Lincoln Electric SVM151-A service manual Safety, California Proposition 65 Warnings

Page 2

Return to Master TOC

TOC

i

i

 

SAFETY

WARNING

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents

 

The engine exhaust from this product contains

are known to the State of California to cause can-

 

chemicals known to the State of California to cause

cer, birth defects, and other reproductive harm.

 

cancer, birth defects, or other reproductive harm.

 

 

 

The Above For Diesel Engines

 

The Above For Gasoline Engines

ARC WELDING can be hazardous. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

Return to Master

Return to Master TOC

Return to Master TOC

FOR ENGINE powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.

____________________________________________________

1.b.Operate engines in open, well-ventilated areas or vent the engine exhaust fumes

outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame weld- ing arc or when the engine is running. Stop the engine and allow it to cool before refuel- ing to prevent spilled fuel from vaporizing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes

have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle con- trol rods while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.

1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.

ELECTRIC AND MAGNETIC FIELDS may be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.

2.c. Exposure to EMF fields in welding may have other health effects which are now not known.

2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.

2.d.5. Do not work next to welding power source.

Mar ‘95

Image 2
Contents Multi-Weld TM 350 Arc Converter Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation Section Installation Technical Specifications MULTI-WELD 350 K1735-1Safety Precautions QUICK-CONNECT PIG-TAILSWork Connection Case GroundingFixed Parallel Operation Power Source Setup Converters Cable Size On Cable AWG mm2Table of Contents Operation Section Operating Instructions Safety InstructionsOperation Portable Product DescriptionVersatile Recommended Equipment and Processes MULTI-SYSTEM Power SourcePIG-TAIL Leads and Connectors Distribution BOXRemote Output Control Options CV Mode Wire WeldingCC Mode Stick Welding and Gouging Input Power/ Mode Switch has three positions Front Panel ControlsRecessed Panel Controls Transporting and Storage of the MULTI-WELD For CC STICK/GOUGE Mode onlyParalleled Converters Cable HandlingProtection Features MULTI-WELD Table of Contents Accessories Section Semiautomatic Welding Accessories AccessoriesOPTIONS/ACCESSORIES Connection of Lincoln Electric Wire FeedersTo Work MULTI-WELD Section D-1 Table of ContentsMaintenance Section See additional warning information throughout this manual MaintenanceMaintenance Service Figure D.2 Major Component LocationsMULTI-WELD Table of Contents Theory of Operation Section Theory of Operation General DescriptionPower Modules and FEED- Back Figure E.3 Power Modules and FeedbackAnalog Control Power Supply Board and Weld Control Board Mode Selector and Output Controls Figure E.5 Mode Selector and Output ControlsOVER-VOLTAGE Protection Insulated Gate Bipolar Transistor Igbt Operation Pulse Width Modulation 8E-8Chopper Technology Fundamentals 70-80VDCMULTI-WELD Table of Contents Troubleshooting & Repair Section Troubleshooting & Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures PC Board can be damaged by static electricityPerform the DC Buss Supply Troubleshooting GuidePower Supply Board Test Board TestCoil Resistance and Supply SpecificationsPerform the Input Contactor Voltage TestInput Voltage and Resistance TestFunction Problems See the Digital Meter Calibra Analog Control Power Supply Board TestTion and Adjustment Test Perform the DC Buss Supply Welding Problems Troubleshooting & Repair Troubleshooting & Repair Materials Needed Case Cover Assembly Removal Replacement ProcedureTest Description Removal Procedure Replacement ProcedurePower Module Capacitor Discharge Procedure Procedure Figure F.2 Power Module Capacitor Terminal DischargeInput Contactor Coil Resistance and Supply Voltage Test Input Contactor Coil Resistance Supply Voltage Test Coil Test ProcedurePerform the Power Module Capacitor Discharge procedure Leads #303A #330Test for Contact Continuity Supply PC Board TestAnalog Control Power Supply PC Board Test Test Procedure Figure F.4 Analog Control Power Supply PC BoardPower Supply PC Board Test DC Buss Power Supply PC Board Test DC Buss Power Supply PC Board P46 P47Table F.2 DC Buss Power Supply PC Board Voltage Table Chopper PC Board Input Voltages and Resistance Test Figure F.6 Power Module Assembly Details Chopper PC Board Input Voltages Resistance TestTest Procedure for the Left Side Power Module Power Module Capacitor Discharge ProcedureNormal Open Circuit Voltage Waveform CC Mode Input Voltage Applied 75 VDCScope Settings CV Mode Output Control AT Maximum Machine Loaded to 350 Amps AT 34 Volts CC-STICK Mode Normal Weld Voltage WaveformMachine Loaded to 350 Amps AT 34 Volts CV Mode CV Mode Output Control AT Minimum Case Front Assembly Removal and Replacement DescriptionReplace the case cover Weld Control or Peripheral PC Board Removal and Replacement Figure F.8 Case Front Assembly Details Replacement Procedure Description Digital Meter Removal Procedure Lens Bezel Spacer Seal KnobOutput Control Potentiometer Removal Procedure Refer to Figure F.9Input Contactor Removal and Replacement Figure F.10 Input Contactor Assembly Details Lead #331Replacement Procedure Input Diode Removal and Replacement Figure F.11 Input Diode Assembly Details 25-27 300-324 Refer to Figure F.11FAN Motor Assembly Removal and Replacement Figure F.12 FAN Motor Assembly Details Perform the Input Diode Replacement procedure Perform the Input Diode Removal proce- durePower Capacitor Removal and Replacement Figure F.13 Power Capacitor Mounting Details Reassembly Chopper PC Board and Diode Module Removal and Replacement Chopper PC Board Removal and Replacement RemovalReplacement Refer to Figure F.14Diode Module Removal and Replacement Figure F.15 Diode Module Mounting DetailsRefer to Figure F.15 Figure F.16 Diode Module Tightening Sequence Open Circuit Voltages Retest After RepairIdle Amps Load TestElectrical Diagrams Table of Contents Electrical Diagrams SectionMULTI-WELD 350 Wiring Diagram Wiring Diagram MULTI-WELDSchematic Control PC Board #1 Schematic Control PC Board #2 Schematic Control PC Board #3 Schematic Control PC Board #4 Schematic Control PC Board #5 PC Board ASSEMBLY-CONTROL RESISTOR,SMD,1W,243OHMS,1%Schematic Peripheral Printed Circuit Board PC Board ASSEMBLY-PERIPHERAL PC Board Reference Description DesignatorsSchematic Power Printed Circuit Board PC Board ASSEMBLY-POWER Return to Section Return to Section TOC To Section TOCSchematic Analog Printed Circuit Board PC Board ASSEMBLY-ANALOG Schematic BY-PASS Printed Circuit Board PC Board Assembly BY-PASS Schematic Chopper Printed Circuit Board 19303 MPC Board Assembly Chopper SVM Error Reporting Form