Lincoln Electric LN-9F GMA, LN-9 GMA manual ADJUSTAbLE Wire Reel bRAKE, Loading a 50 or 60 Lb. Coil

Page 38

b-15

b-15

OPERATION

LOADING 50 AND 60 Lb. COILS ON 1” SPINDLE (K299 or K303 Wire Reel Stand)

ADJUSTAbLE WIRE REEL bRAKE

The mount for standard 50 and 60 pound electrode coils includes a two position brake assembly. Generally the brake should be a the inner position (nearest to the wire reel shaft) for wire feed speeds below 400 in/min. It should be at the outer position for the faster wire speeds often used when feeding small diameter electrode.

To adjust the brake position, remove the wire reel. Pull the cotter pin that holds the brake shoe to the arm, move the shoe and replace the cotter pin. Do not bend the cotter pin - it is held in place by a friction fit.

LOADING A 50 OR 60 Lb. COIL

1.To remove the wire reel from its shaft, grasp the spring loaded knob and pull it out. This straightens the knob so that it seats into the shaft when released. Remove the reel.

2.Lay the reel flat on the floor, loosen the spinner nut and remove the cover plate.

3.Before cutting the tie wires, place the coil of elec- trode on the reel so that it unwinds as the reel rotates clockwise.

a)Be sure the coil is placed so that the spring loaded arms will not interfere with the later removal of the coil tie wires. See Figure B.8.

FIGURE b.8 – LOADING A 50 OR 60 Lb. COIL

SPINNER

NUT

COVER

PLATE

SLOTS

CARDBOARD

COIL

LINER

COIL

 

TIE WIRE

REEL

SPRING

 

LOADED

 

ARM

b)When loading 0.030, 0.035 and 0.045" electrode, be certain the coil is placed on the reel so that the spring loaded arms are at the center of the slots in the cardboard coil liner. This provides the positive compression of the coil sides needed for trouble free wire feeding. See Figure B.8.

c)Put the cover plate on the reel so that the four arms of the cover straddle and are in line with the spring loaded arm of the reel.

4.Tighten the cover as much as possible by hand. DO NOT hammer on the spinner nut arms.

5.Cut and remove only the tie wire holding the free end of the coil. Insert the free end into one of the holes in the cover and secure it by bending it back. Cut and remove the remaining tie wires.

CAUTION

Always be sure the free end of the coil is securely held while the tie wires are being cut and until the wire is feeding through the drive rolls. Failure to do this will result in "backlashing" of the coil, which may tangle the wire. A tangled coil will not feed; therefore it must either be untangled or discarded.

6.Replace the reel on the wire feeder. Grasp the shaft knob, pull it out and swing it across the reel hub, locking the reel in place.

7.The mount for standard 50 and 60 pound electrode coils includes a two-position brake assembly. Generally the brake should be at the inner position (nearest to the wire reel shaft) for wire feed speeds below 400 in/min. It should be at the outer position for the faster wire speeds often used when feeding small diameter electrode.

To adjust the brake position, remove the wire reel. Pull the cotter pin that holds the brake shoe to the arm, move the shoe and replace the cotter pin. Do not bend the cotter pin - it is held in place by a fric- tion fit.

LN-9 GMA and LN-9F GMA Wire Feeder

Image 38
Contents LN-9 GMA and LN-9F GMA Wire Feeder Safety Depends on YouSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Thank You TAbLE of Contents TAbLE OF CONTENTS cont’d Section F ViiiSection E P127, P125, P107 & P289 SeriesWidth Height Technical SpecificationsLN-9 GMA and LN-9F GMA Wire Feeder Mounting the Wire Feed Unit Installing the LN-9 GMA Roll and 4-ROLL ModelsAttaching the Wire Reel Stand Mounting the UnitRouting the Electrode Power Input CAbLE ASSEMbLYElectrical Connections LN-9 GMA and LN-9F GMA Figure A.2 Strain Relief Clamp Figure A.3 LN-9F GMA Control bOXInstallation Can kill Figure A.5 Connection of LN-9 GMA to DC-600 Power Sources Figure A.6 Connection of LN-9 GMA to DC-1000 Power Sources 75 76 77 Installation Figure A.9 Connection of LN-9 GMA to V300 Power Sources Machine Grounding Direct Work Lead ConnectionConnecting the GUN CAbLE to the Wire Feeder For GMA GUN CAbLESHooking UP GMA Shielding GAS Cylinder may explode if damagedSafety Precautions Operating InstructionsK424 LN-9 GMA 2-ROLL and K568-1 LN-9 GMA 4-ROLL General DescriptionRecommended Processes and Equipment K436 LN-9F GMA 2-ROLL and K583-1 LN-9F GMA 4-ROLLDC Constant Voltage Power Sources Controls and Settings Operation Operation Avoiding Grounding Lead Protector GLP Shutdown Power Supply FuseCircuit Protection and Automatic Shutdown Circuit bREAKERAutomatic Shutdown Drive Roll Installation Changing Drive Rolls for 2-ROLL Wire FeedersGuide Tube Detail Changing Drive Rolls for 4-ROLL Wire Feeders Large Wire Loading Figure b.7a Threaded Locking CollarLoading a 50-60 Lb .7-27.2 KG. Coil Using K1504-1 Coil Reel Feeding Electrode and bRAKE AdjustmentADJUSTAbLE Wire Reel bRAKE Loading a 50 or 60 Lb. CoilLoading and Feeding 13-14 Lb Innershield Coils K378 Reel Mounting StandFor TWO-ROLL Feeders Pressure Adjustment Knob Idle Roll Pressure SettingRoll Wire Feeders Pulse Power 500, DC650 PRO CV-400, CV-500-I Adjust the Power SourceAdjust the LN-9 GMA Controls DC-250, DC-400, or DC-600Voltage Control Response Starting CharacteristicsRUN-IN Feature Select AccelerationMaking a Weld Procedure AT END of CoilSecurity of Weld Procedure Settings Wire Reel Stands and Mountings Optional Equipment and AccessoriesPower Input CAbLE ASSEMbLIES K196, K595, K596 Auxiliary Equipment ContactsSpindle for READI-REELS and 2 I.D. Spools K162-H Attaching the Wire Reel StandsWire Reel Door KIT READI-REEL AdaptersUniversal Wire Reel Stand K1524-1 Wire Feeder Accessories BURNbACK Timer KIT K419Dual Procedure KIT K319 GMA Timer KIT K418Dual Process KIT K317 For Wire Feeders Pulse Power Filter Conversion KIT K442-1Continuous Flux Feed Tank K320 Swivel Platform K178-1Undercarriage K163 K320 Flux Tank LoadingK58 Magnetic Separator Cored Electrode TAbLE C.2 Drive Roll and Guide TUbE KitsKit Roll Solid Steel Electrode Aluminum ElectrodeCoils with 1 Spindle Routine MaintenancePeriodic Maintenance AdapterProper Speed Sensor Module Mounting Figure D.1 Speed Sensor Module LocationFigure D.2 LN-9 GMA Connectors Figure D.2 Switch RequirementsTROUbLESHOOTING TROUbLESHOOTING Guide Wire Feeding PRObLEMSGun trigger will not feed wire. Digital meter is not lit Grounding Lead Protector Shutdown in the Operation section TROUbLESHOOTING Welding PRObLEMS Starting Characteristics LN-9 GMA WIRING WireLN-9F GMA LN-9 GMA Dimension Print LN-9F GMA Dimension Print 1 Wire Drive Unit LN-9F Dimension Print 2 Control bOXPage Precaucion LN-9 GMA Wire Feeder Keep your head out of fumes