| Operating The Freedom SW 3000 |
System | Viewing the Firmware Revision Number |
IMPORTANT: Review the “Important Safety Instructions” on page iv before operating the inverter/charger.
To test inverting and charging from the Freedom SW 3000 front panel:
1.Disconnect AC power from inverter input by opening the breaker or disconnect. Press the Inverter Enable button on the Freedom SW 3000. The Inverter On light illuminates.
2.Place a load on the inverter. For example, plug a 100 watt light bulb into an outlet that the inverter is powering and make sure it works. The inverter should run the load using battery power.
3.To test the charger, reconnect the AC input power to allow AC to the AC input. The AC/Charger On light should illuminate after a brief delay. Any AC loads previously powered by the inverter will also work at this time.
4.Remove the AC input power. The inverter/charger should transfer to invert mode immediately. (The transfer relay will make a clicking sound and the Inverter On light will illuminate.) Loads should continue to operate uninterrupted.
If any part of this test fails, determine the cause before using the unit. Consult the “Troubleshooting” chapter starting on page 45.
You may need to view the firmware revision number of the Freedom SW 3000 when troubleshooting the unit with authorized service personnel.
To view the firmware revision number:
1.On the Select Device menu, use the down arrow button to highlight System and press Enter.
The System Settings menu appears.
2.Press the down arrow button to highlight View Device info and press Enter.
The Device Info screen appears.
3.Press the down arrow button until the Freedom SW 3000 screen appears.
The number opposite “F/W Rev.” is the firmware revision number.
4.Press Exit to return to the System Settings menu.
15 |