TROUBLESHOOTING AND REPAIR | ||
|
|
COVER AND SPINDLE MOUNT
REMOVAL AND REPLACEMENT PROCEDURE (Continued)
Figure F.14 - COVER AND SPINDLE MOUNT LOCATION
Cord Grip Nut
Spindle Mount
Cover
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
REMOVAL PROCEDURE
1.Remove input power to the
2.Open door.
3.Locate the spindle mount and cover assembly. See Figure F.14.
4.Using the 1/2” wrench remove the one bolt from the top of the cover.
5.Using the 3/8” wrench remove the five mounting screws. See Figure F.15.
6.Using the large pliers loosen and remove the cord grip nut. See Figure F.14.
7.Pull the electrode cable inward through the rear case.
8.Disconnect the gas hose from the conductor block on the Wire Drive Assembly.
9.Carefully remove the cover and spindle assembly from the case. Be careful not to damage the switches, leads or solenoid.
10.If complete removal is necessary disconnect the leads from the switches and solenoid. Be sure to label for reassembly.