Outback Power Systems OBX-IC2024S-120/60 owner manual Battery Wiring Examples for a 24-volt system

Page 12

6 V Battery Wiring Examples for a 24-volt system

-

-

-

6 V/200 amp-hours

6 V/200 amp-hours

6 V/200 amp-hours

-

6 V/200 amp-hours

DC DISCONNECT (FUSE OR CIRCUIT

BREAKER)

-

24-volt Inverter

SERIES: 200 amp-hours

-

-

-

-

6 V/200 amp-hours

6 V/200 amp-hours

6 V/200 amp-hours

6 V/200 amp-hours

 

SERIES STRING 1

 

SERIES STRING 1 CONNECTS TO

 

 

INVERTER’S POSITIVE TERMINAL

 

 

-

-

-

-

6 V/200 amp-hours

6 V/200 amp-hours

6 V/200 amp-hours

6 V/200 amp-hours

 

SERIES STRING 2

 

DC DISCONNECT (FUSE OR CIRCUIT

 

SERIES STRING 2 CONNECTS

BREAKER)

 

-

TO INVERTER’S NEGATIVE

 

 

TERMINAL

SERIES/PARALLEL: 400 amp-hours

24-volt Inverter

10

Image 12
Contents OBX-IC2024S-120/60 OutBack Power Systems Warranty SummaryContact Information DisclaimerTable of Contents OutBack Extreme Rugged Water Resistant Inverter/Charger Unit Dimensions Inverter MaintenanceParts Included Required ConductorsInitial Inspection Use and StorageImportant Battery Instructions Safety and Human FactorsMounting System Protection AC and DC Grounding RequirementsWire Connections DC WiringConnection Torque Battery Wiring SERIES/PARALLEL ExampleBattery Wiring Examples for a 24-volt system Battery Wiring Examples for a 24-volt system AC Wiring Connector PlatePage Powering UP Locking collarMATE2 System Controller and Display Mate AT a GlanceMounting the Mate 13504pHOT Keys INV Hot KeyAC in Hot Key KeyPress Three Times SUM Status Setup ADV Soft KeysSummary Screens Setup Screens FxmateSrch Input Main Down Grid GEN PortPG1 Sumry COM Main SETUP/MATE/SUMMARY Back Type Delay Roll SETUP/MATE/SUMMARYBack Type Delay Roll Clock CNT Glow PG2SETUP/MATE/SUM/TYPE Back INC DEC SETUP/MATE/SUM/TYPEBack INC DEC SETUP/MATE/SUMMARY Back INC DECCommunication Setup Screens SETUP/MATE/SUMMARY/TYPEBack INC DEC SETUP/MATE/SUMMARY/TYPE PG1 Sumry COM MainPG1 Sumry Comm Main Back Repoll PC DebugStatus Screens FX CC DC MainReading a Status Screen Status Meter Screens DefinitionStatus Battery Screens Pressing the Batt soft key brings up the first Batt screenStatus Error Screens Modes Meter Batt PG2 PG1 Error Warn PG3Status Warning Screens Status Disconnect Screens Disconnect ScreensInstallation Drawing Installation Check List OBX-IC2024S-120/60 Inverter/Charger Specifications Maximum AC Input Current Model Ampacity DC Breaker DC FuseInverter Default Values subject to change with upgrades VDC SystemMaintenance TroubleshootingYear Limited Warranty OutBack Extreme Inverter/Chargers2008-01-07 Address for warranty certificate Equipment OwnerPage Corporate Headquarters European Sales Office