Friedrich SQ10N10, SQ08N10, SQ05N10, SQ06N10, EQ08N11 manual Wiring Diagram

Page 55

ELECTRONIC CONTROLS

COOL WITH ELECTRIC HEAT MODELS

EQ08M11-A

WIRING DIAGRAM

USER INTERFACE

 

 

 

 

 

 

 

INDOOR

 

 

 

 

 

 

 

AMBIENT

 

 

 

 

 

 

 

SENSOR

 

 

 

 

 

 

 

(WHITE)

COMPRESSOR TERMINAL

 

 

 

ORIENTATION MAY VARY.

 

 

 

REFER TO MARKINGS ON

 

 

 

COMPRESSOR.

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR COIL SENSOR (BLUE)

COMPRESSOR

 

RELAY BOARD

INDOOR COIL SENSOR (GREEN)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

C

 

 

 

 

BLUE

 

 

 

 

OVLD

 

BLACK

 

 

S

R

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

LN

BLUE

RED

 

 

BLACK

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

 

 

 

 

 

 

GREEN

FAN

 

BLACK

 

 

 

 

TO INNER

 

 

 

 

 

 

MOTOR

 

 

 

 

 

 

WALL /

WHITE

 

 

 

 

 

 

 

 

 

 

 

MOTOR

 

GREEN

 

 

 

 

 

 

 

 

 

 

MOUNT

WHITE

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

CAPACITOR

C

ORANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

F

M

BROWN

 

 

 

 

 

AN

R

 

 

 

 

 

 

E

 

 

 

 

 

BLUE

 

H

 

 

 

 

 

 

 

 

HEATER

 

 

 

 

 

 

 

SUPPLY CORD

L1

TO ECONTROL BRACKET

SCHEMATIC

 

 

 

 

 

 

NEUTRAL

L1 115 VAC

 

 

 

 

 

 

 

 

 

HIGH

 

 

 

 

 

 

1

 

 

 

R

 

 

 

 

MEDIUM

OVLD

 

FAN MTR

 

 

 

2

 

 

 

 

 

 

 

 

 

 

FAN

COM

 

 

LOW

 

 

S

 

 

 

 

 

 

 

 

 

 

 

CAP

 

 

3

ELECTRIC HEAT

 

 

 

 

 

 

 

 

 

 

 

 

5

HL

HTR

TF

 

 

 

 

 

 

 

 

COM

NO

OVLD

 

R

 

 

 

 

 

 

 

 

C

COMPRESSOR

 

 

 

5

 

 

 

 

 

 

 

 

 

HERM

COM

 

 

 

 

 

S

 

 

 

 

 

 

 

ELECTRONIC CONTROL

 

 

 

 

CAP

L E G E N D

CAP

- CAPACITOR

COMPR - COMPRESSOR

MTR

- FAN MOTOR

OLP

- OVERLOAD PROTECTOR

UI

- USER INTERFACE

TF

- THERMAL FUSE

HL

- HEATER LIMIT FUSE

T

-THERMISTER

-COMBINATION TERMINAL

-GROUNDED LEAD SYMBOL

-INSULATOR

PART NO.

REV.

92120002

01

54

Image 55
Contents Room Air Conditioners Table Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Register your air conditioner IntroductionUnit Identification 08 N 1 0 a aSQ05N10-A 115 146 Performance DataElectric Shock Hazard Electrical DataFire Hazard Proper installation of chassis seal gasket Make sure the wiring is adequate for your unitTest the power cord Keep the filter cleanKuhl Q Control Panel Operation Kühl Control Options Control Panel Operation Instructions ºF ºC Select Timer Schedule ButtonControl Panel Lock DIM FunctionAlerts Wait IconTimer or Schedule Options 1 or 2 Selection To Turn On the Timer or Schedule SelectedTimer Settings Timer Start TimeTimer on Scenarios Set theTimer Stop TimeTimer Schedule Control Block Timer OFF ScenariosRemote Control Operation Auto FAN Continuous Electronic Control Sequence of Operation Cooling ModeCompressor Lock Out Time Relay Board Test Components TestingIf the user interface does not turn on User Interface TestsTesting the Relay Board Components Testing CON’TBLOWER/FAN Motor Test Capacitor Check with Capacitor AnalyzerCapacitor Connections FAN MotorHeating Element Testing the Heating Element Electric Shock HazardDrain PAN Valve Refrigeration Sequence of Operation Refrigeration system under high pressure 410A Sealed System Repair ConsiderationsRefrigerant Charging 410A Sealed Refrigeration System RepairsRefrigeration Sequence of Operation 410A Sealed Refrigeration System Repairs Burn Hazard Method Of Charging / RepairsFreeze Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Ground Test Single Phase Resistance TestHigh Temperatures Recommended procedure for compressor replacementExplosion Hazard Rotary Compressor Special Troubleshooting and Service Available AccessoriesStandard Filter Cleaning / Installation Instructions Routine Maintenance Routine Maintenance Noises This is a warm weather applianceCondensation is normal FrostingPage See codes chart on next Problem Control Boards Action Error CodesTest Mode Page Page Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Controls Wiring Diagram THERMISTORS’ Resistance Values Page Page Heat Load Form Following is an example using the heat load formInfiltration Windows & Doors AVG Heating Load Form Friedrich Room Unit Heat PumpsKühl-Q Kühl-Q Units’ 2012 Parts List Kühl Q-Chassis Service Parts List Schedule Table with Energy Saving Values AddendumRoom AIR Conditioners Limited Warranty Technical Support Contact Information Friedrich AIR Conditioning CO