Craftsman 919.167242 Installation, Location of the Air Compressor, Grounding Instructions

Page 11

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

Plug

Grounded

Outlets

Grounding Pin

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

GROUNDING INSTRUCTIONS

Risk of Electrical Shock. In the event

of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical

Shock. Improper grounding can result in electrical shock.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified electrician.

11- ENG

A08598

Image 11
Contents AIR Compressor Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions Fire, do not allow the compressor to Spray area. An additional length of hoseExplosion May be required Location away from compressorWhat Could Happen Attachments & AccessoriesElectrical Grounding Failure to provide Safety equipment must be properlyAccordance with national and local Electrical codesDo not reach around protective shrouds Or attempt maintenance until unit hasResult in serious burns Hot for several minutes after operationHazard Duty Cycle AccessoriesAccessories GlossaryInstalling Handles Wheels, and Molded Foot Bumpers AssemblyContents of Carton Tools Required for AssemblyPlug Grounded Outlets Grounding Pin InstallationLocation of the Air Compressor Grounding InstructionsVoltage and Circuit Protection Extension CordsRegulator OperationKnow Your Air Compressor Description of OperationCheck Valve How to StopBefore Starting Break-in Procedure Drain ValveBefore Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Check ValveRegulator Arrow StorageTo Replace Regulator Troubleshooting Pressure reading Problem Cause Correction Garantía Total DE UN AÑO DEL Compresor DE Aire ContenidoGarantía Moderadas Definiciones DE Normas DE SeguridadModelo Nº 919.167242 Resultar en lesiones menores oCómo prevenirlo Instrucciones Importantes DE SeguridadGuarde Estas Instrucciones Qué puede occurrir Cómo prevenirlo Advertencia Riesgo de ExplosiónA08598 30- SP Advertencia Riesgo de Caída Qué puede occurrir Advertencia Riesgo de Quemaduras Qué puede occurrirAdvertencia Riesgo de Operación Insegura Qué puede occurrir Accesorios GlosarioAccesorios Ciclo DE ServicioInstalación de manijas, ruedas y pie moldeado de rebote EnsambladoContenido del embalaje Herramientas requeridas para el ensambladoUbicación del compresor de aire InstalaciónCómo Preparar LA Unidad Protección del voltaje y del circuito Cables de extensión eléctricaPresión de salida Tanque OperaciónConozca su compresor de aire Descripción de operacionesCómo detenerla Cómo utilizar su unidadAntes de poner en marcha Cómo poner en marcha Antes de cada puesta en marchaCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadDestornillador En posición abierta nada es visible Servicio Y AjustesPara reemplazar o limpiar la válvula reguladora Tubo de salida TuercaRegulador Flecha Para reemplazar el reguladorAlmacenaje Alguna porque se debilitará Guía DE Diagnóstico DE ProblemasProblema Causa Corrección RiesgoDesciende cuando El motor no funciona Repair Protection Agreements Product replacement if your covered product cant be fixedGet it fixed, at your home or ours