Panasonic WJ-HD100 operating instructions Connections with PS Data Equipment

Page 11
■Connections with PS • Data Equipment

Connections with PS Data Equipment

Camera

Camera In

POWER

ON Manual background

OFFManual background

Camera Out Manual background

Video In

POWER

ON Manual background

OFFManual background

If the cable is locally procured, make sure it is data grade cable suitable for RS-485 communication. A 2- wire twisted pair shielded cable, BELDEN 9406 or equivalent should be used. Pin assignments and data flow are shown below.

 

No.

Name

Data Flow

No.

 

Controller

1

1

GND

 

1

 

 

 

end

 

2

RX(B)

WJ-HD100

WV-CU360

2

 

 

 

1

 

3

RX(A)

WJ-HD100

WV-CU360

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

TX(B)

WJ-HD100

WV-CU360

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

TX(A)

WJ-HD100

WV-CU360

5

 

 

 

 

 

 

 

6

6

 

6

GND

 

6

 

 

 

 

 

 

 

Data Multiplex Unit

Video Monitor

ALARM

ALARM SUSPEND

Data Multiplex Unit WJ-MP204

DATA Port

Video Multiplexer

POWER

ON

OFF

Note:

Set the field rate to

7.5fps or slower when connecting the Camera SW Out signal with the video multiplexer.

CAM SW

 

Rec

 

In

 

Out

 

 

 

Play

 

 

In

 

IN

 

IN

 

OUT

 

OUT

 

 

 

 

AUDIO

CAMERA

VIDEO MONITOR OUT

RS-232CDATA

SW OUT

 

(PLAY)

 

 

 

 

DATA Port

 

Multi Screen

Video In

 

Out

 

 

 

 

 

 

 

DATA Port

Digital Disk Recorder WJ-HD100

 

 

 

(EXT REC) JOG-CLICK JOG-LEFT JOG-RIGHT

G ALARM SEARCH STEP

REW/FF STOP/SETUP PLAY REC G OUT IN PLAY OUT

REC OUT AUTO OFF OUT DISK END OUT OUT IN

G RECALL OUT RECOVER OUT RESET IN

POWER

ON

SIGNAL GND

IN

 

 

 

 

 

OFF

MODE

REMOTE

TIME

SERIES

ALARM

 

 

 

ADJUST

RECORD

 

 

Camera SW

Video In Monitor Out

Out

 

 

DATA Port

 

System Controller

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set the termination to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

ON for the units at both

 

 

 

 

 

 

 

 

 

 

 

 

 

ends of the chain, and to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF for units in the

 

 

 

MODE

 

 

 

 

middle.

System Controller with PS•Data

Capability

PSData equipment must be set up for communication as follows:

Protocol selection: PS DATA

Unit Address: Set an address unique in the chain.

Baud rate, data bit length, parity check, stop bit: Choose the same settings as used for the other equipment in the chain.

Recommended video multiplexers are Panasonic’s WJ-FS series or similar models having specifications as follows.

Switching recognition signal is located within 8H prior to the end of vertical blanking.

A camera switching rate of 4/60 seconds or more is available.

