Friedrich SQ05N10, SQ10N10, SQ08N10, SQ06N10, EQ08N11 Set theTimer Stop Time, Timer on Scenarios

Page 17

Set theTimer Stop Time

F

AUTO FAN

SET POINT

FRR144

The display shows a normal system. Press and hold the MIN button (Figure

4)for 3 seconds. Note the Timer start - stop times may be set even when the system is in the Schedule mode.

AM

OFF

FRR145

Use the or button to adjust the hour. Press the TIMER SET button (Figure 4) to advance to the Minutes section.

OFF

FRR146

Use the or button to adjust the minutes. Press the TIMER SET button (Figure 4) within 15 seconds to exit and save the setting. The timer is now set to stop at 11:55 AM. The display returns to normal.

Turning the TIMER ON once the time and day, the start and top times have been set:

TIMER

Press the SCHEDULE button once and let go.

NOTE: See the following TIMER ON/OFF scenarios.

Timer ON Scenarios

Scenario 1

F

AUTO FAN

SET POINT

FRR156

The display shows a normal operating system.

FRR157

If the Timer function is turned ON during the Timer’s OFF time, the icon illuminates. The control system immediately turns the unit OFF.

Scenario 2

F

AUTO FAN

SET POINT

FRR158

The display shows a normal operating system.

F

AUTO FAN

SET POINT

FRR159

If the Timer function is turned ON during the Timer’s ON time, the icon illuminates. The control system immediately turns the unit OFF.

16

Image 17
Contents Room Air Conditioners Table Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Register your air conditioner IntroductionUnit Identification 08 N 1 0 a aSQ05N10-A 115 146 Performance DataFire Hazard Electrical DataElectric Shock Hazard Test the power cord Make sure the wiring is adequate for your unitKeep the filter clean Proper installation of chassis seal gasketKuhl Q Control Panel Operation Kühl Control Options Control Panel Operation Instructions ºF ºC Select Timer Schedule ButtonAlerts DIM FunctionWait Icon Control Panel LockTimer or Schedule Options 1 or 2 Selection To Turn On the Timer or Schedule SelectedTimer Settings Timer Start TimeTimer on Scenarios Set theTimer Stop TimeTimer Schedule Control Block Timer OFF ScenariosRemote Control Operation Auto FAN Continuous Electronic Control Sequence of Operation Cooling ModeCompressor Lock Out Time If the user interface does not turn on Components TestingUser Interface Tests Relay Board TestTesting the Relay Board Components Testing CON’TCapacitor Connections Capacitor Check with Capacitor AnalyzerFAN Motor BLOWER/FAN Motor TestDrain PAN Valve Testing the Heating Element Electric Shock HazardHeating Element Refrigeration Sequence of Operation Refrigeration system under high pressure 410A Sealed System Repair ConsiderationsRefrigerant Charging 410A Sealed Refrigeration System RepairsRefrigeration Sequence of Operation 410A Sealed Refrigeration System Repairs Freeze Hazard Method Of Charging / RepairsBurn Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Ground Test Single Phase Resistance TestExplosion Hazard Recommended procedure for compressor replacementHigh Temperatures Rotary Compressor Special Troubleshooting and Service Available AccessoriesStandard Filter Cleaning / Installation Instructions Routine Maintenance Routine Maintenance Condensation is normal This is a warm weather applianceFrosting NoisesPage See codes chart on next Problem Control Boards Action Error CodesTest Mode Page Page Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Controls Wiring Diagram THERMISTORS’ Resistance Values Page Page Heat Load Form Following is an example using the heat load formInfiltration Windows & Doors AVG Heating Load Form Friedrich Room Unit Heat PumpsKühl-Q Kühl-Q Units’ 2012 Parts List Kühl Q-Chassis Service Parts List Schedule Table with Energy Saving Values AddendumRoom AIR Conditioners Limited Warranty Technical Support Contact Information Friedrich AIR Conditioning CO