Friedrich CP10, CP12 operation manual How to Install the Unit, Window Requirements

Page 11

How to Install the Unit

1.To prevent vibration and excess noise, make sure the unit is installed securely and firmly

2.Install the unit where the sunlight does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet, as it will prevent heat radiation of the condenser.

Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

Cooled air

30"~60"

Fence

Awning

Heat radiation

About 1/2"

Over 20"

CAUTION: All side louvers of the cabinet must remain exposed and unobstructed to the outside of the structure.

4.Install the unit with a rear, downward slope, so the back is slightly lower than the front (about 1/4" buble on a level). This will force condensation to flow to the outside.

5.Install the unit with the bottom about 30"~60" above the floor level.

Window Requirements

NOTE: All supporting parts should be secured to firm wood, masonry, or metal.

This unit is designed for installation in standard double hung windows with actual opening widths from 27" to 39".

The top and bottom window sash must open sufficiently to allow a clear vertical opening of 16" from the bottom of the upper sash to the window stool.

27" to 39"

 

 

16" min

Stool

(With frame curtain)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interior wall

23 5/8" min.

(Without frame curtain)

Offset

1/2" to 11/4"

Sill

Exterior

9

Image 11
Contents Room Air Conditioner Page Table of Contents For the Best Cooling Performance and Energy Efficiency IntroductionBefore Operating Your Unit Never Do This Always Do This Safety PrecautionsSharp EDGES! The edges of the case can be Sharp Inserting the Remote Control Batteries How to operate your FriedrichControl and Remote Control Operations Vent Control Adjusting the Air Flow Direction Adjusting the Air Flow Direction Drainage Care and MaintenanceHow to remove the air filter Air FilterHardware Location Product FeaturesPositioning the Power cord Window Requirements How to Install the UnitSuggested Tool Requirements Installation Kit ContentsType a screws in each support See Fig Cabinet InstallationScrewType a Power cord With a Type C Tools You Will Need Installation InstructionsImporttant Grounding Instructions Electrical DataNormal Operation Troubleshooting TipsRoom AIR Conditioners Limited Warranty Page Manuel dutilisation Et dinstallation Table des matières Nutilisez Jamais un fil de rallonge Avant dutiliser votre appareilAvertissement Mesures de SécuritéBords Pointus Capteur DE Signal DE Télécommande Fonctionnement de la té lé commandeFonctionnement de la té lé commande Remplacement des piles de la té lé commandeRé glage de l’orientation du dé bit d’air Commande de l’orifice de ventilationRé glage de lorientation du dé bit dair Comment retirer le filtre à air Soins et entretienFiltre à air Positionnement du cordon d’alimentation Installation du maté rielCaracté ristiques particuliè res de l’appareil Dimensions de fenê tre minimales Installation de l’appareilOutils recommandé s Contenu du né cessaire d’installationRebord de fenêtre Angle avant Installation du boîtierVis Type a Cordon Dalimentation Lectriques Outils nécessaires Guide dinstallationInstructions Importantes Relatives À LA Mise À LA Terre Instructions dinstallationLe climatiseur fonctionne normalement et Problè mes fré quents et solutionsGarantie limité e Climatiseurs Friedrich Page Acondicionador de aire Contenidos Antes de poner en funcionamiento su unidad IntroducciónAdvertencia Precaucion Control DE Temperatura Funcionamiento del control remotoFuncionamiento del control remoto Insertar las baterías del control remotoAjustar la direcció n del flujo de aire Ajustar la direcció n del flujo de aireControl de ventilació n Como quitar el filtro de aire Cuidado y mantenimientoFiltro de Aire a DrenajePrecaución Instalació n de la unidadFunciones del producto Instalació n del cable elé ctricaRequisitos de la ventana Có mo instalar la unidadRequisitos sugeridos de las ventanas Contenidos de los conjuntos de instalació nGuía superior Asiento de la ventana Angulo frontal Instalació n del gabineteTornillo Tipo a Cable de alimentación Agregue la abrazadera de fijación con un tornillo Herramientas que Necesitará Instrucciones para la instalació nNstrucciones DE Conexion a Tierra Importantes Datos ElectricosSeguridad electrica Problema Causas posibles Qué hacer Problemas y soluciones habitualesGarantia Limitada -PRIMER AÑ O Friedrich AIR Conditioning CO
Related manuals