Manual TWO-POINT Buffer Calibration Choose Standardize Procedure StandardizationProcedure Entering a Known Slope Value ORP Calibration Preparation of ORP standard solutionsThis page left blank intentionally Overview Section MaintenanceTransmitter Maintenance Cleaning Procedures Frequency of CleaningRejuvenating Reference Electrodes Checking the Reference ElectrodeCalibration ORP Sensor MaintenanceGeneral Calibration FrequencyPower Module Replacement Shipping Considerations Handling ConsiderationsEnvironmental Considerations General Section Return of MaterialThis page left blank intentionally Warranty Specifications subject to change without notice
Related manuals
Manual 16 pages 28.1 Kb