PROBLEM | CAUSE | CORRECTION |
Knocking Noise. | Defective check valve. | Remove and clean, or replace. |
|
|
|
Compressor is not supplying | Prolonged excessive use of air. | Decrease amount of air usage. |
enough air to operate accessories. |
|
|
| Compressor is not large enough | Check the accessory air require- |
| for air requirement. | ment. If it is higher than the |
|
| SCFM or pressure supplied by |
|
| your air compressor, you need a |
|
| larger compressor. |
| Hole in hose. | Check and replace if required. |
| Check valve restricted. | Remove and clean, or replace. |
| Air leaks. | Tighten fittings. |
|
|
|
Motor will not run. | Fuse blown, circuit breaker | Check fuse box for blown fuse |
| tripped. | and replace as necessary. |
|
| Reset circuit breaker. Do not use a |
|
| fuse or circuit breaker with higher |
|
| rating than that specified for your |
|
| particular branch circuit. |
|
| Check for proper fuse. You should |
|
| use a time delay fuse. |
|
| Check for low voltage problem. |
|
| Check the extension cord. |
|
| Disconnect the other electrical |
|
| appliances from circuit or |
|
| operate the compressor on its |
|
| own branch circuit. |
| Extension cord is wrong length or | Check the extension cord. |
| gauge. |
|
| Loose electrical connections. | Check wiring connection inside |
|
| terminal box. |
| Faulty motor. | Have checked by a Trained |
|
| Service Technician. |
|
|
|
Regulator knob has continuous air | Damaged regulator | Replace |
leak. |
|
|
|
|
|
Regulator will not shut off air out- | Damaged regulator | Replace |
let. |
|
|
|
|
|