Lincoln Electric LN-9F GMA manual Figure D.2 LN-9 GMA Connectors, Figure D.2 Switch Requirements

Page 54

D-3

D-3

MAINTENANCE

GUN CAbLE CONNECTOR REQUIRE-

MENTS TO PERMIT PROPER CONNEC- TION TO LINCOLN LN-9 GMA AND LN-9F GMA WIRE FEEDER

The following Figures D.2 and D.3 should serve as a guide to determine if a particular gun or switch can be connected to the LN-9 GMA and LN-9F GMA.

FIGURE D.2 – LN-9 GMA CONNECTORS

.749 (19.0)

.747 (18.9)

.62 (15.7) DIA.

.03 x 45° (.76 x 45°)

max1.25

(31.7)

.062R (1.5R)

Style "A"

 

 

 

 

"A" DIA HOLE

 

 

.295 (7.49)

 

 

.290 (7.36)

Connector must be

 

.252 (6.40)

insulated in this area

 

1.00

.260 (6.60)

 

 

 

 

(25.4)

 

2.00

1.25

 

(51.0)

(31.7)

 

LN-9 CONNECTOR FOR 1/16-5/64” (1.6-2.0 MM) WIRE)

.180 (4.5)

.160 (4.0)

.03 x 45° (.76 x 45°)

Style "B"

"A" DIA HOLE

.495 (12.5) DIA. MAX.

LN-9 CAbLE CONNECTOR FOR .023-.052” (0.6-1.3 mm)

WIRE (FOR ALL OTHER DIMENSIONS, SEE DIAGRAM

AbOVE).

 

 

“A” Diameter Hole

 

 

to be Concentric to

Wire Size

.749/.747 (19.0/18.9)

in. (mm)

Diameter Within .008 (.20) F.I.M.

0.68-5/64

(1.7-2.0)

.125 [1/8” (3.2 mm) Drill]

 

 

1/16-0.062 (1.6)

.078 [5/64” (2.0 mm) Drill]

.045 & .052

(1.1 & 1.3)

.062 [1/16” (1.6 mm) Drill]

.023-.035

(0.6-0.9)

.055 [(1.4 mm) #54 Drill]

 

 

 

All dimensions in inches and (millimeters).

FIGURE D.2 – SWITCH REQUIREMENTS

1/2 Amp AC 24 Volts — Inductive

1/2 Amp DC 24 Volts — Inductive

To Gun Switch

Connect Leads to

Pins "A" & "C"

S12024-1 (L.E. Part No.)

Amphenol AN3057-10 (or equiv.)

S12020-6 (L.E. Part No.)

Amphenol MS-3106A-18-11P (or equiv.)

NOTE: Connector part with .7459/.747 (19.0/18.9) diameter should be made from brass if it is to be part of the welding current carrying circuit.

LN-9 GMA and LN-9F GMA Wire Feeder

Image 54
Contents LN-9 GMA and LN-9F GMA Wire Feeder Safety Depends on YouSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Thank You TAbLE of Contents TAbLE OF CONTENTS cont’d Section F ViiiSection E P127, P125, P107 & P289 SeriesTechnical Specifications LN-9 GMA and LN-9F GMA Wire FeederWidth Height Mounting the Wire Feed Unit Installing the LN-9 GMA Roll and 4-ROLL ModelsAttaching the Wire Reel Stand Mounting the UnitPower Input CAbLE ASSEMbLY Electrical Connections LN-9 GMA and LN-9F GMARouting the Electrode Figure A.2 Strain Relief Clamp Figure A.3 LN-9F GMA Control bOXInstallation Can kill Figure A.5 Connection of LN-9 GMA to DC-600 Power Sources Figure A.6 Connection of LN-9 GMA to DC-1000 Power Sources 75 76 77 Installation Figure A.9 Connection of LN-9 GMA to V300 Power Sources Machine Grounding Direct Work Lead ConnectionConnecting the GUN CAbLE to the Wire Feeder For GMA GUN CAbLESHooking UP GMA Shielding GAS Cylinder may explode if damagedSafety Precautions Operating InstructionsK424 LN-9 GMA 2-ROLL and K568-1 LN-9 GMA 4-ROLL General DescriptionRecommended Processes and Equipment K436 LN-9F GMA 2-ROLL and K583-1 LN-9F GMA 4-ROLLDC Constant Voltage Power Sources Controls and Settings Operation Operation Avoiding Grounding Lead Protector GLP Shutdown Power Supply FuseCircuit Protection and Automatic Shutdown Circuit bREAKERAutomatic Shutdown Drive Roll Installation Changing Drive Rolls for 2-ROLL Wire FeedersGuide Tube Detail Changing Drive Rolls for 4-ROLL Wire Feeders Large Wire Loading Figure b.7a Threaded Locking CollarLoading a 50-60 Lb .7-27.2 KG. Coil Using K1504-1 Coil Reel Feeding Electrode and bRAKE AdjustmentADJUSTAbLE Wire Reel bRAKE Loading a 50 or 60 Lb. CoilLoading and Feeding 13-14 Lb Innershield Coils K378 Reel Mounting StandIdle Roll Pressure Setting Roll Wire FeedersFor TWO-ROLL Feeders Pressure Adjustment Knob Pulse Power 500, DC650 PRO CV-400, CV-500-I Adjust the Power SourceAdjust the LN-9 GMA Controls DC-250, DC-400, or DC-600Voltage Control Response Starting CharacteristicsRUN-IN Feature Select AccelerationProcedure AT END of Coil Security of Weld Procedure SettingsMaking a Weld Wire Reel Stands and Mountings Optional Equipment and AccessoriesPower Input CAbLE ASSEMbLIES K196, K595, K596 Auxiliary Equipment ContactsSpindle for READI-REELS and 2 I.D. Spools K162-H Attaching the Wire Reel StandsWire Reel Door KIT READI-REEL AdaptersUniversal Wire Reel Stand K1524-1 Wire Feeder Accessories BURNbACK Timer KIT K419Dual Procedure KIT K319 GMA Timer KIT K418Dual Process KIT K317 For Wire Feeders Pulse Power Filter Conversion KIT K442-1Continuous Flux Feed Tank K320 Swivel Platform K178-1Undercarriage K163 K320 Flux Tank LoadingK58 Magnetic Separator Cored Electrode TAbLE C.2 Drive Roll and Guide TUbE KitsKit Roll Solid Steel Electrode Aluminum ElectrodeCoils with 1 Spindle Routine MaintenancePeriodic Maintenance AdapterProper Speed Sensor Module Mounting Figure D.1 Speed Sensor Module LocationFigure D.2 LN-9 GMA Connectors Figure D.2 Switch RequirementsTROUbLESHOOTING TROUbLESHOOTING Guide Wire Feeding PRObLEMSGun trigger will not feed wire. Digital meter is not lit Grounding Lead Protector Shutdown in the Operation section TROUbLESHOOTING Welding PRObLEMS Starting Characteristics LN-9 GMA WIRING WireLN-9F GMA LN-9 GMA Dimension Print LN-9F GMA Dimension Print 1 Wire Drive Unit LN-9F Dimension Print 2 Control bOXPage Precaucion LN-9 GMA Wire Feeder Keep your head out of fumes