ERROR CODES
Error | Problem | Control Board's Action | |
Code | |||
|
| ||
1 | Front Panel Button Stuck For More | Continue to monitor for "OPEN" (Unstuck) switch. Do not process switch | |
Than 20 Seconds | input. | ||
|
2Input Voltage Out of Specification (103 Open all relays until voltage is back within specs. Resume operation - 127 / 187 - 253)
3Indoor Temperature Sensor is Open or Set temp to 75°F in COOLING or 68°F in HEATING. Unit continues to
Shortedoperate
4 | Indoor Coil Temperature Sensor is | Control Board sets temp to a default of 40°F. Override sensor. Unit | |
Open or Shorted | continues to operate. | ||
| |||
5 | Outdoor Coil Temperature Sensor is | Sets temp to 20°F. Override sensor. Continue operation. Use Elec Heat if | |
available for HEATING. If not available use HEAT PUMP if outdoor temp | |||
Open or Shorted | |||
| allows. | ||
|
| ||
|
| Shut down for 5 min. Resume operation for 3 min. Continues to monitor. If |
6Outdoor Coil > (grater than) 175 F test fails 3 times, the unit operation is locked out. Unplug and replug to reset.
7Indoor Coil < (less than) 30 F for 2 Turn compressor off. Run High Fan speed. When coil temp reachs 45°F
consecutive minutesresume operation after lockout time.
8Unit Cycles > (grater than) 9 Times per Continue operation. Continue to monitor. Take no action. Log Only. hour
9 | Unit Cycles < (less than) 3 Times per | Continue operation. Continue to monitor. Take no action. Log Only. | |
Hour | |||
|
| ||
|
| Only used if Electric Heat is available. Run High Speed and Electric heat | |
10 | Room Freeze Protection | until room temp reaches 46°F. Display "FRZ" during operation. Logged | |
|
| Only | |
11 | WallStat Problem or Connection Issue | Unit operates based on standard | |
not operate. (See pages 32 and 68) | |||
12 | Not Applicable | Not Applicable | |
|
|
| |
13 | Not Applicable | Not Applicable | |
|
|
| |
14 | Discharge Air Temperature Sensor is | Override Sensor. Set temp to 75°F. Continue to monitor. Set error code 14 | |
Open or Shorted | ON. | ||
| |||
15 | Not Applicable | Not Applicable |
16Temperature Beyond Operating Limits Ambient temp < (less than) 0°F and ambient temp > (greater than) 130°F. Set error code 16 ON. When cleared return unit to normal.
17 | Equipment Doesn't Meet Minimum | Must have compressor enabled and at least 2 fan speeds | |
Configuration | |||
|
| ||
18 | Not Applicable | Not Applicable | |
|
|
| |
19 | Not Applicable | Not Applicable | |
20 | Not Applicable | Not Applicable | |
|
|
| |
21 | Not Applicable | Not Applicable | |
22 | Outdoor Coil Temperature < 30 F for 2 | Unit will use electric heat to satisfy heating demands until temp is greater | |
consecutive Minutes | than 45°F. Unit must be a Heat Pump with electric heat. | ||
| |||
23 | Not Applicable | Not Applicable |
24
Not Applicable
Not Applicable
|
| Key Sequence |
|
| Action |
| To Access Error Codes | Press the fan speed and key for 3 seconds | |||
| Reset Error Codes & Error History | Press + timer/schedule for 3 seconds |
| ||
When you have entered the Error Codes section, an “E” will appear. Use the up | and down keys to scroll through error codes. | ||||
Only active error codes will display. |
|
|
|