Friedrich WS10B10 Electronic Control Operation, To adjust fan speed, To set the hour clock

Page 9

ELECTRONIC CONTROL OPERATION

PM

Power

 

 

Fan

 

 

Cool

 

 

 

 

 

 

 

 

Mode

Money Saver®

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

Fan Only

 

 

 

 

 

 

Clock

 

 

 

Timer

Set

Start Time

 

 

 

On/Off

Hour

Stop Time

Temp/Hour

 

 

 

 

 

 

 

 

 

 

PM

2

3

4

 

 

8

 

 

 

 

9

 

Smart

Fan

Mode

 

 

Fan

Speed

14

 

Money

Timer

Set

 

Saver

On/Off

Hour

13

 

 

 

 

10

11

12

 

 

Power1

Cool

Fan Only 6

Heat

7

Clock

Start Time 5

Stop Time

Temp/Hour

Figure1:1:WSWSModelModelcoolcool-only -controllycontrolpa e panel

To start unit

If the air conditioner is installed and plugged into a proper receptacle, it is ready to go. The first time the unit is started, the compressor will delay for three minutes. See Automatic Component Protection on the following page.

1Touch the Power button once. The unit will automatically be in Cool mode with the temperature set at 75°F (24°C) and the fan speed at F1, the sleep setting.

To set mode of operation

When you first turn the unit on, it will be in the Cool mode with constant fan.

Figure2:2:WY/WEModelModelheat-heatcool control-cool controlpa el panel

6WARMER – Touch thebutton to raise the room air temperature.

7Press both the and buttons at the same time to switch the temperature from Fahrenheit (°F) to Celsius (°C). Repeat Step 7 to switch from °C back to °F.

To adjust fan speed

8Touch the Fan Speed button to see the current setting. Touch it again t o change s peed. F1 i s the lowest setting (SLEEP SETTING / LOW), F2 is MEDIUM, and F3 is HIGH.

2On WS cool-only models, touch the Mode button once to activate the MoneySaver® (See item 14 for MoneySaver instructions on WY/WE models).

MoneySaver® is a feature that cycles the fan with the compressor so that the fan does not run all the time. This saves energy and improves dehumidification. MoneySaver® will also run to test the temperature if the off cycle is too long. Or you may prefer constant fan for more air movement. (To return to constant fan, touch the Mode button two more times).

In order to run the fan by itself, do the following:

On WY/WS heat-cool models, touch the Mode button once to activate the Fan Only feature. The Fan Only setting will circulate air in the room without the compressor coming on.

3Continuing from MoneySaver® mode, touch the Mode button once to activate the Fan Only feature (WS cool-only models).

To adjust temperature

4Use the Mode button to select either the Cool or MoneySaver® function (or Heat for WY/WE heat-cool models)

5COOLER – Touch the button to lower the room air temperature.

To activate Smart Fan(WS cool-only models)

9There is a fourth option, SF, when selecting the fan speed. This is the SMART FAN function. SMART FAN DOES NOT OPERATE IN CONJUNCTION WITH THE FAN ONLY MODE.

To activate Smart Fan(WY/WE heat-cool models)

9Press the Smart Fan button to activate the Smart Fan.The light will indicate that this feature is in use.

Smart Fan will adjust the fan speed automatically to maintain the desired comfort level. For example, if the outside doors in your home are opened for an extended period of time, or more people enter a room, Smart Fan may adjust to a higher fan speed to compensate for the increased heat load. This keeps you from having to adjust the fan speed on your own.

To set the hour clock

10Touch t he Set Hour button to see t he c urrent setting. T he number that is displayed is the approximate time (hour only). Use the and buttons to change the settings. BE SURE TO SET A.M. AND P.M. ACCORDINGLY. (P.M. is indicated by a red light in the upper left corner of the display).

8

Image 9
Contents Thru-the-wall Table Of Contents Your safety and the safety of others are very important Important Safety InformationRefrigeration System Hazards Property Damage Hazards IntroductionFriedrich wallmaster Model Number Code Performance Data Sleeve / Chassis DimensionsPlug/Outlet/Circuit Rating Electrical DataElectric Shock Hazard Fire HazardElectronic Control Operation To adjust fan speedTo activate Smart FanWS cool-only models To activate Smart FanWY/WE heat-cool modelsTo set the timer Checking Room TemperatureTo Activate Money Saver WY/WE models To set mode of operation To adjust temperatureTo start unit Testing the Electronic Control Error Code ModeElectronic Control Panel Automatic component protectionError Codes Listing for WE/WY Models Error Codes Listing for WS ModelsReboot the Control Panel E7 Motor Operation E9 Heat Pump FailureCoil Sensors Components TestingFAN Motor FAN Motor TestHeating Element CapacitorsDrain PAN Valve Capacitor Check with Capacitor AnalyzerRefrigeration System Sequence of Operation Refrigeration system under high pressure 410A Sealed System Repair ConsiderationsEquipment Required 410A Sealed Refrigeration System RepairsEquipment Must be Capable Risk of Electric ShockMethod Of Charging / Repairs Burn HazardFreeze Hazard Overcharged Refrigerant Systems Undercharged Refrigerant SystemsRestricted Refrigerant System Metering Device Hermetic Components CheckCheck Valve Capillary Tube SystemsPOSITION, 4 Port Reversing Valve Reversing Valve DESCRIPTION/OPERATIONChecking the Reversing Valve Testing the CoilProcedure For Changing Reversing Valve Touch Test in Heating/Cooling CycleExplosion Hazard Compressor Checks Ground Test Single Phase Resistance TestCompressor Replacement Recommended procedure for compressor replacementHigh Temperatures Rotary Compressor Special Troubleshooting and Service Routine Maintenance Sleeve / Drain Front CoverClearances Date Model Serial Room AIR Conditioner Unit Performance Test Data SheetGeneral Troubleshooting Tips General Troubleshooting Tips Cooling only Room AIR Conditioners Troubleshooting Tips Possible Cause Possible Solution Problem Possible Cause Possible Action HEAT/COOL only Room AIR Conditioners Troubleshooting Tips Heat Pump Troubleshooting Troubleshooting Chart Cooling Troubleshooting Chart Heating Heat PumpProblem Electrical Troubleshooting Chart Heat Pump System Cools When Heating is DesiredYES Malfunction of Valve Normal Function of ValvePage Page Page Installation Accessories Mounting Hardware Provided Wall PreparationDescription QTY MECHANICALCUT/SEVER Hazardhazard Installation RequirementsMECHANICALCUT/SEVER Hazard Installation Instructions for Baffle Adapter KIT BAKCUT/SEVER WallMaster Thru-the-WallMechanical Hazard MECHANICALCUT/SEVER Hazard Installation InstructionsAssembly & Installation Instructions Installation Instructions Subbase for WS, WE & WY Models Installation Instructions Architectural Grille Model AG MECHANICALCUT/SEVER Hazard WALLMASTER≤ THRU-THE-WALL AIR Conditioners Limited Warranty Technical Support Contact Information Page Page Friedrich AIR Conditioning CO