TROUBLESHOOTING & REPAIR |
|
|
| ||||
TROUBLESHOOTING GUIDE |
|
|
| Observe Safety Guidelines | |||
|
| detailed in the beginning of this manual. | |||||
|
|
|
|
| |||
PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| |||
(SYMPTOMS) | MISADJUSTMENT(S) | COURSE OF ACTION |
|
| |||
|
|
|
|
|
|
|
|
|
| FUNCTION PROBLEMS |
|
|
|
|
|
The preset amps (CC mode) or | 1. | The panel Output Control is dis- | 1. | The Output Control (R1) may be | |||
volts (CV mode) are not adjustable. |
| abled when a remote control |
| faulty. | Check or replace. | Also | |
|
| device is plugged into the |
| check | associated leads | for | |
|
| remote receptacle. |
| loose or faulty connections. |
|
| |
|
|
| 2. | Check all the plug connections | |||
|
|
|
| to the Weld Control Board for | |||
|
|
|
| loose | or faulty connections. | ||
|
|
|
| See the Wiring Diagram. |
|
| |
|
|
| 3. | The Weld Control Board may be | |||
|
|
|
| faulty. Replace. |
|
| |
|
|
|
|
|
| ||
The preset range is not correct. | 1. | The panel Output Control is dis- | 1. | Make sure plug P3 is connected | |||
|
| abled when a remote control |
| securely to receptacle J3 on the | |||
|
| device is plugged into the |
| Weld Control Board. See the | |||
|
| remote receptacle. |
| Wiring Diagram. Make certain | |||
|
|
|
| all the jumper leads are in place. | |||
|
|
| 2. | Check all the plug connections | |||
|
|
|
| to the Weld Control Board for | |||
|
|
|
| loose | or faulty connections. | ||
|
|
|
| See the Wiring Diagram. |
|
| |
|
|
| 3. | The Weld Control Board may be | |||
|
|
|
| faulty. Replace. |
|
| |
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call