Lincoln Electric LN-9 GMA, LN-9F GMA manual Guide Tube Detail

Page 33

b-10

b-10

OPERATION

FIGURE b.5 – INSTALLING DRIVE ROLLS ON A 2-ROLL FEEDER

CLAMPING

COLLAR

SPACER

DRIVE(IF REQ'D)

ROLL

HALVES

 

OUTPUT

KEY

SHAFT

 

GUIDE TUBE DETAIL

LARGE

 

RADIUS

OUTGOING

DRIVE

GUIDE TUBE

ROLL

OUTGOING

 

GUIDE TUBE

 

INSERT

 

INCOMING

GUIDE

IDLETUBE

ROLL

SMALL

RADIUS

LN-9 GMA and LN-9F GMA Wire Feeder

Image 33
Contents Safety Depends on You LN-9 GMA and LN-9F GMA Wire FeederSafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté Thank You TAbLE of Contents TAbLE OF CONTENTS cont’d Section E ViiiSection F P127, P125, P107 & P289 SeriesTechnical Specifications LN-9 GMA and LN-9F GMA Wire FeederWidth Height Attaching the Wire Reel Stand Installing the LN-9 GMA Roll and 4-ROLL ModelsMounting the Wire Feed Unit Mounting the UnitPower Input CAbLE ASSEMbLY Electrical Connections LN-9 GMA and LN-9F GMARouting the Electrode Figure A.3 LN-9F GMA Control bOX Figure A.2 Strain Relief ClampInstallation Can kill Figure A.5 Connection of LN-9 GMA to DC-600 Power Sources Figure A.6 Connection of LN-9 GMA to DC-1000 Power Sources 75 76 77 Installation Figure A.9 Connection of LN-9 GMA to V300 Power Sources Direct Work Lead Connection Machine GroundingFor GMA GUN CAbLES Connecting the GUN CAbLE to the Wire FeederCylinder may explode if damaged Hooking UP GMA Shielding GASOperating Instructions Safety PrecautionsRecommended Processes and Equipment General DescriptionK424 LN-9 GMA 2-ROLL and K568-1 LN-9 GMA 4-ROLL K436 LN-9F GMA 2-ROLL and K583-1 LN-9F GMA 4-ROLLDC Constant Voltage Power Sources Controls and Settings Operation Operation Circuit Protection and Automatic Shutdown Power Supply FuseAvoiding Grounding Lead Protector GLP Shutdown Circuit bREAKERAutomatic Shutdown Changing Drive Rolls for 2-ROLL Wire Feeders Drive Roll InstallationGuide Tube Detail Changing Drive Rolls for 4-ROLL Wire Feeders Large Figure b.7a Threaded Locking Collar Wire LoadingFeeding Electrode and bRAKE Adjustment Loading a 50-60 Lb .7-27.2 KG. Coil Using K1504-1 Coil ReelLoading a 50 or 60 Lb. Coil ADJUSTAbLE Wire Reel bRAKEInnershield Coils K378 Reel Mounting Stand Loading and Feeding 13-14 LbIdle Roll Pressure Setting Roll Wire FeedersFor TWO-ROLL Feeders Pressure Adjustment Knob Adjust the LN-9 GMA Controls Adjust the Power SourcePulse Power 500, DC650 PRO CV-400, CV-500-I DC-250, DC-400, or DC-600RUN-IN Feature Starting CharacteristicsVoltage Control Response Select AccelerationProcedure AT END of Coil Security of Weld Procedure SettingsMaking a Weld Power Input CAbLE ASSEMbLIES K196, K595, K596 Optional Equipment and AccessoriesWire Reel Stands and Mountings Auxiliary Equipment ContactsWire Reel Door KIT Attaching the Wire Reel StandsSpindle for READI-REELS and 2 I.D. Spools K162-H READI-REEL AdaptersUniversal Wire Reel Stand K1524-1 BURNbACK Timer KIT K419 Wire Feeder AccessoriesDual Process KIT K317 For Wire Feeders GMA Timer KIT K418Dual Procedure KIT K319 Pulse Power Filter Conversion KIT K442-1Undercarriage K163 Swivel Platform K178-1Continuous Flux Feed Tank K320 K320 Flux Tank LoadingK58 Magnetic Separator Kit Roll Solid Steel Electrode TAbLE C.2 Drive Roll and Guide TUbE KitsCored Electrode Aluminum ElectrodePeriodic Maintenance Routine MaintenanceCoils with 1 Spindle AdapterFigure D.1 Speed Sensor Module Location Proper Speed Sensor Module MountingFigure D.2 Switch Requirements Figure D.2 LN-9 GMA ConnectorsTROUbLESHOOTING Wire Feeding PRObLEMS TROUbLESHOOTING GuideGun trigger will not feed wire. Digital meter is not lit Grounding Lead Protector Shutdown in the Operation section TROUbLESHOOTING Welding PRObLEMS Starting Characteristics Wire LN-9 GMA WIRINGLN-9F GMA LN-9 GMA Dimension Print LN-9F GMA Dimension Print 1 Wire Drive Unit Control bOX LN-9F Dimension Print 2Page Precaucion Keep your head out of fumes LN-9 GMA Wire Feeder