Friedrich SQ10N10, SQ08N10, SQ06N10, EQ08N11 manual Performance Data, SQ05N10-A 115 146

Page 7

PERFORMANCE DATA *

 

COOLING

EVAP. AIR TEMP. DEG. F

CONDENSER

 

 

 

 

Discharge Temp

 

PERFORMANCE DATA**

Discharge Air

Temp.

TEMPERATURE DEG. F

 

 

 

 

Drop F.

 

 

 

 

 

 

 

 

SQ05N10-A

57

23

115

146

Chassis-Q

SQ06N10-A

57

23

115

146

SQ08N10-A

58

23

118

158

 

 

SQ10N10-A

53

22

122

164

 

EQ08N11-A

53

27

117

159

 

 

 

OPERATING PRESSURES

ELECTRICAL RATINGS

R-410A

 

BREAKER FUSE

 

 

 

REF.

 

Suction Temp

Super Heat

Sub-Cooling

 

 

 

 

 

Voltage

 

Suction

Discharge

Amps Cool

Amps Heat

Locked Rotor

Charge in

60 Hertz Amps

 

 

 

 

 

 

 

 

 

 

 

Amps

OZ.

 

 

63

10

13

158

387

9

 

29.0

17.0

115

15

63

10

13

150

387

4.9

 

29.0

17.0

115

15

63

12

20

147

415

6.6

 

32.0

22.0

115

15

58

11

23

136

428

9.2

 

50.0

23.5

115

15

61

20

19

146

411

6.7

11.2

32.0

18.5

115

15

*'XHWRFRQWLQXLQJUHVHDUFKLQQHZHQHUJ\VDYLQJWHFKQRORJ\SHUIRUPDQFHGDWDDQGWKDQGWKFKDUDFWHUDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFH 5DWLQJ&RQGLWLRQVGHJUHHV)URRPDLUWHPS UHODWLYHKXPLGLW\ZLWKGHJUHH)RXWVLGHDLUWHPS UHODWLYHKXPLGLW\DOOV\VWHPVXVH5$

 

 

 

 

 

 

 

 

 

Energy

Estimated

 

Room Side

 

 

 

 

 

 

 

 

 

 

 

 

Yearly

Moisture

Air

Net

 

 

Cooling

Heating

Volts

Cooling

Cooling

Heating

Heating

 

Ratio

Operating

Removal

Circulation

Weight

Ship

Model

Capacity Btu

Capacity Btu

Rated

Amps

Watts

Amps

Watts

COP

EER

Cost

Pints/HR

CFM

Sleeve Lbs

Wt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Kühl ®

SQ05N10*

5500

115

4.5

514

 

10.7

$41

0,5

190

Q

65

78

SQ06N10*

5900

115

4.9

561

 

18.7

$45

0.5

190

Q

71

84

SQ08N10*

7500

115

6.1

700

 

10.7

$56

1.2

240

Q

71

84

SQ10N10*

9500

115

8.4

969

 

9.8

$77

2.1

240

Q

75

88

Kühl+® Electric Heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EQ08N11*

7500

4000

115

6.9

765

11.2

1290

1.9

11.7

$61

1.9

175

Q

72

84

As an ENERGY STAR® partner, Friedrich Air Conditioning Co. has determined that the selected ENERGY STAR® models meet the ENERGY STAR®

Estimated yearly operating cost based on a 2007 national average electricity cost of 10.65 cents per kWh.

C US

Installation Information / Sleeve Dimensions

 

 

 

 

Depth

Shell Depth to

 

 

 

 

 

 

 

Thru-the-wallInstallation

 

 

 

 

 

Minimum

Minimum

Window Width

 

 

Finished Hole

 

 

 

 

 

with Front

Louvers

Extension

Extension

 

 

 

 

 

 

 

Sleeve

Height

Width

 

 

 

 

 

 

 

 

 

 

 

 

 

Into Room*

Outside*

Minimum**

Maximum

Height

Width

Max.Depth

Q

14"

19

"

21 3 8"

8

"

5

"

10

"

22"

42"

14

"

20"

8

*Minimum extensions when mounted in a window.

**Minimum widths achieved using one side curtain assembly as opposed to both in a standard installation.

Circuit Rating / Breaker

 

 

Circuit Rating

Plug

 

WallOutlet

Model

 

Breakeror

Face

PowerCord

 

T-D Fuse

(NEMA#)

Length (ft.)

Appearance

 

 

 

 

 

 

 

 

SQ05N10

*, SQ06N10*,

 

 

7

 

 

 

SQ08N10

*, SQ10N10*

 

 

 

 

 

 

 

 

 

 

 

 

EQ08N11*

125V -15A

5 -15P

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Window Mounting Kits

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat/Cool Models

Kit No.

 

 

 

 

 

 

 

 

 

 

 

 

 

EQ08N11*WIKQ

Friedrich heat/cool models include accessories for thru-the-wall installation only. Window mounting requires use of optional accessory kit as listed above.

Front

(C)

(B)

SIDE VIEW

6

Image 7
Contents Room Air Conditioners Table Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Register your air conditioner IntroductionUnit Identification 08 N 1 0 a aSQ05N10-A 115 146 Performance DataElectric Shock Hazard Electrical DataFire Hazard Proper installation of chassis seal gasket Make sure the wiring is adequate for your unitTest the power cord Keep the filter cleanKuhl Q Control Panel Operation Kühl Control Options Control Panel Operation Instructions ºF ºC Select Timer Schedule ButtonControl Panel Lock DIM FunctionAlerts Wait IconTimer or Schedule Options 1 or 2 Selection To Turn On the Timer or Schedule SelectedTimer Settings Timer Start TimeTimer on Scenarios Set theTimer Stop TimeTimer Schedule Control Block Timer OFF ScenariosRemote Control Operation Auto FAN Continuous Electronic Control Sequence of Operation Cooling ModeCompressor Lock Out Time Relay Board Test Components TestingIf the user interface does not turn on User Interface TestsTesting the Relay Board Components Testing CON’TBLOWER/FAN Motor Test Capacitor Check with Capacitor AnalyzerCapacitor Connections FAN MotorHeating Element Testing the Heating Element Electric Shock HazardDrain PAN Valve Refrigeration Sequence of Operation Refrigeration system under high pressure 410A Sealed System Repair ConsiderationsRefrigerant Charging 410A Sealed Refrigeration System RepairsRefrigeration Sequence of Operation 410A Sealed Refrigeration System Repairs Burn Hazard Method Of Charging / RepairsFreeze Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Compressor Checks Ground Test Single Phase Resistance TestHigh Temperatures Recommended procedure for compressor replacementExplosion Hazard Rotary Compressor Special Troubleshooting and Service Available AccessoriesStandard Filter Cleaning / Installation Instructions Routine Maintenance Routine Maintenance Noises This is a warm weather applianceCondensation is normal FrostingPage See codes chart on next Problem Control Boards Action Error CodesTest Mode Page Page Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Heat / Cool only Room AIR Conditioners Troubleshooting Tips Electronic Controls Wiring Diagram THERMISTORS’ Resistance Values Page Page Heat Load Form Following is an example using the heat load formInfiltration Windows & Doors AVG Heating Load Form Friedrich Room Unit Heat PumpsKühl-Q Kühl-Q Units’ 2012 Parts List Kühl Q-Chassis Service Parts List Schedule Table with Energy Saving Values AddendumRoom AIR Conditioners Limited Warranty Technical Support Contact Information Friedrich AIR Conditioning CO