Lincoln Electric CV-305 manual Output Connections, Field Installed Options

Page 10

A-3

 

INSTALLATION

A-3

 

 

 

 

FIELD INSTALLED OPTIONS

LN-742 to CV-305

 

For installation of compatible field installed options (see the ACCESSORIES section of this manual and refer to the instructions included with those options.

REQUIRED EQUIPMENT-CONTROL CABLE CONNECTIONS

Follow the instructions below which are appropriate for the wire feeder that will be used.

LF-72 to CV-305

a)Turn the CV-305 Power switch to the "OFF" posi- tion.

b)Connect the LF-72 control cable to the wire feed- er receptacle on the CV-305.

c)See OUTPUT CONNECTIONS for connection of work and electrode cables.

LN-7 to CV-305

a)Turn the CV-305 Power switch to the "OFF" posi- tion.

b)Connect the LN-7 control cable to the wire feeder receptacle on the CV-305.

c)See OUTPUT CONNECTIONS for connection of work and electrode cables.

LN-25 to CV-305

a)Turn the CV-305 Power switch to the "OFF" posi- tion.

b)Plug a K484 jumper plug into the CV-305 wire feeder receptacle.

c)See OUTPUT CONNECTIONS for connection of work and electrode cables.

WARNING

The output terminals are energized at all times when the K484 is plugged in.

------------------------------------------------------------------------

a)Turn the CV-305 Power switch to the "OFF" posi- tion.

b)Connect the LN-742 control cable to the wire feeder receptacle on the CV-305.

c)See OUTPUT CONNECTIONS for connection of work and electrode cables.

Connection of Remote Control (K857)

NOTE: The K864 Remote Control Adapter is required to install the K857.

Plug the K864 Remote Control Adapter into the power source's 14-pin receptacle. Plug the K857 Remote Control into the 6-pin receptacle of the K864 adapter. If possible, tape the Remote cable to the heavy output leads, so they can protect the smaller Remote cable from damage and abuse.

OUTPUT CONNECTIONS

Output cables must have Magnum Twist-Mate™ plugs for connection to the CV-305. Order K852-95 for con- necting 2/0-3/0 (70-95 mm2) cables. Refer to S18737 for instructions on installing these plugs.

Use the shortest possible cable lengths. See Table A.1 for recommended cable sizes based on length.

Connect the positive output lead to the terminal marked "+". The negative output lead can be hooked to either the low inductance terminal (marked " ") or the high inductance terminal

(marked " ").

TABLE A.1

Cable Sizes for Combined Lengths of Copper

Electrode and Work Cable

 

Lengths up to

 

 

Machine Size

150 ft

150 to 200 ft

 

 

 

 

 

 

 

 

315 A 100%

2/0 (70mm2)

3/0 (95mm2)

 

 

 

 

 

CV-305

Image 10 Contents
Idealarc CV-305February Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-305Select Suitable Location Safety PrecautionsInput Connections StackingField Installed Options Output ConnectionsParalleling Operating Instructions OperationGeneral Warnings Indicates Warning Information Located On Right Case Side Power Source Operation Operational Features and ControlsDesign Features General DescriptionControls and Output Settings Thermal Protection Indication LightWire Feeder Voltmeter Switch Starting the Machine Auxiliary PowerOverload Protection Field Installed Options AccessoriesFactory Installed OPTIONS/ACCESSORIES Compatible Lincoln EquipmentSafety Precautions MaintenanceGeneral Maintenance Machine and Circuit ProtectionTroubleshooting HOW to USE Troubleshooting GuideBUILT-IN Diagnostic Routines and Error Codes Error Code Trouble RemedyMachine Troubleshooting Guide Problems Possible Recommended SymptomsProblems Possible Recommended Poor arc characteristics Control PC Board defective Options Troubleshooting Guide Contact your local LincolnControl PC Board Meter PC BoardOutput Voltage Fault Protection OperationOptional K857 Remote Control Check Checking Snubber CircuitDiagrams Wiring Diagram CV-305 60HzCV Power Source to AN LN-7 and K857 Adapter Power Source to a K867 / K775 / LN CV Power Source to AN LN-25 Power Source to AN LN-25 / K444-1 Lincoln Power Source to AN LN-742 WireInstallation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire FeedersDimension Print Precaucion Warnung
Related manuals