Blue Sea Systems user manual Twin Engine, P12 Charge Management System

Page 31

P12 Charge Management System

 

Twin Engine

2

AC ELCI Ground Fault Protection

 

 

 

 

 

System Functions:

 

 

 

 

 

1

AC Amperage, Voltage, and Frequency measurement with alarms

 

 

 

 

 

3

AC Source Selection

 

3 Battery Bank

 

5

DC Battery Charger Remote Monitoring and Control

 

 

 

 

 

4

AC Branch Circuit Protection and Switching

 

 

 

 

 

6

DC Amperage and Voltage measurement with alarms

 

 

 

 

 

7

DC Branch Circuit Protection and Switching

 

 

 

 

 

8

DC Remote Battery Isolation Switching

360 Panel System

 

 

 

 

9

DC Remote Automatic Charging Relay (ACR) Switching

 

 

 

 

10

3 Bank Battery Charging

 

 

 

 

 

11

House Battery Isolation

 

 

 

 

 

12

Engine Battery Isolation

 

5

 

 

13

Charge Distribution Engine 1 – Engine 2 – House

 

 

 

14

Charge Coordination – ACR’s Disabled if Battery Charger Active

 

 

 

 

 

 

 

 

 

 

15

DC Main Circuit Protection

 

 

 

 

 

16

System Ground

 

 

 

 

 

1

6

 

 

 

 

 

 

P12 Battery Charger

 

 

 

 

 

 

10

 

2

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

8

4

9

 

 

 

14

RBS

RBS

ACRs

RBS

Alternator

 

 

Alternator

Engine 1

Starter

11

12

13

13

12

Starter

 

Engine 2

Class-T

Fuse Block

15

 

 

15

15

 

 

AMI®/MIDI® Fuse Block

 

 

 

 

 

 

AMI®/MIDI® Fuse Block

 

 

 

LEGEND

House

Start 1

Start 2

AC Line

 

 

 

DC Positive

 

16

 

System Ground

 

 

 

Control

 

PowerBar (System Ground)

 

 

Specifications are subject to change. See bluesea.com/P12 for current information.

29

Image 31
Contents P12 Page Table of Contents P12 P12 Battery Charger Overview Charging Specifications Installation Clearances Product DimensionsIncluded Components Accessory PackSocket wrench Supplies NeededRing terminals Installation Steps Installation InstructionsAC Strain Relief Optional Installations see pages Wiring ConnectionsInitial Charger Setup Advanced Charger Setup Reset to Manufacturer Defaults Absorption Parameters and Timers Battery Temperature Compensation Tempco Temperature ParametersMinimum Charge Temperature The default is 0ºC Maximum Charge Temperature The default is 50ºCEqualization Process EqualizationDefinition of Equalization Prior to EqualizationP12 Screen Summary Configuration MenuDisplay Setup Charger SetupSystem Status Hour Meter Temperature ParametersSystem Status Absorb Timers System StatusAlert Screens and Diagnostics DC Fuse AC Input Voltage Too LowAC Input Voltage Too High DC Output Voltage Too HighOptional Connection Fuse Optional InstallationSI ES ES SI Engine ACR Four Control Buttons Optional AccessorySpecifications Cable ConnectionDimensioned Drawing Charge Stage Display IndicatorsFan Mode ChargingButtons Alerts and DiagnosticsRelated Products Warranty and Contact InformationDate of first purchase means Blue Sea Systems Technical SupportP12 Charge Management System Twin Engine980012000 Rev