Friedrich EQ08N11 DIM Function, Alerts, Wait Icon, Control Panel Lock, External Control Status

Page 14

DIM Function

There are three separate display brightness levels, AUTO, 20% and full (100%). To change the DIM setting, press the Power button for three seconds.

FRR192

The 1 indicates a DIM setting of Auto (factory default on new units). Use

the or buttons to change the setting.

FRR193

The 2 indicates a DIM setting of 20%. Press the TIMER SET button within 15 seconds to save the setting. Button inactivity for more than 15 seconds causes the display to time out and return to the normal operating display.

FRR194

The 3 indicates a DIM setting of 100% (full brightness). Press the TIMER SET (Refer to Figure 8) button within 15 seconds to save the setting. Button inactivity for more than 15 seconds causes the display to time out and return to the normal operating display.

Alerts

When the ¿lter needs to be cleaned or replaced, the CHECKFILTER icon displays.

F

AUTO FAN

SET POINT

CHECK

FILTER

 

 

 

FRR118

The alert can be dismissed by pressing the

 

MODE and

SCHEDULE

for 3 seconds.

 

FAN

TIMER

 

Wait Icon

F

AUTO FAN

SET POINT

FRR120

The wait icon illuminates when the compressor lockout is active.

Control Panel Lock

To lock the front panel controls, press and hold the SPEED +

SCHEDULE buttons

 

FAN

TIMER

for 3 seconds. The lock icon

illuminates to indicate the locked status.

During lockout, none of the control panel buttons will operate.

F

AUTO FAN

SET POINT

To unlock, press and hold the SPEED +

FRR116

SCHEDULE buttons simultaneously for 3

FAN

TIMER

seconds.

 

External Control Status

The $MART icon illuminates to indicate that the system is being controlled

remotely, such as from a smart grid from a power company (for more information, see page 12).

SMART

F

AUTO FAN

SET POINT

$MART

FRR125

WiFi Connection

F

AUTO FAN

SET POINT

FRR126

The icon illuminates to indicate that the system is receiving a Wi-Fi connection (for more information, see page 10).

13

Image 14
Contents Room Air Conditioners Table Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Hazards Introduction Register your air conditioner08 N 1 0 a a Unit IdentificationPerformance Data SQ05N10-A 115 146Fire Hazard Electrical DataElectric Shock Hazard Keep the filter clean Make sure the wiring is adequate for your unitTest the power cord Proper installation of chassis seal gasketKuhl Q Control Panel Operation Kühl Control Options Control Panel Operation Instructions Timer Schedule Button ºF ºC SelectWait Icon DIM FunctionAlerts Control Panel LockTo Turn On the Timer or Schedule Selected Timer or Schedule Options 1 or 2 SelectionTimer Start Time Timer SettingsSet theTimer Stop Time Timer on ScenariosTimer OFF Scenarios Timer Schedule Control BlockRemote Control Operation Auto FAN Continuous Cooling Mode Electronic Control Sequence of OperationCompressor Lock Out Time User Interface Tests Components TestingIf the user interface does not turn on Relay Board TestComponents Testing CON’T Testing the Relay BoardFAN Motor Capacitor Check with Capacitor AnalyzerCapacitor Connections BLOWER/FAN Motor TestDrain PAN Valve Testing the Heating Element Electric Shock HazardHeating Element Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressure410A Sealed Refrigeration System Repairs Refrigerant ChargingRefrigeration Sequence of Operation 410A Sealed Refrigeration System Repairs Freeze Hazard Method Of Charging / RepairsBurn Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Single Phase Resistance Test Ground TestExplosion Hazard Recommended procedure for compressor replacementHigh Temperatures Available Accessories Rotary Compressor Special Troubleshooting and ServiceStandard Filter Cleaning / Installation Instructions Routine Maintenance Routine Maintenance Frosting This is a warm weather applianceCondensation is normal NoisesPage See codes chart on next Error Codes Problem Control Boards ActionTest Mode Page Page Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Controls Wiring Diagram THERMISTORS’ Resistance Values Page Page Following is an example using the heat load form Heat Load FormHeating Load Form Friedrich Room Unit Heat Pumps Infiltration Windows & Doors AVGKühl-Q Kühl-Q Units’ 2012 Parts List Kühl Q-Chassis Service Parts List Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty Technical Support Contact Information Friedrich AIR Conditioning CO