OPERATION | ||
|
|
|
CONTROLS AND OUTPUT SETTINGS
All operator controls and adjustments are located on the case front of the
FIGURE B.1 - CONTROL AND OUTPUT PANEL
5
4
8
7
6
10
11
1. POWER SWITCH
A
2.VOLTAGE ADJUST
Controls the
3. THERMAL PROTECTION INDICATION LIGHT
Indicates that the protection thermostat has activated. The digital meter will display "E10" when this occurs. When the light turns off, the machine will be capable of supplying welding out- put power again.
NOTE: Leaving the power switch in the "ON" posi- tion will result in the most rapid cooling.
4. VOLTS/AMPS SWITCH
Selects either output current or arc voltage to be displayed on the digital meter.
5. DIGITAL VOLTMETER/AMMETER
Displays the
3
1
2
9
13
12
NOTE: Due to voltage drops in the welding cables and at cable connection points, the actual arc voltage may be lower than that displayed on the voltmeter. Use welding cables of the proper capacity and make sure all connec- tions are tight to minimize this effect.
6. 42 VOLT CIRCUIT BREAKER
Protects the 42 volt
7. 115 VOLT CIRCUIT BREAKER
Protects the 115 volt
8. LOCAL/REMOTE SWITCH
Determines whether the welding voltage is con- trolled at the