Lincoln Electric SVM151-A service manual Welding Sparks can cause fire or explosion, Iii

Page 4

iii

iii

SAFETY

Return to Master TOC

Return to Master TOC

Return to Master TOC

WELDING SPARKS can cause fire or explosion.

6.a. Remove fire hazards from the welding area. If this is not possible, cover them to prevent the welding sparks from starting a fire. Remember that welding sparks and hot

materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.

6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1) and the operating information for the equipment being used.

6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.

6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended Safe Practices for the Preparation for Welding and Cutting of Containers and Piping That Have Held Hazardous Substances”, AWS F4.1 from the American Welding Society (see address above).

6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.

6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places. Always wear safety glasses with side shields when in a welding area.

6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.

6.h. Also see item 1.c.

CYLINDER may explode if damaged.

7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and

pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.

7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.

7.c. Cylinders should be located:

Away from areas where they may be struck or subjected to physical damage.

A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.

7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.

7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.

7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.

7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l, “Precautions for Safe Handling of Compressed Gases in Cylinders,” available from the Compressed Gas Association 1235 Jefferson Davis Highway, Arlington, VA 22202.

FOR ELECTRICALLY powered equipment.

8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.

8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.

8.c. Ground the equipment in accordance with the U.S. National Electrical Code and the manufacturer’s recommendations.

Return to Master TOC

Mar ‘95

Image 4
Contents Multi-Weld TM 350 Arc Converter Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation Section Installation Technical Specifications MULTI-WELD 350 K1735-1Safety Precautions QUICK-CONNECT PIG-TAILSWork Connection Case GroundingFixed Parallel Operation Power Source Setup Converters Cable Size On Cable AWG mm2Table of Contents Operation Section Operation Safety InstructionsOperating Instructions Versatile Product DescriptionPortable MULTI-SYSTEM Power Source PIG-TAIL Leads and ConnectorsRecommended Equipment and Processes Distribution BOXCC Mode Stick Welding and Gouging CV Mode Wire WeldingRemote Output Control Options Input Power/ Mode Switch has three positions Front Panel ControlsRecessed Panel Controls For CC STICK/GOUGE Mode only Paralleled ConvertersTransporting and Storage of the MULTI-WELD Cable HandlingProtection Features MULTI-WELD Table of Contents Accessories Section Accessories OPTIONS/ACCESSORIESSemiautomatic Welding Accessories Connection of Lincoln Electric Wire FeedersTo Work MULTI-WELD Maintenance Section Table of ContentsSection D-1 Maintenance MaintenanceSee additional warning information throughout this manual Service Figure D.2 Major Component LocationsMULTI-WELD Table of Contents Theory of Operation Section Theory of Operation General DescriptionPower Modules and FEED- Back Figure E.3 Power Modules and FeedbackAnalog Control Power Supply Board and Weld Control Board Mode Selector and Output Controls Figure E.5 Mode Selector and Output ControlsOVER-VOLTAGE Protection Insulated Gate Bipolar Transistor Igbt Operation Pulse Width Modulation 8E-8Chopper Technology Fundamentals 70-80VDCMULTI-WELD Table of Contents Troubleshooting & Repair Section Troubleshooting & Repair HOW to USE Troubleshooting GuidePC Board Troubleshooting Procedures PC Board can be damaged by static electricityTroubleshooting Guide Power Supply Board TestPerform the DC Buss Supply Board TestSpecifications Perform the Input ContactorCoil Resistance and Supply Voltage TestInput Voltage and Resistance TestFunction Problems Tion and Adjustment Test Analog Control Power Supply Board TestSee the Digital Meter Calibra Perform the DC Buss Supply Welding Problems Troubleshooting & Repair Troubleshooting & Repair Test Description Case Cover Assembly Removal Replacement ProcedureMaterials Needed Removal Procedure Replacement ProcedurePower Module Capacitor Discharge Procedure Procedure Figure F.2 Power Module Capacitor Terminal DischargeInput Contactor Coil Resistance and Supply Voltage Test Coil Test Procedure Perform the Power Module Capacitor Discharge procedureInput Contactor Coil Resistance Supply Voltage Test Leads #303A #330Test for Contact Continuity Supply PC Board TestAnalog Control Power Supply PC Board Test Test Procedure Figure F.4 Analog Control Power Supply PC BoardPower Supply PC Board Test DC Buss Power Supply PC Board Test DC Buss Power Supply PC Board P46 P47Table F.2 DC Buss Power Supply PC Board Voltage Table Chopper PC Board Input Voltages and Resistance Test Figure F.6 Power Module Assembly Details Chopper PC Board Input Voltages Resistance TestTest Procedure for the Left Side Power Module Power Module Capacitor Discharge ProcedureScope Settings CC Mode Input Voltage Applied 75 VDCNormal Open Circuit Voltage Waveform CV Mode Output Control AT Maximum Machine Loaded to 350 Amps AT 34 Volts CC-STICK Mode Normal Weld Voltage WaveformMachine Loaded to 350 Amps AT 34 Volts CV Mode CV Mode Output Control AT Minimum Case Front Assembly Removal and Replacement DescriptionReplace the case cover Weld Control or Peripheral PC Board Removal and Replacement Figure F.8 Case Front Assembly Details Replacement Procedure Description Digital Meter Removal Procedure Lens Bezel Spacer Seal KnobOutput Control Potentiometer Removal Procedure Refer to Figure F.9Input Contactor Removal and Replacement Figure F.10 Input Contactor Assembly Details Lead #331Replacement Procedure Input Diode Removal and Replacement Figure F.11 Input Diode Assembly Details 25-27 300-324 Refer to Figure F.11FAN Motor Assembly Removal and Replacement Figure F.12 FAN Motor Assembly Details Perform the Input Diode Replacement procedure Perform the Input Diode Removal proce- durePower Capacitor Removal and Replacement Figure F.13 Power Capacitor Mounting Details Reassembly Chopper PC Board and Diode Module Removal and Replacement Chopper PC Board Removal and Replacement RemovalReplacement Refer to Figure F.14Diode Module Removal and Replacement Figure F.15 Diode Module Mounting DetailsRefer to Figure F.15 Figure F.16 Diode Module Tightening Sequence Retest After Repair Idle AmpsOpen Circuit Voltages Load TestElectrical Diagrams Table of Contents Electrical Diagrams SectionMULTI-WELD 350 Wiring Diagram Wiring Diagram MULTI-WELDSchematic Control PC Board #1 Schematic Control PC Board #2 Schematic Control PC Board #3 Schematic Control PC Board #4 Schematic Control PC Board #5 PC Board ASSEMBLY-CONTROL RESISTOR,SMD,1W,243OHMS,1%Schematic Peripheral Printed Circuit Board PC Board ASSEMBLY-PERIPHERAL PC Board Reference Description DesignatorsSchematic Power Printed Circuit Board PC Board ASSEMBLY-POWER Return to Section Return to Section TOC To Section TOCSchematic Analog Printed Circuit Board PC Board ASSEMBLY-ANALOG Schematic BY-PASS Printed Circuit Board PC Board Assembly BY-PASS Schematic Chopper Printed Circuit Board 19303 MPC Board Assembly Chopper SVM Error Reporting Form