Lincoln Electric IM620-B manual Accessories Optional Accessories, K430-2 GAS Solenoid KIT

Page 22

C-2

ACCESSORIES

C-2

 

OPTIONAL ACCESSORIES

 

 

WARNING

WARNING

ELECTRIC SHOCK can kill.

Do not operate with covers removed.

Turn off power source before installing or servicing.

Do not touch electrically hot parts.

Turn the input power to the welding power source off at the fuse box before working in the terminal strip.

Only qualified personnel should install, use or service this equipment.

K430-2 GAS SOLENOID KIT

(For Codes above 10500 only)

(Factory Installed on K446 and K449 Models)

The kit permits the LN-25 to be used for Gas Metal Arc Welding (GMAW) processes with a GMA gun cable.

The kit can be used with or without a Remote Output Control option installed in the LN-25 and provides flow of shielding gas:

1.With wire feed, when the gun trigger is closed.

2.Without wire feed, when the kit’s Purge button (located beneath the gas inlet fitting) is pressed.

NOTE: Always shut off the valve at the gas cylinder before making any gas connections to the LN-25.

User must provide a supply of shielding gas, a pres- sure regulator, a flow control valve and a hose from the flow valve to the gas inlet fitting of the LN-25. Install by connecting a supply hose from the gas flow valve outlet to the 58-18 female inert gas fitting on the back panel of the LN-25 case.

The LN-25 can be used with any shielding gas recommended in the electrode’s product literature at a maximum pressure of 60 psi (4.1 bar). This may include gases such as Argon, Helium, Nitrogen and blended gasses such as Ar-He, Ar-N2, Ar-O2, Ar- CO2, CO2, Ar-CO2-O2.

CYLINDER may explode if damaged.

• Keep cylinder upright and chained to support.

Keep cylinder away from areas where it may be damaged.

Never lift welder with cylinder attached.

Never allow welding electrode to touch cylinder.

Keep cylinder away from welding or other live elec- trical circuits.

See American National Standard Z-49.1, “Safety in Welding and Cutting” published by the American Welding Society.

See GMA Gun Cable Gas Connection.

Installation instructions (M19154) are included with the kit.

K434-1 GAS FLOW TIMER KIT

(Requires either a K431-1 Remote Output Control Kit, K460-1 Pulse Power Adapter Kit, K624-1 42V Remote Output Control Kit, or internal contactor K443-1 installed in LN-25).

The K434-1 Gas Flow Timer Kit is used with the LN-25 Gas Solenoid when the LN-25 is equipped with any of the Remote Output Control Options or internal contactor.

T h i s k i t p r o v i d e s t h e f o l l o w i n g g a s f l o w timer functions:

1.Preflow Control - Provides flow of shielding gas to the work before the arc is established. The solenoid valve is energized immediately when the gun trigger is closed, but the time delay before the wire feeder and welding output are energized is adjustable between at least 0 to 1 second.

2.Postflow Control - Provides flow of shielding gas to the work after welding is stopped. Delay of the shut off of the solenoid valve after the gun trigger is released is adjustable between at least 0.5 to 5 seconds.

Installation instructions (M17590) are included with LN-25this kit.

Image 22
Contents LN-25 Portable CV/CC Semiautomatic Wire Feeder Safety California Proposition 65 WarningsElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately Table of Contents Installation Safety Precautions Power Source ConnectionCV Adapter INVERTEC, CV300 and Other Newer Lincoln Power SourcesGUN Cable Connection to Feeder For GMA GUN and CablesElectrode Cable Connection Wire Feed Drive Roll and Guide Tube KitsWeld Cable Connection Work Cable ConnectionRecommended Processes and Equipment OperationGeneral Description Welding CapabilityWire Speed Dial and Range Switch Electrode Polarity SwitchWire Feed Mode Switch LN-25 Instruments and ControlsAWG GAS Post PRE-FLOW Timers OptionalWork Clip Lead Remote ARC Voltage Control OptionalMounting 22 to 30 LB READI-REELCOILS Sequence of OperationLoading Electrode Mounting 10 to 30 LB SpoolsLoading Wire Drive Idle Roll Pressure SettingSetting Constant Wire Feed Speed CV Mode Presetting Wire Feed SpeedSetting ARC Sensing Wire Feed Speed VV CC Mode Making a Weld In/MinProcedure AT END of Coil WeldingOvervoltage Shutdown Automatic Protection ShutdownMotor Overload Shutdown LN-25 Option Chart AccessoriesTable C.1 K434-1 GAS Flow Timer KIT Accessories Optional AccessoriesK430-2 GAS Solenoid KIT K443-2 LN-25 Contactor KIT K461 Pulse Power Control CableRemote Output Control Options and Control Cable Assemblies K443-3 LN-25 Contactor KITK439 Remote Extension Cable Assembly K433 Power Source Remote BOXK432 Remote Control Cable Assembly K625, K626, K627 Remote Control Cable AssemblyType Rating Electrode Connection Power SourceCable K444, K444-1 or K444-2 Remote Voltage Control KITDrive Roll & Guide Tube Wire Sizes Used Kit No Dia. HoleAdjusting Speed Sensor Module MaintenanceRoutine Maintenance Circuit Protection and Automatic ShutdownCalibration of LN-25 Wire Speed Dial Troubleshooting HOW to USE Troubleshooting GuideProblems Possible Symptoms Cause Recommended Course of ActionFeeding Problems Weld Problems Wiring Diagram Wiring Diagram Dimensions LN-25 Physical DimensionsLN-25 LN-25 Inflammable Votre corps GroundFuera del área de trabajo Cuerpo PerschutzUse ventilation or exhaust to Keep your head out of fumesGuards off Desconectar el cable de ali No operar con panel abierto o