Craftsman 919.167242 Know Your Air Compressor, Description of Operation, Regulator

Page 13

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

On/Auto/Off

Pressure

Switch

Switch

 

Safety Valve

 

 

Regulator

Outlet

Tank

Pressure Gauge

Pressure Gauge

 

Universal

 

Quick

 

Connect

 

Bodies

Description of Operation

Become familiar with these controls before operating the unit. On/Auto/Off Switch: Turn this switch ON to provide automatic power to the pressure switch and OFF to remove power at the end of each use.

Pressure Switch: The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less than or equal to the tank pressure.

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Pull the knob out and turn clockwise to increase pressure and counterclockwise to decrease pressure. When the desired pressure is reached push knob in to lock in place.

Universal Quick-Connect Body: The universal quick-connect body accepts the three most popular styles of quick-connect plugs- Industrial, automotive (Tru-flate), and ARO. One hand push-to-connect operation makes connections simple and easy.

13- ENG

A08598

Image 13
Contents AIR Compressor Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Explosion May be required Spray area. An additional length of hoseLocation away from compressor Fire, do not allow the compressor toWhat Could Happen Attachments & AccessoriesAccordance with national and local Safety equipment must be properlyElectrical codes Electrical Grounding Failure to provideResult in serious burns Or attempt maintenance until unit hasHot for several minutes after operation Do not reach around protective shroudsHazard Accessories AccessoriesGlossary Duty CycleContents of Carton AssemblyTools Required for Assembly Installing Handles Wheels, and Molded Foot BumpersLocation of the Air Compressor InstallationGrounding Instructions Plug Grounded Outlets Grounding PinVoltage and Circuit Protection Extension CordsKnow Your Air Compressor OperationDescription of Operation RegulatorBefore Starting Break-in Procedure How to StopDrain Valve Check ValveBefore Each Start-Up How to StartTo Check Safety Valve MaintenanceCustomer Responsibilities To Drain TankTo Replace or Clean Check Valve Service and AdjustmentsOutlet Tube Nut Check Valve Screwdriver Open position nothing is visibleTo Replace Regulator StorageRegulator Arrow Troubleshooting Pressure reading Problem Cause Correction Garantía ContenidoGarantía Total DE UN AÑO DEL Compresor DE Aire Modelo Nº 919.167242 Definiciones DE Normas DE SeguridadResultar en lesiones menores o ModeradasGuarde Estas Instrucciones Instrucciones Importantes DE SeguridadCómo prevenirlo Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónA08598 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Insegura Qué puede occurrir Accesorios GlosarioCiclo DE Servicio AccesoriosContenido del embalaje EnsambladoHerramientas requeridas para el ensamblado Instalación de manijas, ruedas y pie moldeado de reboteCómo Preparar LA Unidad InstalaciónUbicación del compresor de aire Protección del voltaje y del circuito Cables de extensión eléctricaConozca su compresor de aire OperaciónDescripción de operaciones Presión de salida TanqueAntes de poner en marcha Cómo utilizar su unidadCómo detenerla Cómo poner en marcha Antes de cada puesta en marchaResponsabilidades del cliente MantenimientoCómo verificar la válvula de seguridad Cómo drenar el tanquePara reemplazar o limpiar la válvula reguladora Servicio Y AjustesTubo de salida Tuerca Destornillador En posición abierta nada es visibleRegulador Flecha Para reemplazar el reguladorAlmacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasRiesgo Alguna porque se debilitaráDesciende cuando El motor no funciona Repair Protection Agreements Product replacement if your covered product cant be fixedGet it fixed, at your home or ours