STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the "Maintenance" section on the preced- ing pages and perform scheduled maintenance as necessary.

2.Set the On/Auto/Off lever to “OFF”.

3.Turn the regulator counterclockwise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Water will condense in the air tank. If not drained,

water will corrode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close the drain or drain valve.

NOTE: If drain valve is plugged, release all air pres- sure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from dam- age (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped)

Store the air compressor in a clean and dry location.

13 - ENG

D23122

Image 13
Contents AIR Compressor Specifications Table of ContentsWarranty Result in death or serious injury Risk of Explosion or FireProperty damage Risk from Flying Objects Risk of BurstingRisk to Breathing Risk of Electrical ShockRisk of Burns Risk of Property Damage When Transporting CompressorRisk from Moving Parts Risk of FallingAssembly AccessoriesGlossary Location of the Air Compressor InstallationGrounding Instructions Extension CordsDescription of Operation OperationHow to Start How to StopBreak-in Procedure Before StartingTo Check Safety Valve MaintenanceTo Drain Tank To Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Storage Problem Cause Correction TroubleshootingProblem Cause Correction Compressor Parts Diagram Diagramme DU Compresseur D’AIR Parts LIST/LISTE DES Pièces Pump Diagram Diagramme DE LA Pompe DU Compresseur Not ILLUSTRATED/NON Illustré Cle No Piéce No DescriptionTableau DES Spécifications Table DES MatièresGarantie Garantie Complète DUN AN SUR LES Compresseurs Dair SearsConserver CES Directives Risque D’EXPLOSION OU D’INCENDIEBlessures ou la mort Risque DE Projection D’OBJETS Risque D’ÉCLATEMENTRisque DE Choc Électrique Risque PAR InhalationRisque Relié AUX Pièces Mobiles Risque DE BrûluresRisque DE Chute Lexique AccessoiresAssemblage Rallonges Emplacement du compresseur dairProtection contre la surtension et protection du circuit NE PAS Utiliser UN ADAPTATEUR. Voir lillustrationDescription du fonctionnement UtilisationRobinet de vidange Système de refroidissement non illustréAvant le démarrage Arrêt de lappareilAvant chaque mise en marche Mise en marcheVérification de la soupape de sûreté EntretienVidange du réservoir Remplacement du régulateur Remplacement ou nettoyage de la soupape de retenueEntretien ET Réglages Rangement Problème Cause Correction DépannageDuite par le compresseur, vous avez Remarque Remarque Call Service and Repair PartsSold by Sears Canada, Inc., Toronto, Ont. M5B 2B8