Friedrich EQ08N11, SQ10N10, SQ08N10, SQ05N10, SQ06N10 manual Refrigeration System Hazards

Page 4

% Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, and sleeve on the room side of the air conditioning unit while cleaning.

% Electrical component malfunction caused by water could result in electric shock or other electrically unsafe conditions when the power is restored and the unit is turned on, even after the exterior is dry.

% Never operate the A/C unit with wet hands.

% 8VHDLUFRQGLWLRQHURQDVLQJOHGHGLFDWHGFLUFXLWZLWKLQWKHVSHFL¿HGDPSHUDJHUDWLQJ % Use on a properly grounded outlet only.

% Do not remove ground prong of plug.

% Do not cut or modify the power supply cord. % Do not use extension cords with the unit.

% Follow all safety precautions and use proper and adequate protective safety aids such as: gloves, goggles, clothing, adequately insulated tools, and testing equipment etc.

% )DLOXUHWRIROORZSURSHUVDIHW\SURFHGXUHVDQGRUWKHVHZDUQLQJVFDQUHVXOWLQVHULRXVLQMXU\RUGHDWK

REFRIGERATION SYSTEM HAZARDS:

% Use approved standard refrigerant recovering procedures and equipment to relieve pressure before opening system for repair.

% Do not allow liquid refrigerant to contact skin. Direct contact with liquid refrigerant can result in minor WRPRGHUDWHLQMXU\

% %HH[WUHPHO\FDUHIXOZKHQXVLQJDQR[\DFHW\OHQHWRUFK'LUHFWFRQWDFWZLWKWKHWRUFK¶VÀDPHRUKRW surfaces can cause serious burns.

% 0DNHVXUHWRSURWHFWSHUVRQDODQGVXUURXQGLQJSURSHUW\ZLWK¿UHSURRIPDWHULDOV % +DYHD¿UHH[WLQJXLVKHUDWKDQGZKLOHXVLQJDWRUFK

% 3URYLGHDGHTXDWHYHQWLODWLRQWRYHQWRIIWR[LFIXPHVDQGZRUNZLWKDTXDOL¿HGDVVLVWDQWZKHQHYHU possible.

% Always use a pressure regulator when using dry nitrogen to test the sealed refrigeration system for OHDNVÀXVKLQJHWF

% Make sure to follow all safety precautions and to use proper protective safety aids such as: gloves, safety glasses, clothing etc.

% )DLOXUHWRIROORZSURSHUVDIHW\SURFHGXUHVDQGRUWKHVHZDUQLQJVFDQUHVXOWLQVHULRXVLQMXU\RUGHDWK

MECHANICAL HAZARDS:

% ([WUHPHFDUHSURSHUMXGJPHQWDQGDOOVDIHW\SURFHGXUHVPXVWEHIROORZHGZKHQWHVWLQJ troubleshooting, handling, or working around unit with moving and/or rotating parts.

% Be careful when, handling and working around exposed edges and corners of sleeve, chassis, and

RWKHUXQLWFRPSRQHQWVHVSHFLDOO\WKHVKDUS¿QVRIWKHLQGRRUDQGRXWGRRUFRLOV

% Use proper and adequate protective aids such as: gloves, clothing, safety glasses etc.

% )DLOXUHWRIROORZSURSHUVDIHW\SURFHGXUHVDQGRUWKHVHZDUQLQJVFDQUHVXOWLQVHULRXVLQMXU\RUGHDWK

3

Image 4
Contents Room Air Conditioners Table Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Hazards Introduction Register your air conditioner08 N 1 0 a a Unit IdentificationPerformance Data SQ05N10-A 115 146Electric Shock Hazard Electrical DataFire Hazard Make sure the wiring is adequate for your unit Test the power cordKeep the filter clean Proper installation of chassis seal gasketKuhl Q Control Panel Operation Kühl Control Options Control Panel Operation Instructions Timer Schedule Button ºF ºC SelectDIM Function AlertsWait Icon Control Panel LockTo Turn On the Timer or Schedule Selected Timer or Schedule Options 1 or 2 SelectionTimer Start Time Timer SettingsSet theTimer Stop Time Timer on ScenariosTimer OFF Scenarios Timer Schedule Control BlockRemote Control Operation Auto FAN Continuous Cooling Mode Electronic Control Sequence of OperationCompressor Lock Out Time Components Testing If the user interface does not turn onUser Interface Tests Relay Board TestComponents Testing CON’T Testing the Relay BoardCapacitor Check with Capacitor Analyzer Capacitor ConnectionsFAN Motor BLOWER/FAN Motor TestHeating Element Testing the Heating Element Electric Shock HazardDrain PAN Valve Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressure410A Sealed Refrigeration System Repairs Refrigerant ChargingRefrigeration Sequence of Operation 410A Sealed Refrigeration System Repairs Burn Hazard Method Of Charging / RepairsFreeze Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Single Phase Resistance Test Ground TestHigh Temperatures Recommended procedure for compressor replacementExplosion Hazard Available Accessories Rotary Compressor Special Troubleshooting and ServiceStandard Filter Cleaning / Installation Instructions Routine Maintenance Routine Maintenance This is a warm weather appliance Condensation is normalFrosting NoisesPage See codes chart on next Error Codes Problem Control Boards ActionTest Mode Page Page Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Controls Wiring Diagram THERMISTORS’ Resistance Values Page Page Following is an example using the heat load form Heat Load FormHeating Load Form Friedrich Room Unit Heat Pumps Infiltration Windows & Doors AVGKühl-Q Kühl-Q Units’ 2012 Parts List Kühl Q-Chassis Service Parts List Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty Technical Support Contact Information Friedrich AIR Conditioning CO