Blue Sea Systems P12 user manual Alert Screens and Diagnostics

Page 22

Alert Screens and Diagnostics

P12

7521 AND 7522 BATTERY CHARGERS

If at any time during the chargers life the red Alert light goes on, then the charger is not providing optimal performance. The below Alerts encompass all of the possibilities for the charger to under perform. Alerts will be indicated by the red Alert light as well as a pop-up screen explaining the reason.

Reverse Polarity or Short Circuit

The P12 Battery Charger has the ability to determine if batteries are incorrectly connected to the charger. Upon supplying AC power to the charger if a reverse polarity or short circuit situation exists the Reverse Polarity or Short Circuit Screen will be displayed. Shut off AC power and correct the connection issue. Once corrected, turn on AC power and attempt to use the battery charger as normal. If no alert screen displays then the charger is

fully operational.

Reverse Polarity or Short

Turn Off AC Power

Check DC Connections

WARNING

If AC power is being supplied to the battery charger and batteries are connected incorrectly (reverse polarity or short circuit), damage will occur to the internals of the battery charger. This will render the battery charger

non-operational. Never make connections while AC power is supplied to the battery charger. Personal and property damage may occur and the chargers warranty will be void.

Thermal Regulation

The P12 Battery Charger is equipped with an intelligent thermal regulation device for safe charging. If at any point during charging a thermometer image begins to blink in the upper right hand corner of the screen, then the charger has entered Thermal Regulation. This is not a failure, but a reduced current output state. While in this state the internal temperature is being regulated by controlling the maximum output current. The maximum output current will appear at the bottom of the Charger Summary Screen indicating the total amount of current available to supply all outputs. While in Thermal Regulation, the charger will reduce output current to keep the charger at a safe operating temperature. The output can be regulated all the way down to zero but is not likely. The most common correction for this state is to increase the fan speed to High. If the fan speed is already set to High check for blockage around the fan vent that can be removed. If the condition persists, it is advisable to reposition the battery charger in a cooler, more ventilated location.

Fan

The P12 Battery Charger is equipped with a variable speed fan. The fan is used to dissipate warm air produced from high output currents during charging. The aluminum case of the P12 Battery Charger provides a large amount of heat dissipation but for optimal performance the fan must be performing properly. If at any point the fan fails to perform at its designated setting the Fan Alert Screen will appear. If this alert screen appears shut off AC power to the battery charger as well as all battery connections. Determine if there is a blockage in or around the fan vent and correct. Turn on AC power and check to see if the Fan Alert Screen appears. If the Fan Alert Screen does not appear and the fan seems to be operating correctly, then continue to use the battery charger normally. If the Fan Alert Screen appears contact Blue Sea Systems for fan replacement instructions.

Fan Fault

Check Fan for Blockage

Battery Temperature Sensor

As discussed in the Temperature Parameters section (page 15), there is an external battery temperature sensor supplied with the unit. If at any point the temperature sensor records a temperature beyond the defined temperature limits, the battery charger will display the Battery Temperature Alert Screen. In this situation all battery charging will stop until the proper battery temperature is restored. Normal operation will not commence unless two degrees within the temperature parameters. For example, if the maximum temperature parameter is set to 50°C and the temperature sensor reads 51°C then the Battery Temperature Alert Screen will display. In this situation the battery charger will not charge until the battery temperature sensor reads a maximum of 48°C. If no temperature sensor is in use then battery temperature is not monitored and this alert will not be displayed.

Battery Temperature

Out of Limits

CAUTION

Alteration of battery temperature parameters without sufficient knowledge is dangerous and can cause personal or property harm. If the battery temperature sensor goes outside a designated parameter, contact your battery manufacturer for further information on specific battery temperatures.

Internal Temperature Sensor

The P12 Battery Charger is equipped with two internal temperature sensors. These sensors are unrelated to the supplied external battery temperature sensor. If the Internal Temperature Sensor Alert Screen appears, then one or more of the internal temperature sensors is not recording correct temperature data. Once in this state all battery charging will stop. This form of temperature alert can not be corrected by the user. Contact Blue Sea Systems for further information regarding internal temperature sensor alerts.

Internal Temp Below -20° C

Charger Will Restart When

Internal Temp Above -18° C

20Specifications are subject to change. See bluesea.com/P12 for current information.

Image 22
Contents P12 Page Table of Contents P12 P12 Battery Charger Overview Charging Specifications Product Dimensions Installation ClearancesAccessory Pack Included ComponentsSocket wrench Supplies NeededRing terminals Installation Steps Installation InstructionsAC Strain Relief Wiring Connections Optional Installations see pagesInitial Charger Setup Advanced Charger Setup Reset to Manufacturer Defaults Absorption Parameters and Timers Maximum Charge Temperature The default is 50ºC Temperature ParametersMinimum Charge Temperature The default is 0ºC Battery Temperature Compensation TempcoPrior to Equalization EqualizationDefinition of Equalization Equalization ProcessP12 Charger Setup Configuration MenuDisplay Setup Screen SummarySystem Status Temperature ParametersSystem Status Absorb Timers System Status Hour MeterAlert Screens and Diagnostics DC Output Voltage Too High AC Input Voltage Too LowAC Input Voltage Too High DC FuseOptional Installation Optional Connection FuseSI ES ES SI Engine ACR Cable Connection Optional AccessorySpecifications Four Control ButtonsDimensioned Drawing Charging Display IndicatorsFan Mode Charge StageAlerts and Diagnostics ButtonsBlue Sea Systems Technical Support Warranty and Contact InformationDate of first purchase means Related ProductsTwin Engine P12 Charge Management System980012000 Rev