The following changes and additions have been applied to the WJ-HD100 Operating Instructions.

Default setting Changes

REC SETUP windows on page 17, 24, 25 and 26:

The default setting for DISK END MODE is changed from [STOP] to [CONTINUE].

The fourth line of text on page 26 is also changed from STOP to CONTINUE well.

Changes

System Info window on Page 17 & 31: VERSION display has been changed.

Folders & Files on page 40: Descriptions are replaced with the following.

In each COPY TO CARD operation, a folder with a 6-digit name is created on the card, for example, 000001, 000002 and so forth. A folder contains files having the [.jpg] or [.htm] extension as shown below.

SYSTEM INFORMATION

HDD

HOUR METER

1000H

 

HDD

CAPACITY

.

GB

DEFAULT

SET

 

VER x.xx(x.xx x.xx x.xx)

HD100

ADDENDUMManual background 000001 000001.jpg 000002.jpg

000003.jpg

Blue.jpg

Viewer.htm

Manual backgroundManual background 000002

Communication Protocol, Setup Control on page 48 has been corrected.

Item

Transmission Command (ASCII)

Response (ASCII)

Parameter (ASCII)

Cursor Moves

DCR:n1n2

DCR

n1=A Right

 

 

 

n1=C Upward

 

 

 

n1=E Left

 

 

 

n1=G Downward

 

 

 

n2=1 Move a step

 

 

 

n2=2 Move multi steps

 

 

 

n1n2=+1 Select parameter(+)

 

 

 

n1n2=-1 Select parameter(–)

 

 

 

n1n2=PD Move to lower layer

 

 

 

n1n2=P+ Move to upper layer (deletion)

 

 

 

n1n2=P- Turn a newer page (deletion)

 

 

 

n1n2=PU Turn an older page (deletion)

 

 

 

n1n2=PU Move to upper layer (addition)

 

 

 

 

 

Setup

MSU:n

MSU (deletion)

n=0

End setup

 

 

MSU:n (addition)

n=1

Begin setup

Image 55
Contents Model No. WJ-HD100 ENGLISHFRANÇAIS Digital Disk Recorder Operating InstructionsENGLISH VERSION ENGLISH CONTENTSVarious alarm modes FEATURESPREFACE Easy access to the desired recordPRECAUTIONS 5!6!7 !8 Front Viewq w e t y u o!0!1!2!3!4@2 @5 Rear View@1@3@4@6 @7 @8@9 #6#7#8Power Cord #4Alarm Terminal#6Power Switch POWER ON OFF #7Signal Ground SIGNAL GNDPlaces to avoid INSTALLATIONCaution Notes Regarding Installation Mounting in the RackBasic Connection CONNECTIONConnections with PS Data Equipment Series Connection ALARM Alarm Terminal ConnectionRS-232CConnection PS Data ConnectionUnit Address & Initialize Mode Switch SettingAlarm Output Polarity TerminationTurning Off the Power SETUP PROCEDURESPrior to Setup Turning On the PowerButtons and Dials Used for the Setup Displaying the SETUP MENUCLOCK→ SF- 12H Setup Menu SequenceCLOCK→ SKIP&PLAYNOW FORMATTING HDD Initializing All Contents & Setup DataInitializing Setup Data InitializingCLOCK→ WJ-HD100SETUP MENUClock Setup 001 CLOCK Time & Date Type 002 TIME&DATE TYPEStatus Position 006 STATUS POSI Time & Date Display 003 T&D DISPLAYTime & Date Position 004 T&D POSITION Status Display 005 STATUS DISPR-LOWER SYSTEM SETUPHDD FULL Selection 007 HDD FULL Quick Play Mode Selection 101 FWD/REW MODESetting Buzzer ON/OFF 105 KEYLOCK BUZ Password Setup 102 PASSWORD LOCKAuto Erasing 109 AUTO ERASING Reset Pulse Polarity 106 RESET PULSETime Adjusting 107 TIME ADJUSTING Set Time 108 SET TIMERecording Quality 203 REC QUALITY REC SETUPRecording Mode 201 REC MODE Recording Field Rate 202 REC RATENotes on SERIES connection Disk End Mode Setup 204 DISK ENDSTOP CONTINUE ALM CONTINUE SERIESSTOP Disk End Buzzer Setup 205 DISK END BUZZERJog Click Terminal Definition 206 JOG/EXT REC External Recording Mode 207 EXT REC MODEAlarm Buzzer 305 ALARM BUZZER ALARM SETUPAlarm Recording Mode 301 REC MODE Alarm Recording Duration 304 DURATIONMotion Detector Setup 306 VMD SETUP Making Reservations INTERNAL TIMER RECBaud Rate 503 BAUD RATE COMMUNICATION SETUPProtocol 501 PROTOCOL Unit Address 502 UNIT ADDRESSWait Time 507 WAIT TIME SYSTEM INFORMATIONParity Check 505 PARITY CHECK Stop Bit 506 STOP BITWhen a button is pressed in KEY LOCK mode OPERATING PROCEDURESSequence of LCD Displays in operation Alarm RecordingRecording Internal Timer RecordingPower-onRecording Alarm RecordingStep Playback PlaybackNormal Playback Skip PlaybackPlayback Oldest/Latest Record Alarm Record SearchTime & Date Search JUN 9.00 00 Alarm History SearchJUN Alarm OperationSuspending Alarm Input Alarm History SearchCapacity in MB Resetting AlarmCopy to CompactFlash Card ManufacturerHD100 000001 000001.jpg 000002.jpg 000003.jpg Folders and FilesBlue.jpg Index.htm Play.htm Enabling Button Lock Password VerificationPASSWORD Lock/Unlock ButtonsWhat to do TROUBLESHOOTINGPhenomenon CauseGeneral SPECIFICATIONSAlarm Function Standard AccessoriesAPPENDIX Remote Control From System ControllerLoop Connection Recording SetupOperating Procedures SERIES RECORDINGOperating Procedures Series Connection RecordingPlayback Setup1Reception Command 1. Transmission Command2.Response Command Communication ProtocolBasic Operation Command TableAlarm Control Setup ControlData Log Control Miscellaneous ControlMedia Control Inquiry V8QA5548EN Panasonic Canada IncPanasonic Sales Company N0800-4120Reservation for Consecutive Days DEFAULT→ADDENDUM Reservation Past MidnightPlay Mode Display Using a graphics applicationUsing the Viewer.htm Thumbnail Mode DisplayRéservation pendant des jours consécutifs SUPPLÉMENTVERSION FRANÇAISE Réservation après minuitRemarques Utilisation de Viewer.htmAffichage de mode vignettes Affichage de mode de lectureENGLISH VERSION ADDENDUM32 Status Out Terminal on page WJ-HD100SETUP MENU on page 16, 17 andCLOCK→ Stop VMD descriptionReservation Past Midnight Reservation for Consecutive DaysAdditions to page 40, Copy to CompactFlash Card Time and date specific copyThumbnail Mode Display Play Mode Display23:00:00 Notes on alarm operation during copyingSTART JAN01.01V8RA1274CN Panasonic Canada IncPanasonic Sales Company NM0201-2012