Blue Sea Systems P12 user manual Specifications

Page 7

 

Specifications

 

P12

 

 

7521 AND 7522 BATTERY CHARGERS

 

 

7521

7522

 

 

Total Output Current

25A

40A

 

 

 

 

 

 

Input AC Current

4.5A @ 100V AC / 2.25A @ 200V AC

7.5A @ 100V AC / 3.75A @ 200V AC

 

 

 

 

 

 

Nominal Output Voltage

12V DC

12V DC

 

 

Output Connections

3 positive, 1 negative

3 positive, 1 negative

 

 

 

 

 

 

Universal AC Input Voltage

90V–265V AC

90V–265V AC

 

 

 

 

 

 

Input Frequency Range

45–65 Hz

45–65 Hz

 

 

Typical Float Voltage

13.5V DC

13.5V DC

 

 

 

 

 

 

Maximum Available Voltage

16.0V DC

16.0V DC

 

 

 

 

 

 

Output Voltage Accuracy

0.05V DC

0.05V DC

 

 

 

 

 

 

Minimum Operating Temperature

−20°C (−4°F)

−20°C (−4°F)

 

 

Maximum Operating Temperature

70°C (158°F)

70°C (158°F)

 

 

 

 

 

 

Minimum Storage Temperature

−30°C (−22°F)

−30°C (−22°F)

 

 

 

 

 

 

Maximum Storage Temperature

80°C (176°F)

80°C (176°F)

 

 

 

 

 

 

Warranty

5 Year

5 Year

 

 

 

 

 

 

Battery Types*

Flooded, Gel, AGM, TPPL (Thin Plate Pure Lead)

Flooded, Gel, AGM, TPPL (Thin Plate Pure Lead)

 

 

 

 

 

 

Recommended for Battery Bank Sizes**

160Ah Minimum, Example: 2 x Group 27

220Ah Minimum, Example: 2 x Group 31

 

330Ah Maximum, Example: 3 x Group 31

440Ah Maximum, Example: 4 x Group 31

 

 

 

*Consult battery manufacturer specifications for other battery types to avoid damage. Do not mix battery types.

**Battery bank sizes are recommended for optimal charging efficiency-see bluesea.com/P12 for details. Larger and smaller size banks could charge well, but consume slightly more power over the charging cycle.

Regulatory

Designed and constructed for compliance to UL-1236 Marine, CSA 22.2 No. 107.2, and ABYC A-31 standards. Ignition Protection per ISO 8846, and SAE J1171. Meets FCC Part 15, Class B requirements. To view current regulatory specifications visit www.bluesea.com/P12.

Table A: Minimum Recommended Wire Size*

Conductor Length in feet (meters)

Charger Rating

 

25A

40A

6 ft (1.83 meters)

14 AWG (2.5mm²)

8 AWG (10mm²)

 

 

 

10 ft (3.05 meters)

12 AWG (4mm²)

8 AWG (10mm²)

 

 

 

15 ft (4.57 meters)

10 AWG (6mm²)

6 AWG (16mm²)

 

 

 

20 ft (6.09 meters)

8 AWG (10mm²)

6 AWG (16mm²)

 

 

 

25 ft (7.62 meters)

6 AWG (16mm²)

4 AWG (25mm²)

Recommended Battery Fuse

30A

60A

*Based on 3% voltage drop. If fast charge recovery is important, use larger wire. Double the conductor length entry to get a 1.5% drop, triple the conductor length to get a 1% voltage drop.

Table D: AC Wire - Circuit Protection Selection Chart

 

7521 (25A)

7522 (40A)

Input Watts

450

750

 

 

 

120V AC Application

4.5A @ 100V AC

7.5A @ 100V AC

 

 

 

Minimum AC Wire Size

18 AWG (0.75mm²)

16 AWG (1.5mm²)

 

 

 

Circuit Breaker

10A

15A

 

 

 

230V AC Application*

2.25A @ 200V AC

3.75A @ 200V AC

 

 

 

Minimum Wire Size

18 AWG (0.75mm²)

18 AWG (0.75mm²)

 

 

 

Circuit Breaker

5A – 10A

5A – 10A

 

 

 

* Typical of Europe

 

 

Table B: Recommended DC Circuit Protection

Appropriate Fuses and Fuse Holders

Charger Rating

Fuse Type

Fuse Holder

25A

40A

MRBF Terminal Fuses

5191 Terminal Fuse Block

5175 (30A Fuse)

5178 (60A Fuse)

 

 

 

 

AMI®/MIDI® Fuses

7720 Safety Fuse Block

5250 (30A Fuse)

5253 (60A Fuse)

 

 

 

 

Table C: Typical AC Regional Wire Colors

Region

Line

Neutral

Ground (Earth)

North America

Black

White

Green

 

 

 

 

Europe

Brown

Blue

Green-Yellow

 

 

 

 

Australia/ New Zealand

Brown or Red

Blue or Black

Green-Yellow

 

 

 

 

Table E: Default Voltages by Battery Type

Batteries should match in chemistry, although many AGM’s and flooded batteries are compatible. Based on 25°C (77°F)

Type

Absorb Volts

Float Volts

FLA – Flooded Lead Acid

14.5V

13.5V

 

 

 

AGM – Absorbed Glass Mat

14.35V

13.3V

 

 

 

Gel – Gelled Electrolyte

14.1V

13.5V

 

 

 

TPPL – Thin Plate Pure Lead

14.7V

13.6V¹

User Adjustable

12.5V Default

12.5V Default

 

 

 

¹Taken from Odyssey Tech Notes, Northstar operation Manual

Specifications are subject to change. See bluesea.com/P12 for current information.

5

Image 7
Contents P12 Page Table of Contents P12 P12 Battery Charger Overview Charging Specifications Installation Clearances Product DimensionsIncluded Components Accessory PackSocket wrench Supplies NeededRing terminals Installation Steps Installation InstructionsAC Strain Relief Optional Installations see pages Wiring ConnectionsInitial Charger Setup Advanced Charger Setup Reset to Manufacturer Defaults Absorption Parameters and Timers Battery Temperature Compensation Tempco Temperature ParametersMinimum Charge Temperature The default is 0ºC Maximum Charge Temperature The default is 50ºCEqualization Process EqualizationDefinition of Equalization Prior to EqualizationP12 Screen Summary Configuration MenuDisplay Setup Charger SetupSystem Status Hour Meter Temperature ParametersSystem Status Absorb Timers System StatusAlert Screens and Diagnostics DC Fuse AC Input Voltage Too LowAC Input Voltage Too High DC Output Voltage Too HighOptional Connection Fuse Optional InstallationSI ES ES SI Engine ACR Four Control Buttons Optional AccessorySpecifications Cable ConnectionDimensioned Drawing Charge Stage Display IndicatorsFan Mode ChargingButtons Alerts and DiagnosticsRelated Products Warranty and Contact InformationDate of first purchase means Blue Sea Systems Technical SupportP12 Charge Management System Twin Engine980012000 Rev