Introduction

Load Management The Freedom SW 3000 has a built-in transfer relay that connects your inverter output or AC input from the utility grid or generator to your loads. Because the usual AC power sources such as campground outlets or small generators often have limited current availability, having the capability to manage your AC loads is extremely valuable. The Freedom SW 3000 provides a number of features to facilitate this:

The charger is power factor corrected to use AC current as efficiently as possible and only requires 22 amps to provide rated charger output. Minimizing the AC current used by the charger means more current is available for your AC loads.

Freedom SW 3000 has a power share feature which prioritizes your AC loads by reducing the charge current and maintaining the total input current to less than your breaker setting or the breaker setting.

Occasionally, AC input sources have low voltage. To avoid loading these weak sources any further, the charger automatically reduces its AC current draw as the AC voltage approaches the minimum acceptable level.

Xanbus® System

The Xanbus system includes the Freedom SW 3000 and other Xanbus- enabled devices. The Freedom SW 3000 is the device in a Xanbus system that typically provides network power—500 mA at 12 volts DC. All of the Xanbus-enabled devices, such as the Freedom SW 3000, the System Control Panel (SCP), and the Automatic Generator Starter (AGS) are able to communicate their settings and activity to each other. See Figure 1.

AC Out

AC In

Figure 1 Typical Xanbus System Diagram

4

Freedom SW 3000 Owner’s Guide

Image 18
Contents Freedom SW Sine Wave Inverter/Charger Page Date and Revision About Xantrex TrademarksExclusion for Documentation Document Part NumberAbout This Guide Statement of HazardRelated Information Important Safety Instructions Electrical Shock HazardFire and Burn Hazard Explosion HazardPrecautions When Working With Batteries Exposure to Chemicals and Gases Hazard Precautions When Preparing to ChargePrecautions When Placing the Inverter/Charger Risk of Damage to the INVERTER/CHARGERRegulatory Limitations on USEContents Page Page Page Introduction Materials ListPremium Power and Ease of Use About the Freedom SW Inverter/ChargerHow the Freedom SW 3000 Inverter/Charger Works InvertingCharging Typical Xanbus System Diagram Freedom SW 3000 Owner’s Guide Xanbus SystemProtection feature This feature… Comprehensive Electronic ProtectionFront Panel Controls Status LEDs Freedom SW 3000 Inverter/Charger FeaturesFront and Side Panels Compartment SideThough the transformer and power compartments Two variable-speed cooling fans are used to coolAC wiring compartment access panel with Freedom SWNegative DC terminal connects to the negative Battery temperature sensor BTS jack providesAC and DC Side Panels AC Input 1, AC Input 2, and Inverter AC OutputSupplied Accessories Supplied AccessoriesOptional System Accessories and Network Components AccessoryNetwork Component Operating The Freedom SW Using the SCP 10 9 8Down arrow button On Start UpExit button Up arrow buttonSystem Start-up Check Viewing the Firmware Revision Number To view the firmware revision numberOperating in Invert Mode To operate in invert mode from the front panelOperating Limits for Inverter Operation Operating in Charger Mode Charger Operation with Battery Temperature Sensor BTSOperating in Equalization Mode Risk of Damage to BatteriesRisk of Damage to DC Load Equipment Equalizing BatteriesTerminating the Equalization Process To equalize your batteriesOperating Limits for Charger Operation Monitoring the Freedom SW 3000 Indicator Lights Faults and WarningsMonitoring Status Messages on the SCP System Modes OperatingTo return to Operating mode SafeSafe Mode To exit Safe mode and return to Operating modeConfiguration System Control PanelSystem Menu Map SCP System Menu Map Freedom SW 3000 Owner’s GuideViewing the System Screen Viewing the Select Device MenuTo view the Select Device menu Selecting the Freedom SW 3000 Advanced Menu Selecting the Freedom SW 3000 from the Select Device MenuSelecting the Freedom SW 3000 Basic Menu To select the Freedom SW 3000 from the Select Device menuTo select the Freedom SW 3000 Advanced Menu Highlighting System on the Select Device MenuSelecting the Default Settings Returning to Freedom SW 3000 Basic MenuDevice Menu Mode DescriptionMenu Structure ModesBattery AC Input1AC Out Inverter Power ShareMenu Basic ChargerEqualize Range of valuesYes n/a Screen content Explanation of items displayed Want Equalization?Batt Type Clear FaultsRange of values Increment Default Batt SizeView Device Info Configure Inv/Chg Configure Inverter/ChargerMenu Advanced Basic MenuConfigure Inv/Chg Menu Sub-Menus# Chg Stages Cfg AC Limits Configure AC LimitsForce Charge Eqz VoltsAC Limits Configure AC Limits Risk of Damage to EquipmentHi AC Freq View Fault Log View Device Info View Device InformationView Warning Log Restore Defaults Restore DefaultsFault type Behavior TroubleshootingFault Types IntroductionTroubleshooting Troubleshooting Reference General Troubleshooting GuidelinesSection Number Troubleshooting Number Message Type Cause Solution To view a fault listTo view a message from a warning list Fault Messages To view a message from a fault listFault Number Message Fault Type Cause Solution AC Output Fault Number Message Fault Type Cause Solution Inverter Applications Resistive LoadsMotor Loads Battery Charging Reference Battery TypesRisk of Battery Damage Charge Algorithm Stages Three-Stage chargingTwo-Stage Charging Gel Charge Algorithm GraphFlooded Or wetOr wet Gel AGMFlooded Time Or wet Gel Battery Charger Interruption Inverter Specifications SpecificationsPhysical Specifications Charger SpecificationsSpecifications Fan Operation Transfer and General SpecificationsEnvironmental Specifications Regulatory ApprovalsInvert Power Derating vs. Ambient Temperature Charger ModeWarranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductReturn Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System Page Page Xantrex Technology Inc