= RM (Rec Mode)

Function: Record ready mode

Syntax: stxRM: **** , * , * , * , * , * , * ; a b c d e f g

aPhrase number

bRDAC-Grade

0Announce

1Long 2

2Long 1

3Standard

4High

5S-High

cRDAC-Mode

0Linear

1Mode1

2Mode2

3Mode3

4H-Linear

dRecording type

0Mono

1Stereo

eTrigger recording

0Off

1Low

2Mid

3High

fRecording Source

0LINE - IN

1MIDI - IN

2LINE + MIC - IN

3DIGITAL - IN

gTime base

0192

1240

Example) RM:A1,3,2,1,0,1,1;

This sets as follows; phrase “A0001”, RDAC-Grade “STANDARD”, RDAC-Mode “MODE2”,

Recording type “STEREO”, Trigger recording “OFF”, recording source”MIDI-IN”, and Time base “240”.

Note: MIDI recording refers to the recording of MIDI messages .

If recording source is “MIDI-IN”, it will enter Record ready mode for a MIDI phrase.

Caution:It is not possible to specify a phrase number which has already been recorded.

If you wish to re-record a phrase that is already recorded, use the PD command to delete the phrase, and then transmit the RM command.

AR-3000 RS-232C Reference -10

Image 15
Contents AR-3000 RS-232C Reference version RS-232C ReferenceDetails of each Command ContentsSetup Overview of CommandsSetting Commands ACK Appendix Handshaking If You Have Been Using the AR-2000Connector and Cable About the RS-232C InterfaceConnections with the Computer Setup ProcedureComputer Settings AR-3000 SettingsBaud Rate Settings Command StructureCommunication Protocol Stx + DM command About Output Parameters Command FormatPrecautions About Input ParametersDetails of each Command Phrases other than audio phrases cannot be specified Control Commands = PAPhrAse = PE PausESyntax stxRL * , **H**M**S**F stxRL * , **H**M**S If Dual Mono Mode is on= PL PLay = RL Relative time pLay= RE REc start Recording CommandsStxAE Example stxAE2001,3,1,8,59,0,0,1,0= RM Rec Mode Syntax stxRM **** , * , * , * , * , * , * a b c d e f gExample RMA1,3,2,1,0,1,1 = CP Card coPy Editing Commands= DM Delete Mode = CD Card Delete Function Delete Card Syntax stxDM= LS phrase Lock Switch LW phrase Lock sWitch for AR-3000= FM ForMat = PI Phrase sIlencer = SP Setting coPy Function System copy Syntax stxDM= PC Phrase Copy Function Copy phrase Syntax stxDM = PD Phrase DeleteStxTS StxPV ****,**H**M**S**F*SStxPM TS Time Stretch for AR-3000Syntax3 Mono1 , Mono2 to Stereo stxDM StxRT StxDM StxRTSyntax stxPU **** , * , **** , **S* , .... , **** , **S Setting CommandsPattern Phrase Settings Example stxCV0,ABCDEFGHSong Phrase number Phrase number to be played back Example SUA001,ABCDEFGHIJK,100,10S5,1,5M0S,1,5M10S,120,0 Phrase SettingsSyntax stxPP **** , **H**M**S**F*S, **H**M**S**F*S PO Phrase control Out set up for AR-3000PP phrase Playback Point set up for AR-3000 Syntax stxPO **** , *,**M**SMPphrase Midi temPo set up for AR-3000 Syntax stxMPSyntax stxTT Midi Settings = MS Midi Set up Function Midi settingsSyntax stxMS Syntax stxNM MM MMc set up for AR-3000MT MTc set up for AR-3000Function MTC settings Syntax stxMT = NM Note Map= DC Display Contrast = BR Baud RateSyntax stxDL DL Direct pLay for AR-3000 Function Direct Playback settingStxDP Example DP0,A1,,A3,A4,,A16SM SysteM for AR-2000Function System settings Syntax stxSM AR-3000 RS-232C Reference StxBO Syntax stxEQGQ sonG phrase reQuest for AR-3000 Request Commands2Q pattern phrase reQuest for AR-2000 3Q pattern phrase reQuest for AR-3000= AQ All reQuest = CQ Card reQuest= DQ Direct play reQuest Syntax stxNQ * a = LQ dispLay contrast reQuest= MQ Memory reQuest = NQ Note map reQuestSyntax stxYQ YQ sYstem reQuest for AR-3000= UQ coUnt play reQuest Syntax stxUQ= VR VeRsion = CS Card Set Reply Commands= ER ERror = Xon 11H/Xoff 13HCard ID Created automatically Reserved SU phrase Set Up for AR-2000 Function Phrase setting output S**F*S, **H**M**S**F*S,*,*, **H**M**S**F**S, **H**M**S**F**S Endless Syntax stxME Master Slave Sync Source Internal Syntax stxCR = CE Count play sEt upSyntax stxAC = CR Card Remain= DP Direct Play SY SYstem for AR-3000 Function System setting output = TI Time stamp Info Syntax stxTISyntax stxVR AR-3000 RS-232C Reference = AE Auto inc rEc start Syntax stxAE S**** aSyntax stxER * a = Xon 11H / Xoff 13H # Setting Commands # Card Settings AR-3000 Commands List 1 AR-2000 Compatible Commands List# Control Commands # Playback Commands Editing CommandsReply Commands # Reply Commands# Commands sent from the AR-3000 to the external device # Setting Output Commands# System Settings # Editing Commands # Card Editing# Setting Commands # Phrase Settings # Midi SettingsCharacters That Can Be Used in Phrase Names and Card Names # Setting Output Commands # Phrase SettingsPlaying Back a Phrase Sample AlgorithmsRecording Nomal Recording Recording Time-Stamped Recording What is the Phrase Output Counter? Deleting a Phrase