TROUBLESHOOTING

Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to

voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.

 

PROBLEM

CAUSE

 

CORRECTION

 

Excessive tank

Pressure switch does not

Move On/Auto/Off lever to

 

pressure - safety

shut off motor when

the "OFF" position, if the

 

valve pops off.

compressor reaches "cut-

outfit does not shut off

 

 

out" pressure.

contact a Trained Service

 

 

 

Technician.

 

 

Pressure switch "cut-out"

Contact a Trained Service

 

 

too high.

Technician.

 

 

 

 

 

 

 

 

 

 

Air leaks at

Tube fittings are not tight

Tighten fittings where air can

 

fittings.

enough.

be heard escaping. Check

 

 

 

fittings with soapy water

 

 

 

solution. Do Not

 

 

 

Overtighten.

 

Air leaks in air

Defective air tank.

Air tank must be replaced.

 

tank or at air

 

Do not repair the leak.

 

tank welds.

 

 

 

 

 

Risk of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bursting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not drill into, weld or

 

 

 

otherwise modify air tank

 

 

 

or it will weaken. The tank

 

 

 

can rupture or explode.

 

 

 

 

 

 

Air leaks

Leaking seal.

Contact a Trained Service

 

between head

 

Technician.

 

and valve plate.

 

 

 

 

 

 

 

 

Air leak from

Possible defect in safety

Operate safety valve

 

safety valve.

valve.

manually by pulling on ring.

 

 

 

If valve still leaks, it should

 

 

 

be replaced.

 

 

 

 

 

 

Knocking Noise.

Possible defect in safety

Operate safety valve

 

 

valve.

manually by pulling on ring.

 

 

 

If valve still leaks, it should

 

 

 

be replaced.

 

 

 

 

 

 

 

 

 

19- ENG

A08598

Image 19
Contents AIR Compressor Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Fire, do not allow the compressor to Spray area. An additional length of hoseExplosion May be required Location away from compressorWhat Could Happen Attachments & AccessoriesElectrical Grounding Failure to provide Safety equipment must be properlyAccordance with national and local Electrical codesDo not reach around protective shrouds Or attempt maintenance until unit hasResult in serious burns Hot for several minutes after operationHazard Duty Cycle AccessoriesAccessories GlossaryInstalling Handles Wheels, and Molded Foot Bumpers AssemblyContents of Carton Tools Required for AssemblyPlug Grounded Outlets Grounding Pin InstallationLocation of the Air Compressor Grounding InstructionsVoltage and Circuit Protection Extension CordsRegulator OperationKnow Your Air Compressor Description of OperationCheck Valve How to StopBefore Starting Break-in Procedure Drain ValveBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Check ValveTo Replace Regulator StorageRegulator Arrow Troubleshooting Pressure reading Problem Cause Correction Garantía ContenidoGarantía Total DE UN AÑO DEL Compresor DE Aire Moderadas Definiciones DE Normas DE SeguridadModelo Nº 919.167242 Resultar en lesiones menores oGuarde Estas Instrucciones Instrucciones Importantes DE SeguridadCómo prevenirlo Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónA08598 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Insegura Qué puede occurrir Accesorios GlosarioAccesorios Ciclo DE ServicioInstalación de manijas, ruedas y pie moldeado de rebote EnsambladoContenido del embalaje Herramientas requeridas para el ensambladoCómo Preparar LA Unidad InstalaciónUbicación del compresor de aire Protección del voltaje y del circuito Cables de extensión eléctricaPresión de salida Tanque OperaciónConozca su compresor de aire Descripción de operacionesAntes de poner en marcha Cómo utilizar su unidadCómo detenerla Cómo poner en marcha Antes de cada puesta en marchaCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadDestornillador En posición abierta nada es visible Servicio Y AjustesPara reemplazar o limpiar la válvula reguladora Tubo de salida TuercaRegulador Flecha Para reemplazar el reguladorAlmacenaje Alguna porque se debilitará Guía DE Diagnóstico DE ProblemasProblema Causa Corrección RiesgoDesciende cuando El motor no funciona Repair Protection Agreements Product replacement if your covered product cant be fixedGet it fixed, at your home or ours