Blue Sea Systems P12 user manual

Page 19

Equalization (continued)

P12

7521 AND 7522 BATTERY CHARGERS

8.To change battery, use the up down arrow buttons to scroll the cursor to the Bat1 window.

9.Press the Select button.

10.Using the left and right arrow buttons, scroll between the three different battery banks connected to the charger.

11.Confirm Equalization parameters for the battery you wish to equalize.

12.Using the up down arrow buttons, scroll the cursor to the StartEQ window.

13.Press the Select button.

14.The charger will now begin to equalize and will display.

15.Monitor batteries and battery temperature throughout the Equalization process.

16.You may pause Equalization at any time by pressing the pause button.

17. If at any point during Equalization a DC load is applied to the battery being equalized, Equalization will stop.

NOTE: If you receive the below warning screen confirm batteries are fully charged and all DC loads connected to the batteries are turned off. Once complete proceed back to step 1 of the Equalization process.

18.You may stop Equalization at any time by pressing the stop button. NOTE: Pressing stop will return you to the Charger Summary screen.

19.Once the max Equalization voltage is reached the battery bank will begin to equalize for the designated Equalization time.

20.After the designated Equalization time is met Equalization will stop and the charger will return to the Charger Summary Screen.

Specifications are subject to change. See bluesea.com/P12 for current information.

17

Image 19
Contents P12 Page Table of Contents P12 P12 Battery Charger Overview Charging Specifications Installation Clearances Product DimensionsIncluded Components Accessory PackSocket wrench Supplies NeededRing terminals Installation Steps Installation InstructionsAC Strain Relief Optional Installations see pages Wiring ConnectionsInitial Charger Setup Advanced Charger Setup Reset to Manufacturer Defaults Absorption Parameters and Timers Battery Temperature Compensation Tempco Temperature ParametersMinimum Charge Temperature The default is 0ºC Maximum Charge Temperature The default is 50ºCEqualization Process EqualizationDefinition of Equalization Prior to EqualizationP12 Screen Summary Configuration MenuDisplay Setup Charger SetupSystem Status Hour Meter Temperature ParametersSystem Status Absorb Timers System StatusAlert Screens and Diagnostics DC Fuse AC Input Voltage Too LowAC Input Voltage Too High DC Output Voltage Too HighOptional Connection Fuse Optional InstallationSI ES ES SI Engine ACR Four Control Buttons Optional AccessorySpecifications Cable ConnectionDimensioned Drawing Charge Stage Display IndicatorsFan Mode ChargingButtons Alerts and DiagnosticsRelated Products Warranty and Contact InformationDate of first purchase means Blue Sea Systems Technical SupportP12 Charge Management System Twin Engine980012000 Rev