INSTALLATION

A-8

CONNECTION OF LINCOLN ELECTRIC

WIRE FEEDERS

WARNING

Shut off welder before making any electrical connections.

-------------------------------------------------------------------------------------

CONNECTION OF LN-7, LN-8 OR LN-742 TO THE

AIR VANTAGE® 500

Shut the welder off.

Connect the LN-7, LN-8 OR LN-742 per instructions on the appropriate connection diagram in the DIAGRAMS section.

Set the “WIRE FEEDER VOLTMETER” switch to either “+” or “- ” as required by the electrode being used.

Set the “SELECTOR” switch to the “CV-WIRE” position.

Adjust the “ARC CONTROL” knob to desired Crispness. SOFT for MIG and CRISP for INNERSHIELD.

Set the “WELDING TERMINALS” switch to the “REMOTELY CONTROLLED” position.

Set the “IDLE” switch to the “HIGH” position.

CONNECTION OF LN-15 TO THE AIR VANTAGE® 500

These connections instructions apply to both the LN-15 Across- The-Arc and Control Cable models. The LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.

Shut the welder off.

For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

Across The-Arc Model:

Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.

Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

Set the MODE switch to the "CV-WIRE " position.

Across The-Arc Model:

Set the "WELD TERMINALS" switch to "WELD TERMINALS

ON"

Control Cable Model:

Set the "WELD TERMINALS" switch to "REMOTELY

CONTROLLED"

Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polarity being used.

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the "IDLE" switch to the "AUTO IDLE" position

AIR VANTAGE® 500 CUMMINS

Image 16
Contents AIR Vantage 500 Cummins Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Customer Assistance PolicyTable of Contents Vii Technical Specifications AIR Vantage 500 Cummins K2325-1 InstallationAIR Vantage 500 Cummins Safety Precautions Location / VentilationStoring StackingHigh Temperature Operation LiftingHigh Altitude Operation TowingPRE-OPERATION Engine and Compressor Service Welding Terminals Remote Control Auxiliary Power ReceptaclesStandby Power Connections OutputCompany Connection of LN-7, LN-8 or LN-742 to AIR Vantage Connection of Lincoln Electric Wire FeedersConnection of LN-15 to the AIR Vantage Connection of the LN-25 to the AIR Vantage Terminals onOperation Safety InstructionsGeneral Description Controls and Settings 2OPERATIONB-2Battery Charging Light Idler SwitchOIL Pressure Gauge Engine ProtectionAuxiliary Power Controls Engine Operation BREAK-IN Period Welder OperationAIR Vantage 500 Settings When Using K930-2 TIG Module For Tungsten ElectrodesAuxiliary Power Operation Weld Phase Both 1 and 3 Phase Amps Watts PlusAccessories Optional Field Installed AccessoriesTIG Options K2641-2 Four Wheeled Steerable Yard TrailerRoutine and Periodic Maintenance MaintenanceEngine Maintenance Service Instructions & Installation Tips 2MAINTENANCED-2Fuel Filters Battery HandlingCooling System Welder / Generator Maintenance Troubleshooting HOW to USE Troubleshooting GuideRecommended SymptomsCourse of Action Function Problems Troubleshooting Diagrams 2DIAGRAMSF-2 Connection Diagram AIR Vantage 500 CumminsCommander / K867 / K775 / LN-7 Connection Diagram 4DIAGRAMSF-4 5DIAGRAMSF-5 Connection Diagram Cummins7DIAGRAMSF-7 8DIAGRAMSF-8 9DIAGRAMSF-9 10DIAGRAMSF-10 11DIAGRAMSF-11 12DIAGRAMSF-12 Dimension Print M18962-4Ground MojadaNe laissez ni la peau ni des Inflammable Votre corpsKeep your head out of fumes Guards offRespiración Alimentación de poder de la Guardas quitadas Humos. Utilice ventilación o Servicio Aspiración para gases