Lincoln Electric IM620-B Sequence of Operation, Loading Electrode, Mounting 10 to 30 LB Spools

Page 15

B-4

OPERATION

B-4

 

 

 

 

SEQUENCE OF OPERATION

LOADING ELECTRODE

WARNING

ELECTRIC SHOCK can kill.

Unless an optional output control or internal contactor is used with the LN-25, the electrode circuit is electrically “Hot” when the power source is on.

Turn off the power source while mounting electrode coils.

MOUNTING 22 TO 30 LB READI-REEL®COILS

The LN-25 will require an optional K363-P Readi- Reel® Adapter which is required to load Lincoln 22 to 30 lb Readi-Reel coils.

a. Make certain that the threaded locking collar is tight and securely locks the adapter on the spindle (see figure B.2).

b. Rotate the spindle and adapter so the retaining spring is at the 12 o’clock position.

c.Position the Readi-Reel so that it will rotate in a clockwise direction when feeding (wire is to be dereeled from bottom of the coil).

d.Set one of the Readi-Reel inside cage wires on the slot in the retaining spring tab.

e.Lower the Readi-Reel to depress the retaining spring and align the other inside cage wires with the grooves in the molded adapter.

f.Slide cage all the way onto the adapter until the retaining spring “pops up” fully.

WARNING

Check to be sure the retaining spring has fully returned to the locking position and has securely locked the Readi-Reel cage in place. Retaining spring must rest on the cage, not the welding electrode.

g.To remove Readi-Reel from Adapter, depress re- taining spring tab with thumb while pulling the Readi-Reel cage from the molded adapter with both hands . It is not necessary to remove adapter from spindle.

h.Load wire into wire drive per Loading Wire Drive Section.

MOUNTING 10 TO 30 LB SPOOLS

For 12” Diameter Spools:

a. Remove the locking collar and the Readi-Reel adapter (if so equipped) on the 2” diameter spindle (adapter is not required).

b. Place the spool on the spindle so the brake holding pin enters one of the holes in the back side of the spool. Be sure the wire comes off the spool in a clockwise direction when dereeled from the bottom of the coil.

c. Replace and tighten the locking collar.

d. See Loading Wire Drive section for loading instructions.

For 8” Diameter Spools (Requires optional K468 Spindle Adapter for 8” Spools):

a. Remove the locking collar and the Readi-Reel adapter (if so equipped) on the 2” diameter spindle (adapter is not required).

b. Slide S18221 Spindle Adapter onto the 2” spindle so the brake holding pin enters the adapter pin hole.

c.Place the spool on the spindle so the adapter tab enters one of the holes in the back side of the spool. Be sure the wire comes off the spool in a clockwise direction when dereeled from the bottom of the coil.

d.Replace and tighten the Locking Collar.

e.Load wire into wire drive per Loading Wire Drive Section.

MOUNTING 13 OR 14 LB INNERSHIELD COILS (Requires Optional K435 Spindle Adapter for 14 lb Coils.)

a. Remove the locking collar and the Readi-Reel adapter (if so equipped) on the 2” diameter spindle (adapter is not required).

b. Mount K435 Spindle Adapter and Innershield coil per the Instructions (S18256) included with the

LN-25 K435.

Image 15
Contents LN-25 Portable CV/CC Semiautomatic Wire Feeder California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Table of Contents Installation Power Source Connection Safety PrecautionsFor GMA GUN and Cables INVERTEC, CV300 and Other Newer Lincoln Power SourcesGUN Cable Connection to Feeder CV AdapterWork Cable Connection Wire Feed Drive Roll and Guide Tube KitsWeld Cable Connection Electrode Cable ConnectionWelding Capability OperationGeneral Description Recommended Processes and EquipmentLN-25 Instruments and Controls Electrode Polarity SwitchWire Feed Mode Switch Wire Speed Dial and Range SwitchRemote ARC Voltage Control Optional GAS Post PRE-FLOW Timers OptionalWork Clip Lead AWGMounting 10 to 30 LB Spools Sequence of OperationLoading Electrode Mounting 22 to 30 LB READI-REELCOILSIdle Roll Pressure Setting Loading Wire DrivePresetting Wire Feed Speed Setting Constant Wire Feed Speed CV ModeSetting ARC Sensing Wire Feed Speed VV CC Mode In/Min Making a WeldWelding Procedure AT END of CoilAutomatic Protection Shutdown Overvoltage ShutdownMotor Overload Shutdown Accessories LN-25 Option ChartTable C.1 Accessories Optional Accessories K434-1 GAS Flow Timer KITK430-2 GAS Solenoid KIT K443-3 LN-25 Contactor KIT K461 Pulse Power Control CableRemote Output Control Options and Control Cable Assemblies K443-2 LN-25 Contactor KITK625, K626, K627 Remote Control Cable Assembly K433 Power Source Remote BOXK432 Remote Control Cable Assembly K439 Remote Extension Cable AssemblyK444, K444-1 or K444-2 Remote Voltage Control KIT Power SourceCable Type Rating Electrode ConnectionDia. Hole Drive Roll & Guide Tube Wire Sizes Used Kit NoCircuit Protection and Automatic Shutdown MaintenanceRoutine Maintenance Adjusting Speed Sensor ModuleCalibration of LN-25 Wire Speed Dial HOW to USE Troubleshooting Guide TroubleshootingRecommended Course of Action Problems Possible Symptoms CauseFeeding Problems Weld Problems Wiring Diagram Wiring Diagram LN-25 Physical Dimensions DimensionsLN-25 LN-25 Perschutz GroundFuera del área de trabajo Cuerpo Inflammable Votre corpsDesconectar el cable de ali No operar con panel abierto o Keep your head out of fumesGuards off Use ventilation or exhaust to