INSTALLATION

A-4

 

 

 

 

Install the barbed fitting and union nut to the 58-18 female inert gas fitting on the front panel of the LN-25 case. Connect the 316” I.D. gas hose from the gun cable to the barbed fitting.

When the gun is to be removed, this fitting can be easily detached by loosening the union nut.

WELD CABLE CONNECTION

The size of the electrode cable and work cable must be sufficient for the maximum weld current and total cable length to be used. Refer to table A.1.

TABLE A.1

Weld Current

 

Total Cable Length

 

 

 

 

 

 

 

 

 

60% Duty Cycle

50’-100’

100’-150’ 150’-200’

200’-250’

 

 

 

 

 

200Amps

2 AWG

2 AWG

1 AWG

1/0

300Amps

1 AWG

1 AWG

1/0

2/0

400Amps

2/0

2/0

3/0

3/0

500Amps

2/0

3/0

3/0

4/0

 

 

 

 

 

ELECTRODE CABLE CONNECTION

Route the electrode cable through the oval hole in the lower portion of the LN-25 rear panel. Connect the electrode cable to the LN-25 input stud using the 12” nut provided.

Secure the cable with the strain relief clamp provided. All units are supplied with an optional pigtail for customers that prefer to make a taped and bolted connection externally.

WORK CABLE CONNECTION

Connect a work lead of sufficient size between the proper output stud on the power source and the work. Be sure the connection to the work makes tight metal - to - metal electrical contact . Poor work lead connections can result in poor welding performance.

WIRE FEED DRIVE ROLL AND GUIDE TUBE KITS

WARNING

Turn off power source before installing or changing drive roll and/or guide tubes.

NOTE: The maximum wire sizes the LN-25 will satisfactorily feed are 564” cored and 116” solid electrodes.

The electrode sizes that can be fed with each roll and guide tube are stencilled(1) on each part. Check the kit for proper components. See the instructions, included with the drive roll kit, to install these parts on new machines or replace them on used machines. Refer to table A.2.

TABLE A.2

 

 

Kit

Instructions

 

 

 

Steel Wire Sizes:

 

 

.068-564Cored

KP653-332

L9932

116 (.062) Cored or Solid

-116

 

Steel

 

 

 

(Can also be used for .052)

 

 

.045 and .052 Solid Steel

-.052

 

.045 and .052 Cored

-.052C

 

.035

Solid Steel

-.035S

 

.035

Cored

-.035C

 

.030

Solid Steel

-.030S

 

.025 Solid Steel

-.025S

 

 

 

 

Aluminum Wire Sizes:

KP654-116A

 

116

 

L9932

364

 

-364A

 

.035

 

-.035A

 

 

 

 

 

(1)Drive rolls for only cored electrode sizes are stencilled with a “C” suffix to the wire sizes.

Drive rolls for only solid electrode sizes are stencilled with an “S” suffix to the wire sizes.

Drive rolls for aluminum wire sizes are stencilled with an “A” suffix to the wire sizes.

LN-25

Image 11
Contents LN-25 Portable CV/CC Semiautomatic Wire Feeder California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Table of Contents Installation Power Source Connection Safety PrecautionsFor GMA GUN and Cables INVERTEC, CV300 and Other Newer Lincoln Power SourcesGUN Cable Connection to Feeder CV AdapterWork Cable Connection Wire Feed Drive Roll and Guide Tube KitsWeld Cable Connection Electrode Cable ConnectionWelding Capability OperationGeneral Description Recommended Processes and EquipmentLN-25 Instruments and Controls Electrode Polarity SwitchWire Feed Mode Switch Wire Speed Dial and Range SwitchRemote ARC Voltage Control Optional GAS Post PRE-FLOW Timers OptionalWork Clip Lead AWGMounting 10 to 30 LB Spools Sequence of OperationLoading Electrode Mounting 22 to 30 LB READI-REELCOILSIdle Roll Pressure Setting Loading Wire DriveSetting ARC Sensing Wire Feed Speed VV CC Mode Presetting Wire Feed SpeedSetting Constant Wire Feed Speed CV Mode In/Min Making a WeldWelding Procedure AT END of CoilMotor Overload Shutdown Automatic Protection ShutdownOvervoltage Shutdown Table C.1 AccessoriesLN-25 Option Chart K430-2 GAS Solenoid KIT Accessories Optional AccessoriesK434-1 GAS Flow Timer KIT K443-3 LN-25 Contactor KIT K461 Pulse Power Control CableRemote Output Control Options and Control Cable Assemblies K443-2 LN-25 Contactor KITK625, K626, K627 Remote Control Cable Assembly K433 Power Source Remote BOXK432 Remote Control Cable Assembly K439 Remote Extension Cable AssemblyK444, K444-1 or K444-2 Remote Voltage Control KIT Power SourceCable Type Rating Electrode ConnectionDia. Hole Drive Roll & Guide Tube Wire Sizes Used Kit NoCircuit Protection and Automatic Shutdown MaintenanceRoutine Maintenance Adjusting Speed Sensor ModuleCalibration of LN-25 Wire Speed Dial HOW to USE Troubleshooting Guide TroubleshootingRecommended Course of Action Problems Possible Symptoms CauseFeeding Problems Weld Problems Wiring Diagram Wiring Diagram LN-25 Physical Dimensions DimensionsLN-25 LN-25 Perschutz GroundFuera del área de trabajo Cuerpo Inflammable Votre corpsDesconectar el cable de ali No operar con panel abierto o Keep your head out of fumesGuards off Use ventilation or exhaust to