Lincoln Electric SAE-300 manual Wire Feeder Options

Page 17

C-2

ACCESSORIES

C-2

 

 

 

WIRE FEEDER OPTIONS

Wire Feed Module K623-1

Provides constant voltage (CV) output with improved arc stability for Innershield welding. Excellent for MIG welding. Recommended wire feeders are the LN-7, LN-23P and LN-25.

Remote Control Kit K2464-1

(Stick & Wire)

For Classic® and Pipeliner® machines that have the wire feed module. Contains a rheostat for stick output, a potentiometer for wire output and 100 ft. (30 m) of control cable.

LN-25 PRO Wire Feeder K2613-1

Portable CC/CV unit for flux-cored and MIG welding with MAXTRAC® wire drive system. Includes Gas Solenoid & Internal Contactor. Requires Wire Feed Module.

Magnum® 350 Innershield Gun for LN-25 K126-12 For self-shielded wire with 15 ft. (4.5m) cable. For

.072”(1.9mm) (5/64” (2.0mm) wire.

Magnum® PRO 350 Ready-Pak® K2652-2-10-45 15 ft., .035-5/64 in.

Magnum® PRO MIG/flux-cored welding guns are rated 100% duty cycle. The guns are designed for high amperage, high duty cycle applications in extreme environments where heat-resistance and fast serviceability are key.

Drive Roll and Guide Tube Kit (for LN-25 PRO) KP1697-068 for .068-.072 in. (1.8 mm) KP1697-5/64 for 5/64 in. (2.0 mm)

For cored or solid steel wire.

Magnum® 300 MIG Gun and Cable Package LN-25 PRO K1802-1 (includes K466-1 Connector Kit)

For .035-.045 in. (0.9-1.2 mm) gas-shielded wire with 15 ft. (4.5 m) cable.

Drive Roll and Guide Tube Kit (for LN-25 PRO) KP1696-1

For .035 in. and .045 in. (0.9 mm and 1.1 mm) solid steel wire.

Magnum Spool Gun K487-25

Hand held semiautomatic wire feeder requires SG Control Module. 25 ft. length.

SG Control Module K488 (For Magnum Spool Gun)

The interface between the power source and the spool gun. Provides control of wire speed and gas flow.

Input Cable K691-10 ( For SG Control Module)

For Lincoln engine drives with 14-pin MS-type con- nection, separate 115V NEMA receptacle and output stud connections. 10 ft. length.

SAE-300®

Image 17
Contents SAE-300 California Proposition 65 Warnings SafetyFuMES and Gases can be dangerous Electric ShOCK can killARC Rays can burn Iii Welding and CuTTING Sparks can Cause fire or explosionCylinder may explode if damaged Sûreté Pour Soudage a L’Arc PRÉCAuTIONS DE SûretéOn-Line Product Registration Please Examine Carton and Equipment For Damage ImmediatelyTAbLE of Contents TEChNICAL Specifications SAE-300 InstallationDescription Volts @ Rated Amps CycleReceptacle Design FEATuRESGeneral Description Trailer see Optional FEATuRES PRE-OPERATION InstallationLocation / Ventilation MAChINE GROuNDINGCooling System PRE-OPERATION ServiceOIL BATTERY ChARGING 5INSTALLATIONA-5To prevent ExPLOSION when To prevent Electrical Damage whenENGINE OPERATION OperationStarting ThE SAE-300 404D-22 Diesel Engine Cold WEAThER StartingStick / TIG Welding Welder OperationEngine bREAK-IN Idler Operation MIG WeldingOptional FEATuRES Field Installed AccessoriesWire Feeder Options Safety PRECAuTIONS MaintenanceGeneral INSTRuCTIONS Cooling SystemNameplates Idler MaintenancePuRGING AIR from FuEL System Perkins 404D-22 Engine Vent Screw Priming LeverMaintenance PROCEDuRE Gfci Testing and ResettingHOW to uSE TROubLEShOOTING GuIDE TROubLEShOOTINGSymptoms PRObLEMSPOSSIbLE CAuSE RecommendedYour local Lincoln Authorized POSSIbLE Areas of MISADJuSTMENTSSOpen Closed Electronic Idler TROubLEShOOTING GuIDEDefective -- Will Not Close Auxiliary Power Load is Turned onContact your local Lincoln Authorized Field Service FacilityWater passage. Flush the system Ing on Faulty light wiring Diagrams S10766-14 Atenção Atenção