Freedom SW 3000 Inverter/Charger Features

Supplied Accessories

1

2

3

4

Figure 6 Supplied Accessories

NOTE: If any of the supplied accessories are missing, contact Xantrex or any authorized Xantrex dealer for replacement. See “Contact Information” on page i.

Item

Description

1Two DC terminal covers are supplied to prevent accidental contact with the DC cable connectors after installation. The red cover is for the positive cabling terminal, and the black cover is for the negative cabling terminal.

2BTS, the Battery Temperature Sensor consists of:

Connector plugs into the BTS jack on the Freedom SW 3000.

Sensor cable is 25 feet (7.6 meters).

Sensor can be mounted on the side of the battery case or on the negative battery terminal.

NOTE: The BTS continuously measures the temperature of the battery and adjusts the charger output for a more accurate, temperature-compensated charge.

3Freedom Sine Wave remote panel (with 25-ft communications cable) is functionally similar to the Inverter Enable button on the unit’s front panel. It enables and disables the Freedom SW 3000’s inverter mode remotely. Connects to the REM jack on the Freedom SW 3000.

4Two sets of nuts and washers are used to secure DC cable ends to the DC terminals.

10

Freedom SW 3000 Owner’s Guide

Image 24
Contents Freedom SW Sine Wave Inverter/Charger Page About Xantrex Trademarks Exclusion for DocumentationDate and Revision Document Part NumberAbout This Guide Statement of HazardRelated Information Important Safety Instructions Electrical Shock HazardFire and Burn Hazard Explosion HazardPrecautions When Working With Batteries Precautions When Preparing to Charge Precautions When Placing the Inverter/ChargerExposure to Chemicals and Gases Hazard Risk of Damage to the INVERTER/CHARGERRegulatory Limitations on USEContents Page Page Page Introduction Materials ListPremium Power and Ease of Use About the Freedom SW Inverter/ChargerHow the Freedom SW 3000 Inverter/Charger Works InvertingCharging Typical Xanbus System Diagram Freedom SW 3000 Owner’s Guide Xanbus SystemProtection feature This feature… Comprehensive Electronic ProtectionFreedom SW 3000 Inverter/Charger Features Front and Side PanelsFront Panel Controls Status LEDs Compartment SideThough the transformer and power compartments Two variable-speed cooling fans are used to coolAC wiring compartment access panel with Freedom SWBattery temperature sensor BTS jack provides AC and DC Side PanelsNegative DC terminal connects to the negative AC Input 1, AC Input 2, and Inverter AC OutputSupplied Accessories Supplied AccessoriesOptional System Accessories and Network Components AccessoryNetwork Component Operating The Freedom SW Using the SCP 10 9 8On Start Up Exit buttonDown arrow button Up arrow buttonSystem Start-up Check Viewing the Firmware Revision Number To view the firmware revision numberOperating in Invert Mode To operate in invert mode from the front panelOperating Limits for Inverter Operation Operating in Charger Mode Charger Operation with Battery Temperature Sensor BTSOperating in Equalization Mode Risk of Damage to BatteriesEqualizing Batteries Terminating the Equalization ProcessRisk of Damage to DC Load Equipment To equalize your batteriesOperating Limits for Charger Operation Monitoring the Freedom SW 3000 Indicator Lights Faults and WarningsMonitoring Status Messages on the SCP System Modes OperatingTo return to Operating mode SafeSafe Mode To exit Safe mode and return to Operating modeConfiguration System Control PanelSystem Menu Map SCP System Menu Map Freedom SW 3000 Owner’s GuideViewing the System Screen Viewing the Select Device MenuTo view the Select Device menu Selecting the Freedom SW 3000 from the Select Device Menu Selecting the Freedom SW 3000 Basic MenuSelecting the Freedom SW 3000 Advanced Menu To select the Freedom SW 3000 from the Select Device menuTo select the Freedom SW 3000 Advanced Menu Highlighting System on the Select Device MenuSelecting the Default Settings Returning to Freedom SW 3000 Basic MenuMode Description Menu StructureDevice Menu ModesBattery AC Input1AC Out Power Share Menu BasicInverter ChargerEqualize Range of valuesYes n/a Screen content Explanation of items displayed Want Equalization?Clear Faults Range of values Increment DefaultBatt Type Batt SizeConfigure Inv/Chg Configure Inverter/Charger Menu AdvancedView Device Info Basic MenuConfigure Inv/Chg Menu Sub-MenusCfg AC Limits Configure AC Limits Force Charge# Chg Stages Eqz VoltsAC Limits Configure AC Limits Risk of Damage to EquipmentHi AC Freq View Fault Log View Device Info View Device InformationView Warning Log Restore Defaults Restore DefaultsTroubleshooting Fault TypesFault type Behavior IntroductionTroubleshooting Troubleshooting Reference General Troubleshooting GuidelinesSection Number Troubleshooting Number Message Type Cause Solution To view a fault listTo view a message from a warning list Fault Messages To view a message from a fault listFault Number Message Fault Type Cause Solution AC Output Fault Number Message Fault Type Cause Solution Inverter Applications Resistive LoadsMotor Loads Battery Charging Reference Battery TypesRisk of Battery Damage Charge Algorithm Stages Three-Stage chargingTwo-Stage Charging Charge Algorithm Graph FloodedGel Or wetOr wet Gel AGMFlooded Time Or wet Gel Battery Charger Interruption Specifications Physical SpecificationsInverter Specifications Charger SpecificationsSpecifications Transfer and General Specifications Environmental SpecificationsFan Operation Regulatory ApprovalsInvert Power Derating vs. Ambient Temperature Charger ModeWarranty and Return Information WarrantyWarranty and Return Information Disclaimer ProductReturn Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System Page Page Xantrex Technology Inc