Let’s check out how to control your air conditioner. On the control panel, just above the POWER , is a liquid crystal display (LCD). All of the control panel function buttons and mode icons can be viewed in Figure 6.

Power On – Press the button to turn on the air conditioner. The power button illuminates to indicate that the power is on. The backlight on the power switch will automatically dim to 20% intensity after 15 seconds of inactivity. The remote control can also be used to turn power ON / OFF (See Remote Control).

Display – The display is a high ef¿ciency LCD with a built-in white backlight. The backlight has an automatic two (2) step dim function. After 15 seconds of inactivity, the display dims to 20% intensity. After an additional 120 seconds, the display switches off. Touching any button automatically changes the display to full brightness.

There are three control push buttons on each side of the display.

Figure 2

SYSTEM:

Cycles between

HEAT, COOL or

FAN ONLY

FAN MODE:

Sets fan to either:

-Cycle automatically

-Run continuously

FAN SPEED: Sets fan speed:

LOW, MED, HIGH or AUTO

(as equipped)

ON / OFF: Turns unit on/off

 

 

FAN

 

CONTROL

 

 

 

COOL

HEAT

ONLY

LOCKED

 

 

WI-FI

 

 

 

 

 

 

 

OPERATING (if equipped)

 

 

 

 

 

 

 

TEMPERATURE:

 

 

 

 

 

 

 

Increment UP

 

 

 

88

 

WAIT

 

 

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

AUTO FAN

 

 

 

F

3 MINUTES

 

 

 

 

C

TIME DELAY

 

 

 

 

 

 

 

 

CONTINUOUS

 

 

 

AM

TEMPERATURE:

 

 

 

 

 

 

PM

 

 

 

 

SET POINT

 

ON OFF

Increment DOWN

 

 

 

 

SCHEDULE

 

 

 

 

 

ROOM TEMP

SCHEDULE ON

 

 

 

 

 

 

 

 

 

 

CHECK $MART

 

 

 

AUTO SPEED

 

 

 

 

 

 

FILTER

 

 

 

 

 

 

 

 

 

 

TIMER / SCHEDULE

 

 

 

 

 

 

 

Turns ON or OFF

 

 

 

 

 

 

 

TIMER ON

 

IR WINDOW:

 

Do not block

FILTER

2 DIGIT DISPLAY

Check / Clean

Shows Setting for:

AUTO SPEED

- Set Point (Temperature)

- Room Temperature

Automatically selects

- Clock (AM/PM)

best fan cooling or heating speed

FAN SPEED

SMART OPERATING

Selected fan speed

(see page 10)

8



Image 10
Contents Room Air Conditioners Table Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Hazards Introduction Register your air conditioner08 N 1 0 a a Unit IdentificationPerformance Data SQ05N10-A 115 146Electric Shock Hazard Electrical DataFire Hazard Keep the filter clean Make sure the wiring is adequate for your unitTest the power cord Proper installation of chassis seal gasketKuhl Q Control Panel Operation Kühl Control Options Control Panel Operation Instructions Timer Schedule Button ºF ºC SelectWait Icon DIM FunctionAlerts Control Panel LockTo Turn On the Timer or Schedule Selected Timer or Schedule Options 1 or 2 SelectionTimer Start Time Timer SettingsSet theTimer Stop Time Timer on ScenariosTimer OFF Scenarios Timer Schedule Control BlockRemote Control Operation Auto FAN Continuous Cooling Mode Electronic Control Sequence of OperationCompressor Lock Out Time User Interface Tests Components TestingIf the user interface does not turn on Relay Board TestComponents Testing CON’T Testing the Relay BoardFAN Motor Capacitor Check with Capacitor AnalyzerCapacitor Connections BLOWER/FAN Motor TestHeating Element Testing the Heating Element Electric Shock HazardDrain PAN Valve Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressure410A Sealed Refrigeration System Repairs Refrigerant ChargingRefrigeration Sequence of Operation 410A Sealed Refrigeration System Repairs Burn Hazard Method Of Charging / RepairsFreeze Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Single Phase Resistance Test Ground TestHigh Temperatures Recommended procedure for compressor replacementExplosion Hazard Available Accessories Rotary Compressor Special Troubleshooting and ServiceStandard Filter Cleaning / Installation Instructions Routine Maintenance Routine Maintenance Frosting This is a warm weather applianceCondensation is normal NoisesPage See codes chart on next Error Codes Problem Control Boards ActionTest Mode Page Page Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Controls Wiring Diagram THERMISTORS’ Resistance Values Page Page Following is an example using the heat load form Heat Load FormHeating Load Form Friedrich Room Unit Heat Pumps Infiltration Windows & Doors AVGKühl-Q Kühl-Q Units’ 2012 Parts List Kühl Q-Chassis Service Parts List Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty Technical Support Contact Information Friedrich AIR Conditioning CO