11

Image 11
Contents Model No. WJ-HD100 ENGLISHFRANÇAIS Digital Disk Recorder Operating InstructionsENGLISH VERSION ENGLISH CONTENTSVarious alarm modes FEATURESPREFACE Easy access to the desired recordPRECAUTIONS 5!6!7 !8 Front Viewq w e t y u o!0!1!2!3!4@2 @5 Rear View@1@3@4@6 @7 @8@9 #6#7#8Power Cord #4Alarm Terminal#6Power Switch POWER ON OFF #7Signal Ground SIGNAL GNDPlaces to avoid INSTALLATIONCaution Notes Regarding Installation Mounting in the RackBasic Connection CONNECTIONConnections with PS Data Equipment Series Connection ALARM Alarm Terminal ConnectionRS-232CConnection PS Data ConnectionUnit Address & Initialize Mode Switch SettingAlarm Output Polarity TerminationTurning Off the Power SETUP PROCEDURESPrior to Setup Turning On the PowerCLOCK→ Displaying the SETUP MENUButtons and Dials Used for the Setup SF- 12H Setup Menu SequenceCLOCK→ SKIP&PLAYNOW FORMATTING HDD Initializing All Contents & Setup DataInitializing Setup Data InitializingCLOCK→ WJ-HD100SETUP MENUClock Setup 001 CLOCK Time & Date Type 002 TIME&DATE TYPEStatus Position 006 STATUS POSI Time & Date Display 003 T&D DISPLAYTime & Date Position 004 T&D POSITION Status Display 005 STATUS DISPR-LOWER SYSTEM SETUPHDD FULL Selection 007 HDD FULL Quick Play Mode Selection 101 FWD/REW MODESetting Buzzer ON/OFF 105 KEYLOCK BUZ Password Setup 102 PASSWORD LOCKAuto Erasing 109 AUTO ERASING Reset Pulse Polarity 106 RESET PULSETime Adjusting 107 TIME ADJUSTING Set Time 108 SET TIMERecording Quality 203 REC QUALITY REC SETUPRecording Mode 201 REC MODE Recording Field Rate 202 REC RATENotes on SERIES connection Disk End Mode Setup 204 DISK ENDSTOP CONTINUE ALM CONTINUE SERIESSTOP Disk End Buzzer Setup 205 DISK END BUZZERJog Click Terminal Definition 206 JOG/EXT REC External Recording Mode 207 EXT REC MODEAlarm Buzzer 305 ALARM BUZZER ALARM SETUPAlarm Recording Mode 301 REC MODE Alarm Recording Duration 304 DURATIONMotion Detector Setup 306 VMD SETUP Making Reservations INTERNAL TIMER RECBaud Rate 503 BAUD RATE COMMUNICATION SETUPProtocol 501 PROTOCOL Unit Address 502 UNIT ADDRESSWait Time 507 WAIT TIME SYSTEM INFORMATIONParity Check 505 PARITY CHECK Stop Bit 506 STOP BITWhen a button is pressed in KEY LOCK mode OPERATING PROCEDURESSequence of LCD Displays in operation Alarm RecordingRecording Internal Timer RecordingPower-onRecording Alarm RecordingStep Playback PlaybackNormal Playback Skip PlaybackTime & Date Search Alarm Record SearchPlayback Oldest/Latest Record JUN 9.00 00 Alarm History SearchJUN Alarm OperationSuspending Alarm Input Alarm History SearchCapacity in MB Resetting AlarmCopy to CompactFlash Card ManufacturerBlue.jpg Index.htm Play.htm Folders and FilesHD100 000001 000001.jpg 000002.jpg 000003.jpg Enabling Button Lock Password VerificationPASSWORD Lock/Unlock ButtonsWhat to do TROUBLESHOOTINGPhenomenon CauseGeneral SPECIFICATIONSAlarm Function Standard AccessoriesAPPENDIX Remote Control From System ControllerLoop Connection Recording SetupOperating Procedures SERIES RECORDINGOperating Procedures Series Connection RecordingPlayback Setup1Reception Command 1. Transmission Command2.Response Command Communication ProtocolBasic Operation Command TableAlarm Control Setup ControlMedia Control Miscellaneous ControlData Log Control Inquiry V8QA5548EN Panasonic Canada IncPanasonic Sales Company N0800-4120Reservation for Consecutive Days DEFAULT→ADDENDUM Reservation Past MidnightPlay Mode Display Using a graphics applicationUsing the Viewer.htm Thumbnail Mode DisplayRéservation pendant des jours consécutifs SUPPLÉMENTVERSION FRANÇAISE Réservation après minuitRemarques Utilisation de Viewer.htmAffichage de mode vignettes Affichage de mode de lectureENGLISH VERSION ADDENDUMCLOCK→ WJ-HD100SETUP MENU on page 16, 17 and32 Status Out Terminal on page Stop VMD descriptionReservation Past Midnight Reservation for Consecutive DaysAdditions to page 40, Copy to CompactFlash Card Time and date specific copyThumbnail Mode Display Play Mode Display23:00:00 Notes on alarm operation during copyingSTART JAN01.01V8RA1274CN Panasonic Canada IncPanasonic Sales Company NM0201-2012