C-1

ACCESSORIES

C-1

 

 

 

FACTORY INSTALLED

OPTIONS/ACCESSORIES

There are no factory installed options/accessories on the CV-305.

FIELD INSTALLED OPTIONS

REMOTE VOLTAGE CONTROL (K857)(1)

The K857 consists of a control box with 25 feet (7.6

m)of four conductor cable. Installation of a K857 Remote Voltage Control in the CV-305 requires a K864 Remote Control Adapter. Refer to the instruc- tions provided with the K857 for hookup to the CV- 305. When properly connected, and with the CV-305 Local-Remote Switch in the "Remote" position, the K857 functions the same as the CV-305 Voltage Adjust control, enabling minimum to maximum output voltage adjustment of the CV-305.

(1)Also availible is a K857-1 w/6 Pin MS-Type (Amphenol) Plug and 100 feet (30.4m) cable.

TWO-CYLINDER UNDERCARRIAGE (K874)

Platform type undercarriage that can accommodate either one or two gas bottles, or one gas bottle and a Magnum water cooler. The CV-305 lifting eye is not functional when the K874 undercarriage is installed.

UNIVERSAL ADAPTER (K867)

Provides a means of connecting auxiliary equipment to the wire feeder receptacle on the CV-305 power source. Consists of a 14-pin MS-type (Amphenol) plug with 8 inch (0.2 meter) long flex leads, one for each circuit present in the wire feeder receptacle. Not required when using a standard wire feeder input cable, such as a K480, with a Lincoln wire feeder.

TWIST-MATE CABLE PLUG (MALE)

• For 1/0-2/0 (50-70 mm2) Cable

(K852-70)

• For 2/0-3/0 (70-95 mm2) Cable

(K852-95)

TWIST-MATE CABLE RECEPTACLE (FEMALE)

• For 1/0-2/0 (50-70 mm2) Cable

(K1759-70)

• For 2/0-3/0 (70-95 mm2) Cable

(K1759-95)

COMPATIBLE LINCOLN EQUIPMENT

The CV-305 is intended for use with the LF-72, LN-7, LN-742, and LN-25 wire feed units. Use the Cables / Kits listed below to make connection easily:

LF-72

Requires K1797-XX

 

Control Cable(Included with

 

Wire Feeder)

 

 

LN-7 / LN-7GMA

Requires K480 Input Cable

 

 

LN-25

Requires K484 Jumper Plug Kit

 

 

LN-25 w/K444-1

Requires K864 Remote Control

Remote Voltage

Adapter and K484 Jumper Plug

Control Kit

Kit

 

 

LN-742 / LN-742H

Requires K591 Input Cable

 

 

CV-305

Image 18
Contents Idealarc CV-305February Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-305Select Suitable Location Safety PrecautionsInput Connections StackingField Installed Options Output ConnectionsParalleling Operation Operating InstructionsGeneral Warnings Indicates Warning Information Located On Right Case Side Power Source Operation Operational Features and ControlsDesign Features General DescriptionControls and Output Settings Thermal Protection Indication LightWire Feeder Voltmeter Switch Auxiliary Power Starting the MachineOverload Protection Field Installed Options AccessoriesFactory Installed OPTIONS/ACCESSORIES Compatible Lincoln EquipmentSafety Precautions MaintenanceGeneral Maintenance Machine and Circuit ProtectionTroubleshooting HOW to USE Troubleshooting GuideBUILT-IN Diagnostic Routines and Error Codes Error Code Trouble RemedyMachine Troubleshooting Guide Problems Possible Recommended SymptomsProblems Possible Recommended Poor arc characteristics Control PC Board defective Options Troubleshooting Guide Contact your local LincolnControl PC Board Meter PC BoardOutput Voltage Fault Protection OperationOptional K857 Remote Control Check Checking Snubber CircuitDiagrams Wiring Diagram CV-305 60HzCV Power Source to AN LN-7 and K857 Adapter Power Source to a K867 / K775 / LN CV Power Source to AN LN-25 Power Source to AN LN-25 / K444-1 Lincoln Power Source to AN LN-742 WireInstallation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire FeedersDimension Print Precaucion Warnung