Friedrich SQ05N10, SQ10N10, SQ08N10, SQ06N10, EQ08N11 manual Table Of Contents

Page 2

Table Of Contents

 

Important Safety Information

2-4

Introduction

4

8QLW,GHQWL¿FDWLRQ

Performance Data

6

&KDVVLV6SHFL¿FDWLRQV

Installation Information/Sleeve Dimensions

6

Electrical Data

7

Before Operating the Unit

8

)RU%HVW&RROLQJ3HUIRUPDQFHDQG(QHUJ\(I¿FLHQF\

.XKO4&RQWURO3DQHO2SHUDWLRQDQG6\PEROV,GHQWL¿FDWLRQ

Kuhl Q Control Options

10

Control Panel Operation Instructions

11-17

5HPRWH&RQWURO2SHUDWLRQ

Electronic Control Sequence of Operation

20-21

Components Testing

22-25

Refrigeration Sequence of Operation

26

R-410A Sealed System Repair Considerations

27

Sealed Refrigeration System Repairs

28-33

Compressor Checks

34-35

Compressor Replacement

36-37

Available Accessories

37

Standard Filter Cleaning/Installation Instructions

38

5RXWLQH0DLQWHQDQFH

After Maintenance/Repair Start-Up Checklist and Notes

41

Performance Test Data Sheet

42

How to Check the Diagnostic Codes

43

Erasing Diagnostic Codes

43

Error Codes

44

Compressor Test Mode

45

Troubleshooting

46-52

Wiring Diagrams

53-54

Thermistor Resistance Values

55

Instructions for using Cooling Load Estimate Form

56

Cooling Load Estimate Form

57

+HDW/RDG)RUP

Parts List

60-62

Addendum 1

63

Warranty

64

Parts Depots

65

Technical Assistance

65

1

Image 2
Contents Room Air Conditioners Table Of Contents Important Safety Information Your safety and the safety of others are very importantRefrigeration System Hazards Introduction Register your air conditioner08 N 1 0 a a Unit IdentificationPerformance Data SQ05N10-A 115 146Fire Hazard Electrical DataElectric Shock Hazard Keep the filter clean Make sure the wiring is adequate for your unitTest the power cord Proper installation of chassis seal gasketKuhl Q Control Panel Operation Kühl Control Options Control Panel Operation Instructions Timer Schedule Button ºF ºC SelectWait Icon DIM FunctionAlerts Control Panel LockTo Turn On the Timer or Schedule Selected Timer or Schedule Options 1 or 2 SelectionTimer Start Time Timer SettingsSet theTimer Stop Time Timer on ScenariosTimer OFF Scenarios Timer Schedule Control BlockRemote Control Operation Auto FAN Continuous Cooling Mode Electronic Control Sequence of OperationCompressor Lock Out Time User Interface Tests Components TestingIf the user interface does not turn on Relay Board TestComponents Testing CON’T Testing the Relay BoardFAN Motor Capacitor Check with Capacitor AnalyzerCapacitor Connections BLOWER/FAN Motor TestDrain PAN Valve Testing the Heating Element Electric Shock HazardHeating Element Refrigeration Sequence of Operation 410A Sealed System Repair Considerations Refrigeration system under high pressure410A Sealed Refrigeration System Repairs Refrigerant ChargingRefrigeration Sequence of Operation 410A Sealed Refrigeration System Repairs Freeze Hazard Method Of Charging / RepairsBurn Hazard Undercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Single Phase Resistance Test Ground TestExplosion Hazard Recommended procedure for compressor replacementHigh Temperatures Available Accessories Rotary Compressor Special Troubleshooting and ServiceStandard Filter Cleaning / Installation Instructions Routine Maintenance Routine Maintenance Frosting This is a warm weather applianceCondensation is normal NoisesPage See codes chart on next Error Codes Problem Control Boards ActionTest Mode Page Page Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Controls Wiring Diagram THERMISTORS’ Resistance Values Page Page Following is an example using the heat load form Heat Load FormHeating Load Form Friedrich Room Unit Heat Pumps Infiltration Windows & Doors AVGKühl-Q Kühl-Q Units’ 2012 Parts List Kühl Q-Chassis Service Parts List Addendum Schedule Table with Energy Saving ValuesRoom AIR Conditioners Limited Warranty Technical Support Contact Information Friedrich AIR Conditioning CO