Blue Sea Systems P12 Reset to Manufacturer Defaults, Table E Default Voltages by Battery Type

Page 15

Advanced Charger Setup (continued)

19.Once desired display settings are enabled press Back.

20.Press the left or right arrow button to scroll to the Battery window.

21.Press the Select button.

Table E: Default Voltages by Battery Type

Batteries should match in chemistry, although many AGM’s and flooded batteries are compatible. Based on 25°C (77°F)

Type

Absorb Volts

Float Volts

FLA – Flooded Lead Acid

14.5V

13.5V

 

 

 

AGM – Absorbed Glass Mat

14.35V

13.3V

 

 

 

Gel – Gelled Electrolyte

14.1V

13.5V

 

 

 

TPPL – Thin Plate Pure Lead

14.7V

13.6V¹

User Adjustable

12.5V Default

12.5V Default

 

 

 

¹Taken from Odyssey Tech Notes, Northstar operation Manual

22.While the cursor blinks on battery type press the Select button.

23.Use the left or right arrow buttons to scroll to desired battery type.

24.Press the OK button.

P12

7521 AND 7522 BATTERY CHARGERS

25. For optimal charging it is recommended to set absorption timers and End Absorb Amps. If Amp Hour Capacity is known, continue to page 14 for more information.

NOTE: to adjust Absorb and Float voltage “User” must be the selected battery type. The default Absorb voltages for each battery type can be seen in Table E above.

Warning: Incorrect Absorb and Float voltages could reduce the life of your batteries. Contact your battery manufacturer for recommended Absorb and Float voltages.

CAUTION

Selecting a battery type different from the connected batteries could limit the life of the batteries and damage them.

26.Press the Back button twice to return to the Charger Summary screen.

27.Your P12 Battery Charger is now setup and fully operational.

Reset to Manufacturer Defaults

To reset the P12 Battery Charger to factory defaults, press and hold the two right buttons for ten seconds.

Press the OK button for five seconds to proceed with resetting to factory defaults or press the Cancel button to return to the previous screen. Note: Resetting the P12 Battery Charger to factory defaults will erase previously saved data and settings.

Specifications are subject to change. See bluesea.com/P12 for current information.

13

Image 15
Contents P12 Page Table of Contents P12 P12 Battery Charger Overview Charging Specifications Installation Clearances Product DimensionsIncluded Components Accessory PackSupplies Needed Socket wrenchRing terminals Installation Instructions Installation StepsAC Strain Relief Optional Installations see pages Wiring ConnectionsInitial Charger Setup Advanced Charger Setup Reset to Manufacturer Defaults Absorption Parameters and Timers Battery Temperature Compensation Tempco Temperature ParametersMinimum Charge Temperature The default is 0ºC Maximum Charge Temperature The default is 50ºCEqualization Process EqualizationDefinition of Equalization Prior to EqualizationP12 Screen Summary Configuration MenuDisplay Setup Charger SetupSystem Status Hour Meter Temperature ParametersSystem Status Absorb Timers System StatusAlert Screens and Diagnostics DC Fuse AC Input Voltage Too LowAC Input Voltage Too High DC Output Voltage Too HighOptional Connection Fuse Optional InstallationSI ES ES SI Engine ACR Four Control Buttons Optional AccessorySpecifications Cable ConnectionDimensioned Drawing Charge Stage Display IndicatorsFan Mode ChargingButtons Alerts and DiagnosticsRelated Products Warranty and Contact InformationDate of first purchase means Blue Sea Systems Technical SupportP12 Charge Management System Twin Engine980012000 Rev