Friedrich CP10, CP12 operation manual Cabinet Installation, Type a screws in each support See Fig

Page 13

Cabinet Installation

1. Open the window. Mark a line on center of the window stool.

Carefully place the cabinet on the window stool and align the center mark on the bottom

front with the center line marked in the Upper Guide window stool.

Window stool

Front Angle

Fig. 1

2.Pull the bottom window sash down behind the Upper Guide until they meets.

NOTE: Do not pull the window sash down so tightly that the movement of Frame Curtain is restricted.

3.Loosely assemble the Sill Support using the parts in Fig. 3.

Window Sash

Upper guide

Foam-pe 13

Cabinet

Frame Curtain 1

Foam-pe

Fig. 2

4.Select the position that will place the Sill

Support near the outer most point on sill (See Fig. 4)

NOTE: Be careful when you install the cabinet (Frame Guides are broken easily).

5.Attach the Sill Support to the cabinet track hole in relation to the selected position using

2 -type A screws in each support (See Fig. 4).

INDOOR

Bolt 3

Frame Guide 11

INDOOR

OUTDOOR

Sill Support 2 Nut 4

Fig. 3

Screw(Type A) 5

About 1/2"

Cabinet

OUTDOOR

Fig. 4

11

Image 13
Contents Room Air Conditioner Page Table of Contents Before Operating Your Unit IntroductionFor the Best Cooling Performance and Energy Efficiency Never Do This Always Do This Safety PrecautionsSharp EDGES! The edges of the case can be Sharp Control and Remote Control Operations How to operate your FriedrichInserting the Remote Control Batteries Adjusting the Air Flow Direction Adjusting the Air Flow DirectionVent Control How to remove the air filter Care and MaintenanceAir Filter DrainagePositioning the Power cord Product FeaturesHardware Location Window Requirements How to Install the UnitSuggested Tool Requirements Installation Kit ContentsType a screws in each support See Fig Cabinet InstallationScrewType a Power cord With a Type C Tools You Will Need Installation InstructionsImporttant Grounding Instructions Electrical DataNormal Operation Troubleshooting TipsRoom AIR Conditioners Limited Warranty Page Manuel dutilisation Et dinstallation Table des matières Nutilisez Jamais un fil de rallonge Avant dutiliser votre appareilAvertissement Mesures de SécuritéBords Pointus Fonctionnement de la té lé commande Fonctionnement de la té lé commandeRemplacement des piles de la té lé commande Capteur DE Signal DE TélécommandeRé glage de lorientation du dé bit dair Commande de l’orifice de ventilationRé glage de l’orientation du dé bit d’air Filtre à air Soins et entretienComment retirer le filtre à air Caracté ristiques particuliè res de l’appareil Installation du maté rielPositionnement du cordon d’alimentation Dimensions de fenê tre minimales Installation de l’appareilOutils recommandé s Contenu du né cessaire d’installationRebord de fenêtre Angle avant Installation du boîtierVis Type a Cordon Dalimentation Lectriques Outils nécessaires Guide dinstallationInstructions Importantes Relatives À LA Mise À LA Terre Instructions dinstallationLe climatiseur fonctionne normalement et Problè mes fré quents et solutionsGarantie limité e Climatiseurs Friedrich Page Acondicionador de aire Contenidos Antes de poner en funcionamiento su unidad IntroducciónAdvertencia Precaucion Funcionamiento del control remoto Funcionamiento del control remotoInsertar las baterías del control remoto Control DE TemperaturaControl de ventilació n Ajustar la direcció n del flujo de aireAjustar la direcció n del flujo de aire Filtro de Aire a Cuidado y mantenimientoDrenaje Como quitar el filtro de aireFunciones del producto Instalació n de la unidadInstalació n del cable elé ctrica PrecauciónRequisitos de la ventana Có mo instalar la unidadRequisitos sugeridos de las ventanas Contenidos de los conjuntos de instalació nGuía superior Asiento de la ventana Angulo frontal Instalació n del gabineteTornillo Tipo a Cable de alimentación Agregue la abrazadera de fijación con un tornillo Herramientas que Necesitará Instrucciones para la instalació nSeguridad electrica Datos ElectricosNstrucciones DE Conexion a Tierra Importantes Problema Causas posibles Qué hacer Problemas y soluciones habitualesGarantia Limitada -PRIMER AÑ O Friedrich AIR Conditioning CO
Related manuals
Manual 60 pages 53.53 Kb

CP10, CP12 specifications

The Friedrich CP10 and CP12 are advanced air conditioning units designed to provide optimal cooling and ventilation solutions for various applications. These models are particularly known for their innovative technologies and user-friendly features that prioritize efficiency and comfort.

One of the standout characteristics of both the CP10 and CP12 is their energy efficiency. They are equipped with advanced inverter technology, which allows the units to adjust their power output based on real-time cooling demands. This not only helps to reduce energy consumption but also minimizes noise levels, making these units ideal for residential and commercial settings alike.

The CP10 and CP12 feature a sleek and modern design, ensuring that they blend seamlessly into any environment. Their compact size makes them easy to install and suitable for a variety of spaces, from small rooms to larger commercial areas. Both models come with a built-in digital thermostat, allowing users to set and maintain their desired temperature with precision.

In terms of air filtration, the units are equipped with high-efficiency particulate air (HEPA) filters, which trap dust, allergens, and other airborne particles. This feature significantly improves indoor air quality, making the CP10 and CP12 perfect for users with respiratory issues or allergies. Furthermore, the filters are easily accessible, making maintenance simple and straightforward.

Connectivity is another key feature of the CP10 and CP12. They come with Wi-Fi capabilities, allowing users to control their air conditioning units remotely via a smartphone app. This convenience enables homeowners and business operators to adjust settings, track energy usage, and schedule operation times from anywhere.

Additionally, both models incorporate smart technology that enhances their usability. They can learn user preferences and automatically adjust cooling patterns to optimize comfort while ensuring energy savings. The intuitive user interface allows for easy navigation and customization, accommodating diverse user needs.

Durability is also a hallmark of the Friedrich CP10 and CP12. Constructed with high-quality materials, these units are designed to withstand various environmental conditions, ensuring longevity and reliable performance. The robust build quality minimizes the need for frequent repairs and maintenance, providing peace of mind for users.

In summary, the Friedrich CP10 and CP12 air conditioning units are exemplary models that embody energy efficiency, innovative technology, and user-friendly features. With their advanced cooling capabilities, superior air filtration, connectivity options, and robust design, they serve as ideal solutions for maintaining comfortable indoor environments in both residential and commercial spaces.