OPERATION

B-4

 

 

 

CONTROLS AND OUTPUT SETTINGS

All operator controls and adjustments are located on the case front of the CV-305. Refer to Figures B.1.

FIGURE B.1 - CONTROL AND OUTPUT PANEL

5

4

8

7

6

10

11

1. POWER SWITCH

Atwo-position toggle switch.Controls the input power to the CV-305.

2.VOLTAGE ADJUST

Controls the CV-305 output voltage.

3. THERMAL PROTECTION INDICATION LIGHT

Indicates that the protection thermostat has activated. The digital meter will display "E10" when this occurs. When the light turns off, the machine will be capable of supplying welding out- put power again.

NOTE: Leaving the power switch in the "ON" posi- tion will result in the most rapid cooling.

4. VOLTS/AMPS SWITCH

Selects either output current or arc voltage to be displayed on the digital meter.

5. DIGITAL VOLTMETER/AMMETER

Displays the CV-305 output current, or the arc voltage.

3

1

2

9

13

12

NOTE: Due to voltage drops in the welding cables and at cable connection points, the actual arc voltage may be lower than that displayed on the voltmeter. Use welding cables of the proper capacity and make sure all connec- tions are tight to minimize this effect.

6. 42 VOLT CIRCUIT BREAKER

Protects the 42 volt 41-42 circuit in the wire feeder receptacle from overloads and shorts. If this circuit breaker opens, the CV-305 will work normally. However, any equipment powered by the 42 volt circuit will not work.

7. 115 VOLT CIRCUIT BREAKER

Protects the 115 volt 31-32 circuit in the wire feed- er receptacle from overloads and shorts. If this cir- cuit breaker opens, the CV-305 will work normally. However, any equipment powered by the 115 volt circuit will not work.

8. LOCAL/REMOTE SWITCH

Determines whether the welding voltage is con- trolled at the CV-305, or controlled remotely by a remote output control (such as a K857).

CV-305

Image 15 Contents
Idealarc CV-305February California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Idealarc CV-305 InstallationStacking Safety PrecautionsInput Connections Select Suitable LocationOutput Connections Field Installed OptionsParalleling Operation Operating InstructionsGeneral Warnings Indicates Warning Information Located On Right Case Side General Description Operational Features and ControlsDesign Features Power Source OperationThermal Protection Indication Light Controls and Output SettingsWire Feeder Voltmeter Switch Auxiliary Power Starting the MachineOverload Protection Compatible Lincoln Equipment AccessoriesFactory Installed OPTIONS/ACCESSORIES Field Installed OptionsMachine and Circuit Protection MaintenanceGeneral Maintenance Safety PrecautionsHOW to USE Troubleshooting Guide TroubleshootingError Code Trouble Remedy BUILT-IN Diagnostic Routines and Error CodesProblems Possible Recommended Symptoms Machine Troubleshooting GuideProblems Possible Recommended Poor arc characteristics Control PC Board defective Contact your local Lincoln Options Troubleshooting GuideMeter PC Board Control PC BoardChecking Snubber Circuit Fault Protection OperationOptional K857 Remote Control Check Output VoltageWiring Diagram CV-305 60Hz DiagramsCV Power Source to AN LN-7 and K857 Adapter Power Source to a K867 / K775 / LN CV Power Source to AN LN-25 Power Source to AN LN-25 / K444-1 Wire Lincoln Power Source to AN LN-742Installation Instructions TWIST-MATE Cable Plug Installation Instructions Feeders Connection of NON-LINCOLN WireDimension Print Precaucion Warnung