Lincoln Electric IM536-D manual Gmaw MIG Welding ARC, Process Selection, For Gmaw MIG Process

Page 23

 

LEARNING TO WELD

 

B-9

 

 

 

 

The “arc stream” is seen in the middle of the picture. This is the electric arc created by the electric current flowing through the space between the end of the wire electrode and the base metal. The temperature of this arc is about 6000°F, which is more than enough to melt metal. The arc is very bright, as well as hot, and cannot be looked at with the naked eye without risking painful injury . The very dark lens, specifically designed for arc welding must be used with the hand or face shield whenever viewing the arc.

The arc melts the base metal and actually digs into it much as water through a nozzle on a garden hose digs into the earth. The molten metal forms a molten pool or crater and tends to flow away from the arc. As it moves away from the arc, it cools and solidifies.

The function of the Innershield cored wire electrode is much more than simply to carry current to the arc. The wire core is composed of fluxes and/or alloying ingre- dients around which a steel sheath has been formed. It is simply a stick electrode turned inside out in a con- tinuous wire form.

The cored wire melts in the arc and tiny droplets of molten metal shoot across the arc into the molten pool. The wire sheath provides additional filler metal for the joint to fill the groove or gap between the two pieces of base metal.

The core materials also melt or burn in the arc and perform several functions. They make the arc stead- ier, provide a shield of smoke-like gas around the arc to keep oxygen and nitrogen in the air away from the molten metal, and provide a flux for the molten pool. The flux picks up impurities and forms the protective slag on top of the weld during cooling.

After running a weld bead, the slag may be removed with a chipping hammer and wire brush . This improves appearance and allows for inspection of the finished weld.

Since machine size and output characteristics limit the size and type of wire electrode which can be used, Lincoln 0.035" (0.9mm) NR-211-MP Innershield elec- trode is recommended for Self-Shielded Flux Cored Arc Welding with this machine.

THE GMAW (MIG) WELDING ARC

Figure B.10 illustrates the GMAW (MIG) welding arc. Solid wire does not contain fluxes or ingredients to form its own shielding and no slag forms to protect the molten weld metal. For this reason, a continuous even flow of shielding gas is needed to protect the molten weld metal from atmospheric contaminants such as oxygen and nitrogen. Shielding gas is supplied through the gun and cable assembly, through the gas nozzle and into the welding zone.

 

 

Gas nozzle

 

Solid wire

Shielding gas

 

electrode

 

 

Base metal

Weld metal

 

 

 

 

 

FIGURE B.10

When comparing the GMAW and FCAW processes, you can see that the principal difference between the two lies in the type of shielding used. GMAW uses gas for shielding, thus we have Gas Metal Arc Welding. FCAW uses the melting or burning of the core ingredi- ents for shielding, and is thus termed Self-Shielded Flux Cored Arc Welding.

The recommended wire for Gas Metal Arc Welding (MIG) is Lincolnweld 0.025” (0.6 mm) L-56 electrode. Lincolnweld” L-56 is capable of welding a wide range of mild steels in all positions, however, more skill is required for out-of-position welding with the GMAW process.

PROCESS SELECTION

By gaining knowledge of the differences between the two processes, you will be able to select the best process for the job you have at hand. In selecting a process, you should consider:

For GMAW (MIG) Process

1.Is most of my welding performed on 16 gauge and lighter materials?

SP-125 PLUS

Image 23 Contents
SP-125 Plus California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéPlease Examine Carton and Equipment For Damage Immediately Thank YouTable of Contents Vii Installation Electric Shock can kill Safety PrecautionsIdentify and Locate Components Stacking Work Clamp InstallationWork Cable Installation Select Suitable LocationGAS Connection GUN InstallationConnecting Gun Cable to the SP-125 Plus Input Connections Gas Solenoid Inlet Fitting Power Input CableRequirements For CSA Rated Output Code Requirements for Input ConnectionsRequirements For Rated Output Requirements For Maximum OutputWelding Sparks can cause fire or explosion Observe all safety information throughout this manualOperation Fumes and Gases can be dangerousWelding Capability Controls and SettingsDesign Features Advantages General DescriptionSequence of Operation Wire LoadingWelding Operations Wire Threading Friction Brake AdjustmentsMaking a Weld Shielding Gas Process Guidelines Changing Machine Over to Feed Other Wire Sizes Cleaning Tip And Nozzle Thermal Protection Wire Feed Overload ProtectionOverload Protection Output OverloadSELF-SHIELDED Fcaw Welding ARC Learning to WeldLearning to Weld ARC-WELDING CircuitFor Gmaw MIG Process Gmaw MIG Welding ARCProcess Selection Butt Welds Common MetalsJoint Types and Positions For Fcaw Innershield ProcessFillet Welds Welding In The Vertical PositionPenetration Correct Welding Position Machine SET UP for the SELF-SHIELDED Fcaw ProcessWelding Techniques for the SELF- Shielded Fcaw Process Vertical-down WeldingCorrect Welding Speed Correct Electrical Stickout ESOPractice Helpful HintsWelding Techniques for the Gmaw MIG Process Machine SET UP for the Gmaw MIG ProcessFigure B.24 To Eliminate Stubbing* in order of importance Troubleshooting WeldsTo Eliminate a Ropy Convex Bead in order of importance To Correct Poor Penetration in order of impor- tanceProper Gun Handling Application Chart K586-1 Deluxe Adjustable Gas Regulator Hose Kit AccessoriesOptional Accessories K1799-1 Argon-Mixed Gas Adjustable Regulator and Hose KitInnershield Fcaw Conversion Replacement PartsRoutine and Periodic MAINTE- Nance MaintenanceMaintenance Safety Precautions Items Requiring no MaintenanceContact Tip Cable Liner Drive Roll GUN and Cable MaintenanceConfiguration of Components in Wire Feeding System For Magnum 100L GUNChanging Drive Roll Changing the Contact TIPLiner trim length for gun with red trigger Magnum 100L Changing LinerFigure D.3 SP-125 Plus GUN Handle PartsHOW to USE Troubleshooting Guide TroubleshootingRecommended Course of Action Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Feeding Problems Welding Problems SP-125 Plus Wiring DiagramsSP-125 Plus SP-125 Plus $700.00 How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Warnung