Lincoln Electric LN-9F GMA manual Auxiliary Equipment Contacts, Optional Equipment and Accessories

Page 44

C-1

C-1

ACCESSORIES

AUXILIARY EQUIPMENT CONTACTS

The power for 115 volt AC auxiliary equipment can be obtained from the terminals inside the LN-9 GMA con- trol box. The contacts are “hot” whenever the trigger is pressed or the unit is welding. The current draw of this circuit must not exceed 1/4 ampere.

WARNING

TURN THE INPUT POWER TO THE POWER SOURCE OFF AT THE DISCONNECT SWITCH bEFORE PERFORMING THE FOLLOWING WORK.

LN-9 GMA MODEL:

Install 1/4” quick connect terminals to the leads from the auxiliary equipment. Route the leads to the termi- nals marked #32A and #7 which come through the rec- tangular hole in the control section sheet metal near the wire feed motor.

LN-9F GMA 2-ROLL AND 4-ROLL MODELS:

Install terminals for #6 screws to the leads from the auxiliary equipment. Route the leads to the terminals #32A and #7 on the terminal strip on the inside bottom of the control box.

NOTES:

1.The K418 and K419 burnback timer does not delay the opening of the auxiliary equipment contacts. If you want to continue power to auxiliary equipment during the burnback time, this can be accom- plished only if you are using an R3S, DC-400 or DC-600 power source. Connect the 115 volt AC auxiliary equipment leads to #4 and #31 on the power source terminal strip. The auxiliary equip- ment power requirements should not exceed 15 watts.

This alternate connection cannot be used with the DC-250 or CV-400, 500-I Power Sources.

2.If the LN-9 GMA gas solenoid valve is not required, the gas solenoid terminals (#32A and #7A) may be used in conjunction with the K418 GMA Timer Kit to obtain pre-weld and/or post-weld timing functions for 115V AC auxiliary equipment. However, the gas solenoid must be disconnected and the auxil- iary equipment current draw must not exceed 1/4 ampere.

OPTIONAL EQUIPMENT AND ACCESSORIES

POWER INPUT CAbLE ASSEMbLIES (K196, K595, K596)

Required to connect wire feeder to power source. Includes multiconductor control cable and the proper size electrode cable for the welding current to be used. Specify length and maximum welding current.

K196 Input Cable Assemblies - For power sources with terminal strip wire feeder connections and stud output terminals.

K595 Input Cable Assemblies - For power sources with MS-type (Amphenol) wire feeder receptacle and stud output terminals.

K596 Input Cable Assemblies - For power sources with MS-type (Amphenol) wire feeder receptacle and Twist-Mate™ output connectors.

WIRE REEL STANDS AND MOUNTINGS

50-60 Lb. WIRE REEL MOUNTING STAND (K303)

The assembly includes a framework to which is attached the 50-60 lb. wire reel, a mounting spindle, a dust shield, a lift bail, and a cable clamp for fastening the input cable assembly. It is easily mounted to the basic wire feed unit by three bolts. The reel mounting spindle is the pull knob type with a built-in brake.

The brake pad is adjustable for proper braking at low or high wire feed speeds.

50-60 Lb. READI-REEL®MOUNTING STAND (K445)

The assembly includes a framework to which is attached a 2" O.D. spindle with adjustable brake and 50-60 lb. Readi-Reel Adapter. Includes a lift bail and cable clamp for fastening the input cable assembly, and easily mounts to the LN-9 GMA feeder. Does not include dust shield.

Can also be used for up to 60 lb. spools with 2" I.D.

