TROUBLESHOOTING & REPAIR |
| |||||
TROUBLESHOOTING GUIDE |
|
|
|
| Observe Safety Guidelines | |
|
|
| detailed in the beginning of this manual. | |||
|
|
|
| |||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED | ||||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION | ||||
|
|
|
|
| ||
| OUTPUT PROBLEMS |
|
|
| ||
The meters light, but the input con- | 1. Make sure the input voltage | 1. | Check leads 330 and 303A for | |||
tactor does not activate when the | applied to the |
| loose or faulty connections. | |||
ON/OFF Mode Selector switch is | not greater than 113VDC. |
| See the Wiring Diagram. | |||
turned on. The |
|
|
| 2. | Perform the Input Contactor | |
does not have output. |
|
|
| |||
|
|
|
| Coil Resistance and Supply | ||
|
|
|
|
| ||
|
|
|
|
| Voltage Test. | |
|
|
|
| 3. | The Peripheral Board may be | |
|
|
|
|
| faulty. | |
|
|
|
| 4. | The Weld Control Board may be | |
|
|
|
|
| faulty. | |
|
|
|
|
| ||
The Thermal Light is on. The Multi- | 1. The output rating of the | 1. | The Thermostat, located on the | |||
Weld 350 does not have output. | machine | may be | exceeded. |
| input diode heat sink, may be | |
The fan operates normally. | See | the | Technical |
| faulty. | |
| Specifications. |
| 2. | Check leads 306, 307, 206, 207 | ||
|
|
|
| |||
| 2. Wait until the machine cools and |
| and plugs J22 and J11 for loose | |||
| the Thermal Light goes out. The |
| or faulty connections. See the | |||
| machineís output | should be |
| Wiring Diagram. | ||
| restored. |
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call