Lincoln Electric IM620-B manual Remote Output Control Options and Control Cable Assemblies

Page 23

C-3

ACCESSORIES

C-3

 

 

 

 

K460-1 PULSE POWER ADAPTER KIT (For use with K461 Pulse Power Control Cable.)(No Longer Available)

This kit enables the LN-25 to pulse weld with a Pulse Power 500 power source above Code 9300 (or lower Codes updated with Kit).

The kit includes a Remote PC board with output volt- age control, and control cable receptacle which mount and connect inside the LN-25 control box per the Installation Instructions (L9636) included with the kit.

NOTE: If the K460-1 Pulse Power Adapter Kit is in- stalled but the LN-25 is to be used without the K461 Pulse Power Control Cable Assembly, then the in- structions for returning the unit to across the arc op- eration included with the Installation Instructions (L9636) must be followed.

K461 PULSE POWER CONTROL CABLE

ASSEMBLY (No Longer Available)

(Requires K460-1 Pulse Power Adapter Kit installed in LN-25.)

The K461 control cable assemblies include an elec- trode cable, rated for up to 500 amps 60% duty cycle, and a 9-conductor control cable. The control cable pin connector connects to the LN-25 and the lugged leads connect to the Pulse Power. Available in 25, 50, 75 and 100 ft. lengths.

K443-2 LN-25 CONTACTOR KIT

(For Codes 10500 - 10558 only)

(Factory installed in K449 Model.)

The internal contactor provides “cold” electrode until the gun trigger is pressed, and a fixed burnback time delay to prevent electrode from sticking in the weld crater when the trigger is released. The contactor is rated for use up to 300 amps. A cold inch switch allows the wire to be loaded into the system without being electrically “hot”.

Installation Instructions (L10923) are included with the kit.

NOTE: The K443-2 cannot be used with K431-1 or K624-1 Remote Output Control Kit or K460-1 Pulse Power Adapter Kit. If remote voltage control is desired along with the internal contactor, obtain a K444, K444- 1 or K444-2 Remote Voltage Control Kit.

CAUTION

This kit can only be used with LN-25’s Code 10500- 10558. To prevent possible damage to the LN-25 with internal contactor, do not connect to non-Lincoln TIG or Square Wave power sources. TIG high frequency power should never be applied to the LN-25.

K443-3 LN-25 CONTACTOR KIT

(For Codes above 11100 only)

(Factory installed in K449 Model.)

The internal contactor provides “cold” electrode until the gun trigger is pressed, and a fixed burnback time delay to prevent electrode from sticking in the weld crater when the trigger is released. The contactor is rated for use up to 300 amps. A cold inch switch allows the wire to be loaded into the system without being electrically “hot”.

Installation Instructions (L12319) are included with the kit.

NOTE: The K443-3 cannot be used with K431-1 or K624-1 Remote Output Control Kit or K460-1 Pulse Power Adapter Kit. If remote voltage control is desired along with the internal contactor, obtain a K444, K444- 1 or K444-2 Remote Voltage Control Kit.

CAUTION

This kit can only be used with LN-25’s above Code 11100. To prevent possible damage to the LN-25 with internal contactor, do not connect to non-Lincoln TIG or Square Wave power sources. TIG high frequency power should never be applied to the LN-25.

REMOTE OUTPUT CONTROL OPTIONS AND CONTROL CABLE ASSEMBLIES

Remote Output Control Options are available to pro- vide the LN-25 with the following additional features:

1.“Cold” electrode until the gun trigger is pressed, and a fixed burnback time delay to prevent elec- trode from sticking in the weld crater when the gun trigger is released.

2.Remote (10K ohm rheostat) control of power source output arc voltage level.

K431-1 REMOTE OUTPUT CONTROL KIT

(For use with K432 Remote Control Cable and K433 Power Source Remote Box.)

LN-25

Image 23
Contents LN-25 Portable CV/CC Semiautomatic Wire Feeder California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Sûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Table of Contents Installation Power Source Connection Safety PrecautionsFor GMA GUN and Cables INVERTEC, CV300 and Other Newer Lincoln Power SourcesGUN Cable Connection to Feeder CV AdapterWork Cable Connection Wire Feed Drive Roll and Guide Tube KitsWeld Cable Connection Electrode Cable ConnectionWelding Capability OperationGeneral Description Recommended Processes and EquipmentLN-25 Instruments and Controls Electrode Polarity SwitchWire Feed Mode Switch Wire Speed Dial and Range SwitchRemote ARC Voltage Control Optional GAS Post PRE-FLOW Timers OptionalWork Clip Lead AWGMounting 10 to 30 LB Spools Sequence of OperationLoading Electrode Mounting 22 to 30 LB READI-REELCOILSIdle Roll Pressure Setting Loading Wire DriveSetting ARC Sensing Wire Feed Speed VV CC Mode Presetting Wire Feed SpeedSetting Constant Wire Feed Speed CV Mode In/Min Making a WeldWelding Procedure AT END of Coil Motor Overload Shutdown Automatic Protection Shutdown Overvoltage Shutdown Table C.1 AccessoriesLN-25 Option Chart K430-2 GAS Solenoid KIT Accessories Optional AccessoriesK434-1 GAS Flow Timer KIT K443-3 LN-25 Contactor KIT K461 Pulse Power Control CableRemote Output Control Options and Control Cable Assemblies K443-2 LN-25 Contactor KITK625, K626, K627 Remote Control Cable Assembly K433 Power Source Remote BOXK432 Remote Control Cable Assembly K439 Remote Extension Cable AssemblyK444, K444-1 or K444-2 Remote Voltage Control KIT Power SourceCable Type Rating Electrode ConnectionDia. Hole Drive Roll & Guide Tube Wire Sizes Used Kit NoCircuit Protection and Automatic Shutdown MaintenanceRoutine Maintenance Adjusting Speed Sensor ModuleCalibration of LN-25 Wire Speed Dial HOW to USE Troubleshooting Guide TroubleshootingRecommended Course of Action Problems Possible Symptoms CauseFeeding Problems Weld Problems Wiring Diagram Wiring Diagram LN-25 Physical Dimensions DimensionsLN-25 LN-25 Perschutz GroundFuera del área de trabajo Cuerpo Inflammable Votre corpsDesconectar el cable de ali No operar con panel abierto o Keep your head out of fumesGuards off Use ventilation or exhaust to