Friedrich CP12, CP10 operation manual Adjusting the Air Flow Direction, Vent Control

Page 8

Adjusting the Air Flow Direction

Vent Control

For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air.

Part A

CLOSE VENT OPEN

NOTE : Before using the ventilation feature, position the vent lever by pulling Part A out straight and snapping it into place.

Adjusting the Air Flow Direction

Airflow can be adjusted by changing the direction of the air conditioner's louvers.

• Adjusting Horizontal Air Flow Direction

• Adjusting Vertical Air Flow Direction

Adjusting the vertical louvers left and right will

Adjusting the horizontal louver up and down will

change horizontal airflow.

change vertical airflow. The louver can be

 

adjusted by pressing in at the top or button of the

 

horizontal louver.

Adjusting horizontal air flow

Adjusting vertical air flow

Recommended orientation of louvers

Adjust louvers to face upwards when cooling to maximize cooling efficiency.

ENGLISH

6

Image 8
Contents Room Air Conditioner Page Table of Contents For the Best Cooling Performance and Energy Efficiency IntroductionBefore Operating Your Unit Safety Precautions Never Do This Always Do ThisSharp EDGES! The edges of the case can be Sharp Inserting the Remote Control Batteries How to operate your FriedrichControl and Remote Control Operations Vent Control Adjusting the Air Flow DirectionAdjusting the Air Flow Direction Care and Maintenance How to remove the air filterAir Filter DrainageHardware Location Product FeaturesPositioning the Power cord How to Install the Unit Window RequirementsInstallation Kit Contents Suggested Tool RequirementsCabinet Installation Type a screws in each support See FigScrewType a Power cord With a Type C Installation Instructions Tools You Will NeedElectrical Data Importtant Grounding InstructionsTroubleshooting Tips Normal OperationRoom AIR Conditioners Limited Warranty Page Manuel dutilisation Et dinstallation Table des matières Avant dutiliser votre appareil Nutilisez Jamais un fil de rallongeMesures de Sécurité AvertissementBords Pointus Fonctionnement de la té lé commande Fonctionnement de la té lé commandeRemplacement des piles de la té lé commande Capteur DE Signal DE TélécommandeRé glage de l’orientation du dé bit d’air Commande de l’orifice de ventilationRé glage de lorientation du dé bit dair Comment retirer le filtre à air Soins et entretienFiltre à air Positionnement du cordon d’alimentation Installation du maté rielCaracté ristiques particuliè res de l’appareil Installation de l’appareil Dimensions de fenê tre minimalesContenu du né cessaire d’installation Outils recommandé sInstallation du boîtier Rebord de fenêtre Angle avantVis Type a Cordon Dalimentation Lectriques Guide dinstallation Outils nécessairesInstructions dinstallation Instructions Importantes Relatives À LA Mise À LA TerreProblè mes fré quents et solutions Le climatiseur fonctionne normalement etGarantie limité e Climatiseurs Friedrich Page Acondicionador de aire Contenidos Introducción Antes de poner en funcionamiento su unidadAdvertencia Precaucion Funcionamiento del control remoto Funcionamiento del control remotoInsertar las baterías del control remoto Control DE TemperaturaAjustar la direcció n del flujo de aire Ajustar la direcció n del flujo de aireControl de ventilació n Cuidado y mantenimiento Filtro de Aire aDrenaje Como quitar el filtro de aireInstalació n de la unidad Funciones del productoInstalació n del cable elé ctrica PrecauciónCó mo instalar la unidad Requisitos de la ventanaContenidos de los conjuntos de instalació n Requisitos sugeridos de las ventanasInstalació n del gabinete Guía superior Asiento de la ventana Angulo frontalTornillo Tipo a Cable de alimentación Agregue la abrazadera de fijación con un tornillo Instrucciones para la instalació n Herramientas que NecesitaráNstrucciones DE Conexion a Tierra Importantes Datos ElectricosSeguridad electrica Problemas y soluciones habituales Problema Causas posibles Qué hacerGarantia Limitada -PRIMER AÑ O Friedrich AIR Conditioning CO
Related manuals
Manual 60 pages 53.53 Kb

CP10, CP12 specifications

The Friedrich CP10 and CP12 are advanced air conditioning units designed to provide optimal cooling and ventilation solutions for various applications. These models are particularly known for their innovative technologies and user-friendly features that prioritize efficiency and comfort.

One of the standout characteristics of both the CP10 and CP12 is their energy efficiency. They are equipped with advanced inverter technology, which allows the units to adjust their power output based on real-time cooling demands. This not only helps to reduce energy consumption but also minimizes noise levels, making these units ideal for residential and commercial settings alike.

The CP10 and CP12 feature a sleek and modern design, ensuring that they blend seamlessly into any environment. Their compact size makes them easy to install and suitable for a variety of spaces, from small rooms to larger commercial areas. Both models come with a built-in digital thermostat, allowing users to set and maintain their desired temperature with precision.

In terms of air filtration, the units are equipped with high-efficiency particulate air (HEPA) filters, which trap dust, allergens, and other airborne particles. This feature significantly improves indoor air quality, making the CP10 and CP12 perfect for users with respiratory issues or allergies. Furthermore, the filters are easily accessible, making maintenance simple and straightforward.

Connectivity is another key feature of the CP10 and CP12. They come with Wi-Fi capabilities, allowing users to control their air conditioning units remotely via a smartphone app. This convenience enables homeowners and business operators to adjust settings, track energy usage, and schedule operation times from anywhere.

Additionally, both models incorporate smart technology that enhances their usability. They can learn user preferences and automatically adjust cooling patterns to optimize comfort while ensuring energy savings. The intuitive user interface allows for easy navigation and customization, accommodating diverse user needs.

Durability is also a hallmark of the Friedrich CP10 and CP12. Constructed with high-quality materials, these units are designed to withstand various environmental conditions, ensuring longevity and reliable performance. The robust build quality minimizes the need for frequent repairs and maintenance, providing peace of mind for users.

In summary, the Friedrich CP10 and CP12 air conditioning units are exemplary models that embody energy efficiency, innovative technology, and user-friendly features. With their advanced cooling capabilities, superior air filtration, connectivity options, and robust design, they serve as ideal solutions for maintaining comfortable indoor environments in both residential and commercial spaces.