LN-9 GMA and LN-9F GMA Wire Feeder

Image 44
Contents LN-9 GMA and LN-9F GMA Wire Feeder Safety Depends on YouSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Thank You TAbLE of Contents TAbLE OF CONTENTS cont’d Viii Section ESection F P127, P125, P107 & P289 SeriesWidth Height Technical SpecificationsLN-9 GMA and LN-9F GMA Wire Feeder Installing the LN-9 GMA Roll and 4-ROLL Models Attaching the Wire Reel StandMounting the Wire Feed Unit Mounting the UnitRouting the Electrode Power Input CAbLE ASSEMbLYElectrical Connections LN-9 GMA and LN-9F GMA Figure A.2 Strain Relief Clamp Figure A.3 LN-9F GMA Control bOXInstallation Can kill Figure A.5 Connection of LN-9 GMA to DC-600 Power Sources Figure A.6 Connection of LN-9 GMA to DC-1000 Power Sources 75 76 77 Installation Figure A.9 Connection of LN-9 GMA to V300 Power Sources Machine Grounding Direct Work Lead ConnectionConnecting the GUN CAbLE to the Wire Feeder For GMA GUN CAbLESHooking UP GMA Shielding GAS Cylinder may explode if damagedSafety Precautions Operating InstructionsGeneral Description Recommended Processes and EquipmentK424 LN-9 GMA 2-ROLL and K568-1 LN-9 GMA 4-ROLL K436 LN-9F GMA 2-ROLL and K583-1 LN-9F GMA 4-ROLLDC Constant Voltage Power Sources Controls and Settings Operation Operation Power Supply Fuse Circuit Protection and Automatic ShutdownAvoiding Grounding Lead Protector GLP Shutdown Circuit bREAKERAutomatic Shutdown Drive Roll Installation Changing Drive Rolls for 2-ROLL Wire FeedersGuide Tube Detail Changing Drive Rolls for 4-ROLL Wire Feeders Large Wire Loading Figure b.7a Threaded Locking CollarLoading a 50-60 Lb .7-27.2 KG. Coil Using K1504-1 Coil Reel Feeding Electrode and bRAKE AdjustmentADJUSTAbLE Wire Reel bRAKE Loading a 50 or 60 Lb. CoilLoading and Feeding 13-14 Lb Innershield Coils K378 Reel Mounting StandFor TWO-ROLL Feeders Pressure Adjustment Knob Idle Roll Pressure SettingRoll Wire Feeders Adjust the Power Source Adjust the LN-9 GMA ControlsPulse Power 500, DC650 PRO CV-400, CV-500-I DC-250, DC-400, or DC-600Starting Characteristics RUN-IN FeatureVoltage Control Response Select AccelerationMaking a Weld Procedure AT END of CoilSecurity of Weld Procedure Settings Optional Equipment and Accessories Power Input CAbLE ASSEMbLIES K196, K595, K596Wire Reel Stands and Mountings Auxiliary Equipment ContactsAttaching the Wire Reel Stands Wire Reel Door KITSpindle for READI-REELS and 2 I.D. Spools K162-H READI-REEL AdaptersUniversal Wire Reel Stand K1524-1 Wire Feeder Accessories BURNbACK Timer KIT K419GMA Timer KIT K418 Dual Process KIT K317 For Wire FeedersDual Procedure KIT K319 Pulse Power Filter Conversion KIT K442-1Swivel Platform K178-1 Undercarriage K163Continuous Flux Feed Tank K320 K320 Flux Tank LoadingK58 Magnetic Separator TAbLE C.2 Drive Roll and Guide TUbE Kits Kit Roll Solid Steel ElectrodeCored Electrode Aluminum ElectrodeRoutine Maintenance Periodic MaintenanceCoils with 1 Spindle AdapterProper Speed Sensor Module Mounting Figure D.1 Speed Sensor Module LocationFigure D.2 LN-9 GMA Connectors Figure D.2 Switch RequirementsTROUbLESHOOTING TROUbLESHOOTING Guide Wire Feeding PRObLEMSGun trigger will not feed wire. Digital meter is not lit Grounding Lead Protector Shutdown in the Operation section TROUbLESHOOTING Welding PRObLEMS Starting Characteristics LN-9 GMA WIRING WireLN-9F GMA LN-9 GMA Dimension Print LN-9F GMA Dimension Print 1 Wire Drive Unit LN-9F Dimension Print 2 Control bOXPage Precaucion LN-9 GMA Wire Feeder Keep your head out of fumes